background image

TRT-BA-AIROZON®14ECO-TC2020-16-002-EN

AIROZON

®

 14 ECO

EN

ORIGINAL INSTRUCTIONS

OZONE GENERATOR

Summary of Contents for 1180000090

Page 1: ...TRT BA AIROZON 14ECO TC2020 16 002 EN AIROZON 14 ECO EN ORIGINAL INSTRUCTIONS OZONE GENERATOR...

Page 2: ...ore starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings...

Page 3: ...rators The device uses ozone for air purification It is a gas that due to its oxidative characteristics can cause severe health damage if inhaled Direct exposure to and intake of ozone is toxic for hu...

Page 4: ...mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable out of the mains socket Warning Dangers can occur at the device when it is used by untrained people in an unpro...

Page 5: ...UV radiation It is these atoms that can react with the oxygen molecules to form ozone O3 In case of a high solar irradiation ozone forms involving other air pollutants The nitrogen oxides NOx from au...

Page 6: ...he mains plug while pulling the power cable out of the mains socket If the device was previously in use wait until the end of the calculated regeneration period see Shutdown chapter before transportin...

Page 7: ...ground Position the device as close as possible to the centre of the room to ensure an optimum air circulation When positioning the device keep a sufficient distance to heat sources Make sure that no...

Page 8: ...t an odour neutralization air purification Warning Risk of injury caused by inhalation of ozone The following symptoms could be indicative of poisoning or an irritation caused by ozone eye irritations...

Page 9: ...s proteins with nitrogen and sulphur vomit 360 720 Please contact the Trotec customer service if you like to use the device for disinfection purposes Switch off Warning Risk of injury caused by ozone...

Page 10: ...ling the power cable out of the mains socket Warning Risk of injury caused by inhalation of ozone After the device has stopped operating wait until the end of the calculated regeneration period see Sh...

Page 11: ...aning agents Make sure that no water can enter or remain inside the housing Replacing a fuse The fuse must be replace once it is defective or no longer works correctly Please proceed as follows to rep...

Page 12: ...V Frequency 50 Hz Max nominal current 0 8 A Max power input 180 W Ozone output 7 g h 14 0 g h Air flow rate 168 m h Sound pressure level at a distance of 3 m 45 dB A Dimensions depth x width x height...

Page 13: ...EN 13 Ozone generator Airozon 14 ECO Circuit diagram L N E TIMER FAN Ozone Generator Power 1 FU Ozone Generator Power 2 Indicator light...

Page 14: ...spare parts differ from those describing the positions of the components mentioned in these instructions 1 2 3 4 5 6 7 8 9 10 11 No Spare part No Spare part 1 handle 7 Ozone power supply 2 cover 8 Tim...

Page 15: ...he contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 44534 Declaration of conformity in accordance with the EC Machinery Directive...

Page 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...