Ozone generator Airozon 60000

Make sure that no curtains or other objects interfere with
the air flow.

Do not position the device near inflammable substances
and gases.

Make sure that the air inlet and outlet are not obstructed.

Make sure that the device is protected from spray water.

Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.

Make sure that extension cables are completely unrolled.

The room temperature should be approx. 5 °C higher than
the usual room temperature.

Connecting the power cable

Insert the mains plug into a properly secured mains socket
located outside of the room to be cleaned. This enables
you to switch the device off in case of an emergency
without having to access the room.

Operation

Note

Avoid open doors and windows.

Operating elements

8

9

10

6

6

Timer

8

10

6

8

11

12

14

13

No.

Designation

Description

6

On/off

 button

Switching the device on or off

I

: Switching the device on

0

: Switching the device off

Is illuminated when the device
is switched on.

8

Operating hours counter Indicates the operating time

9

Operating control lamp

Illuminated when the
device is in operation

Emits a beep sound in
intervals

10

Timer

Set treatment duration: 
0–100 hours
(ozone generation
begins 1 minute after
activation)

11

Display

Displays the set time of the
timer

12

PROG

 button

Selecting the setting mode and
the individual display
indications

13

RESET (+)

 button

Resetting to start time of
timer

(

+

) selection mode =

increase time

14

START/STOP (-)

 button

Starting and stopping the
timer

(

-

) selection mode =

decrease time

Switch-on / switch-off

Warning

Risk of injury caused by ozone!
Exit the room as soon as you have switched the device
on so as to prevent contact with ozone.

Warning

Risk of injury caused by ozone!
The device is not a hermetically sealed system. There
is always the risk of ozone emitting from the device.
If possible, connect the cable of the device to a socket
located outside of the room with the device. In the
event of an emergency, you can pull out the power
cable from the socket without having to enter the
room.

1. Press the 

on/off

 (6)button to switch the device on.

ð

The operating control lamp (9) is illuminated.

2. Press the 

on/off

 switch (6) again to switch the device off.

Summary of Contents for 1.180.000.114

Page 1: ...TRT BA AIROZON60000 TC2020 30 001 EN AIROZON 60000 EN ORIGINAL INSTRUCTIONS OZONE GENERATOR ...

Page 2: ...owing link Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be ...

Page 3: ...mages surfaces misted up with condensation Particularly observe this for all uncoated metals and plastics Specific safety warnings for the operation of ozone generators The device uses ozone for air purification It is a gas that due to its oxidative characteristics can cause severe health damage if inhaled Direct exposure to and intake of ozone is toxic for humans animals and plants For this reaso...

Page 4: ...e Behaviour in the event of an emergency 1 In an emergency disconnect the device from the mains feed in Hold onto the mains plug while pulling the power cable out of the mains socket 2 In an emergency only enter the room to be cleaned wearing a respirator mask fitted with ozone filter and ensure a sufficient supply of fresh air 3 Do not reconnect a defective device to the mains Information about t...

Page 5: ...s the so called habituation effect After only a brief period of time spent in an ozone polluted environment we become so acclimated to the smell that we go noseblind The impact of ozone on human beings The sensitivity to ozone depends on its concentration and varies for each individual Ozone is an oxidative irritant gas affecting eyes nose pharynx and lungs even at low concentrations The mucous me...

Page 6: ...nditions Dry and protected from frost and heat With a cover to protect it from invasive dust if necessary Assembly and start up Scope of delivery 1 x Manual 1 x Device 1 x Power cable Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it durin...

Page 7: ...Is illuminated when the device is switched on 8 Operating hours counter Indicates the operating time 9 Operating control lamp Illuminated when the device is in operation Emits a beep sound in intervals 10 Timer Set treatment duration 0 100 hours ozone generation begins 1 minute after activation 11 Display Displays the set time of the timer 12 PROG button Selecting the setting mode and the individu...

Page 8: ...the START STOP button 14 is actuated again or if the device is switched off by means of the mains switch or if the power supply is interrupted This function is intended for operating the device with an external timer e g Trotec Zerozon 200 Resetting the timer You can reset the timer by simultaneously and briefly pressing the PROG 12 RESET 13 and START STOP 14 buttons The timer will switch back to ...

Page 9: ... sulphur vomit 360 720 Please contact the Trotec customer service if you like to use the device for disinfection purposes Shutdown Warning Risk of injury caused by ozone Have especially trained staff check the ozone concentration before entering the room and permitting others to access it Warning Wear a respirator mask with ozone filter when you check whether the ozone concentration has decreased ...

Page 10: ...lling the power cable out of the mains socket Warning Risk of injury caused by inhalation of ozone After the device has stopped operating wait until the end of the calculated regeneration period see Shutdown chapter to make sure that the ozone concentration has fallen below the stipulated value before performing maintenance and cleaning work Care and maintenance must be performed on a regular basi...

Page 11: ...th Do not use any solvent containing or aggressive cleaning agents Make sure that no water can enter or remain inside the housing replace air filter 1 Loosen the screws at the device front 2 Remove the cover of the air filter 15 3 Remove the air filter 16 from the device 15 6 16 4 Insert a new air filter into the device 5 Put the cover of the air filter 15 on the device and fasten it by means of t...

Page 12: ...12 EN Ozone generator Airozon 60000 Wiring diagram ...

Page 13: ...EN 13 Ozone generator Airozon 60000 ...

Page 14: ...cross DIN 7985 M 4 x 6 V2A 14 swivel castor 3 Screw Liko cross DIN 7985 M 5 x 50 15 Ozone plate 4 Screw Liko cross DIN 7985 M 4 x 8 16 Electrical plate 5 Washer DIN 522 10 5x25x4 17 Bottom housing 6 Hexagon screw DIN 933 M 10 x 35 18 Cover for maintenance work 7 Screw N_933_ changed 19 Filter box 8 Saddle washer 20 1 phase fan 9 Washer Ø22 x Ø5 3 x H6mm black 21 Handle 10 Washer DIN 9021 Ø5 3xØ15x...

Page 15: ...bing the positions of the components mentioned in these instructions 1 Hexagon screw DIN 933 M 10 x 25 4 Spacer sleeve Ø5 3xØ10xL8 2 Hexagon socket countersunk screw DIN 7991 M 4 x 20 5 Finger protection 78129 2 4039 D 210 3 Fan K3G250AT3972 6 Self adhesive cellular rubber sealing tape w h 19 2mm l 1520mm ...

Page 16: ...ier 02437 01 13 Sealing plug Ø19xØ16xØ11x1 5xL8 4 Cover for electrics K electrics cover 02431 01 14 Washer DIN 125 A Ø4 3 VA 5 Porcelain terminal 3 phase 15 Screw Liko cross DIN 7985 M4 x 12 VA 6 End plate FAP 2 5 4 YE 16 Hexagon nut self locking DIN 985 M4 VA 7 Feed through terminal FRK 2 5 4A BG 17 Slotted set screw with cup point DIN 916 M 4 x 12 8 Feed through terminal FRK 2 5 4A GNYE 18 Screw...

Page 17: ...ut the contents of the declaration of conformity The signed declaration of conformity can be found at Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part 1 Section A Herewith we Trotec GmbH declare that the machinery designated below was developed constructed and produced in compliance with the requirements of the EC Machinery Directive in the version 2...

Page 18: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: