TRT-BA-AIRGOPRO8-TC220502TTRT01-001-EN

AIRGOPRO

®

 8

EN

ORIGINAL INSTRUCTIONS

ODOUR NEUTRALISER

Summary of Contents for 1.180.000.020

Page 1: ...TRT BA AIRGOPRO8 TC220502TTRT01 001 EN AIRGOPRO 8 EN ORIGINAL INSTRUCTIONS ODOUR NEUTRALISER...

Page 2: ...n the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or...

Page 3: ...ke sure that the suction side is kept free of dirt and loose objects This odour neutraliser generates very small amounts of ozone max 0 05 ppm sqm which are harmless to health Reduce the ozone output...

Page 4: ...sk of injury caused by inhalation of ozone During the air purification cycle small amounts of ozone O3 may be produced If necessary gradually reduce the production or take the device out of operation...

Page 5: ...the treatment the oxygen contained in the room air is converted so that existing odour molecules are broken down by means of oxidation The device also produces very small amounts max 0 05 ppm m3 of oz...

Page 6: ...pletely remove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up When positioning the device observe th...

Page 7: ...time 14 Multiplier display Indicates the set multiplier 15 Rotary switch for scale Setting the time scale 16 Rotary switch for multiplier Setting the multiplier in the following increments 0 0 5 0 1 0...

Page 8: ...ry switch for the multiplier 16 to determine whether the indicator scale 13 shall be used for 5 or 50 time units After the expiration of this time the device will switch off automatically The timer is...

Page 9: ...set time to elapse before making a new adjustment 8 Air out the room after each interval and after each readjustment The temperature is also a crucial factor for successful treatment Heat increases t...

Page 10: ...age Check the on site fusing Switch the fuse back on or have a defective fuse replaced by a specialist company Wait for 10 minutes before restarting the device If the device is not starting have the e...

Page 11: ...screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects...

Page 12: ...ng the maintenance interval Device operation takes place frequently and several hours at a time on many days per month in excessively dirty surroundings in humid rooms Regardless of the described oper...

Page 13: ...ctrode The electrode may be cleaned whilst built in 1 Prior to cleaning check the electrode for cracks or breakage Damaged components must not be used 2 Clean the electrode using a lint free dry or da...

Page 14: ...14 EN odour neutraliser AirgoPro 8 Circuit diagram...

Page 15: ...itions of the components mentioned in these instructions No Designation No Designation 1 Operating hours counter 8 Intensity level controller 2 Connection plug incl mains plug 9 On off mains switch 3...

Page 16: ...ind out about other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equ...

Page 17: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...