Chapter 1
Tropos 7320 Router Installation Guide
26
Connecting to AC Power (Category C)
The AC power connections for a Category C AC power source are shown in
FIGURE 15
Connecting Category C AC Power
Connect an AC power source
1.
Verify that the service voltage is 100-480 VAC 50/60 Hz.
2.
Verify that power is turned off on the designated circuits.
3.
Install 1/2-inch liquid-tight conduit from the building entrance point to within 3 feet of the
outdoor system.
4.
Run 3-wire AC service through the conduit.
5.
Connect the conduit to a junction box. The conduit and junction box must be IEEE/ANSI
compliant and suitable for outdoor use.
Note
Data and power must never be enclosed in the same conduit.
6.
Connect the AC cable to the router and tighten the nut hand-tight. See
7.
Connect the router to a 100-480 VAC 50/60 Hz CAT C power source.
8.
Reenergize the circuit and confirm that power to the router comes on.
trp_106
AC power
from meter
AC wiring in
junction box
To power
source
Green wire
Wire nuts
White wire
Black wire
To outdoor unit