tropitone 401600RCT Installation And Operating Instructions Manual Download Page 7

R9T15FIRE 

Page 7 of 16 

Rev. D 04JAN19 

 

 
 

 

 

FIRE MEDIA INSTALLATION

 

 

 

Please follow the instructions below to add the finishing touch to your Fire Pit. Your Fire Pit needs fire 
media  in  order  to  get  the  proper  flame  characteristics  from  the  burner  assembly.   The  media can 
be  decorative  fire  glass, fire pebbles, lava rock or  other  fire  media  specifically  designed  for outdoor 
fire  pits  and  fireplaces. 

Fire  media  is  not  included  with  Fire  Pit  and  must  be  purchased 

separately. 

 

              

DANGER 

Do not block the pilot area or blow out box. The burner may be 

lightly 

covered by fire 

media. Proper air flow is required in order to prevent suffocation and possible gas buildup. Incorrect 
media installation will cause the pilot flame to suffocate and turn off the fire pit or delay main burner 
ignition.  If  the  main  burner  does  not  ignite  quickly,  gas  can  build  up  in  the  burner  tray  and  ignite 
violently. 

Ignition  of  gas  which  has  built  up  can  create  an  unsafe  condition,  and  may  cause 

injury  or  death,  and  may  damage  personal  property.  The  deeper  your  decorative  glass,  fire 
pebbles or lava rock, the more risk of reducing or smothering the flame from the burner

 

Decorative Glass or Fire Pebbles Application 

 

1) 

Install your Fire Pit per instructions. 

 

2) 

Apply decorative glass or fire pebbles just 

deep enough to cover bottom of pan. Make sure 
you do NOT cover the Blow Out Box. 
 

Blow Out Box 

 

 

3)

 Blow Out Box: Do not cover blow out box vents 

or opening with decorative glass or fire pebbles. 
Incorrect media installation will cause the pilot 
flame to suffocate and turn off pit or delay main 
burner ignition. 
 
 
 
 
 
 
 
 

DO NOT COVER VENTS! DO NOT COVER PILOT 
OPENING!

 

 
 

Lava Rock Only Application* 

 

1)

 Install your Fire Pit per instructions. 

 

2) 

Apply lava rock ONLY deep enough to cover 

ring and pan- 

no more than ½” above the burner. 

 

 

 

3) 

Blow Out Box: Do not cover vents with lava 

rock- leave open. Do not allow any rock to block 
flame opening. 
 
 
 

Blow Out Box 
 

 
 
 
 
 
 
 
 

4)

 Blow Out Box: Do not cover blow out box vents 

or opening with lava rock or glass. Incorrect media 
installation will cause the pilot flame to suffocate 
and turn off pit or delay main burner ignition. 

 
 
 

*

Lava rock not available from Tropitone.

 

 

 

Summary of Contents for 401600RCT

Page 1: ...e shall not be stored in the vicinity of this or any other appliance DANGER FIRE OR EXPLOSION HAZARD If you smell gas Shut off gas to the appliance Extinguish any open flame If odor continues leave the area immediately After leaving the area call your gas supplier or fire department Failure to follow these instructions could result in fire or explosion which could cause property damage personal in...

Page 2: ...rvicing this equipment Some information listed in this manual has headings which have been highlighted in order to assist you to identify critical pieces of information They can be identified as follows WARNING Contains information critical to the safe installation and operation of the unit DANGER Contains information critical to the safety of you your personal property and others around this prod...

Page 3: ...Burning gas both Natural and LP produces fumes which can be dangerous if inhaled Always insure there is proper ventilation when using any fire products DANGER All Fire Pits are designed and intended for outdoor use only Never install or operate indoors Burning gas both Natural and LP produces very high temperatures Always insure all combustible materials are kept far enough away to prevent acciden...

Page 4: ...pe that is approved for use with all types of gas Apply to all male pipe fittings only DO NOT use on FLARED fittings Be sure all joints are tightened securely before lighting WARNING Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required as necessary...

Page 5: ...sted overfilling prevention device and 3 Provided with a cylinder connection device compatible with the connection for the appliance IMPORTANT The LP Gas tank must be secured in the fire pit For 401600RD 401601RD 401601SQ and 401701RCT bases place the tank in the tank retaining ring For 401600RCT base slide horizontal LP gas tank along middle support until the back mounting bracket of the tank hit...

Page 6: ...r or other conditions NEVER use any Fire Pit which has any components including the gas hose or gas tank connector damaged in any way If you find any damage turn off the valve on the gas tank and call a licensed repair technician to replace damaged components Replace any damaged items with components that have the exact same ratings WARNING Before you turn on your Fire Pit for the first time you m...

Page 7: ... or death and may damage personal property The deeper your decorative glass fire pebbles or lava rock the more risk of reducing or smothering the flame from the burner Decorative Glass or Fire Pebbles Application 1 Install your Fire Pit per instructions 2 Apply decorative glass or fire pebbles just deep enough to cover bottom of pan Make sure you do NOT cover the Blow Out Box Blow Out Box 3 Blow O...

Page 8: ... lighter or match to light the pilot located in front of the igniter box 5 Turn knob counter clockwise left to light main burner NOTE If fails to light rotate knob to center position wait 5 minutes for gas to clear repeat Steps 4 5 If goes out repeat Steps 4 5 6 Once Fire Pit has ignited DO NOT leave unattended FIRE PIT SHUTDOWN 1 Turn off fire pit by slightly pressing and turning valve knob clock...

Page 9: ...t Retaining M1 for Gas Valve R02NU501 3 Gas Valve R18VL100 4 3 8 Flare x 3 8 MIPT R18CO108 5 Gas Hose with Regulator 3 8 x 12 Long Gas Hose with Regulator 3 8 x 36 Long R18FH100 R18FH103 6 Gas Plumbing Support Weldment WSL30RFPGVS Gas Plumbing Support Weldment not shown W401767FPSGV 7 Nipple 3 8 x 1 5 R15SP101 8 1 2 x 1 2 FIP 90 R15CO101 9 Gas Flex Line 24 x 1 2 R15SP100 ...

Page 10: ... 6 Stamped Burner STMPBA6 12 Stamped Burner not shown STMPBA12 4 Nut 1 2 Stainless Steel R02NU500 5 Pilot Thermocouple Assembly R19TC101 6 Washer 1 500 OD x 890 ID x 090 R02WA880 7 Nipple 1 2 Stainless Steel R15CO106 8 Elbow 1 2 FPT x 3 8 FPT R18CO120 9 3 8 LP Gas Air Mixer R18VL106 3 8 LP Gas Air Mixer R18VL101 10 3 8 FPT TEE R15CO109 11 1 2 Flare x 3 8 MIP Flare Half Union R18CO107 12 3 8 MPT x ...

Page 11: ... 3 Gas Valve R18VL100 4 Brass Adapter 3 8 R15CO111 5 Elbow 3 8 M x 3 8 F R15CO100 6 3 8 Flare x 3 8 MIPT R18CO108 7 Gas Hose with Regulator 3 8 x 12 Long Gas Hose with Regulator 3 8 x 36 Long R18FH100 R18FH103 8 Gas Plumbing Support Weldment W401442FPSGV Gas Plumbing Support Weldment Gas Plumbing Support W401443FPSGV R15MS310 9 Nipple 3 8 x 1 5 R15SP101 10 1 2 x 1 2 FIP 90 R15CO101 11 Gas Flex Lin...

Page 12: ...r STMPBA243 5 Electrical Insulation Silicone Fiberglass R19NS100 6 Blow Out Box Assembly R19NT107 7 Pilot Thermocouple Assembly R19TC101 8 Washer 1 500 OD x 890 ID x 090 R02WA880 9 Nipple 1 2 Stainless Steel R15CO106 10 Elbow 1 2 FPT x 3 8 FPT R18CO120 11 3 8 LP Gas Air Mixer R18VL101 12 3 8 FPT TEE R15CO109 13 3 8 MPT x 1 8 FPT Reducing Bushing R15CO110 14 1 2 Flare x 3 8 MIP Flare Half Union R18...

Page 13: ...bly connection beneath the burner tray When converting from LP to Natural gas installer must remove the supplied gas hose and LP regulator and install the correct regulator for Natural gas The regulator must limit the supply as specified below Natural Gas Supply Pressure Minimum 5 0 WC water column Maximum 10 0 WC Operating Pressure Minimum 5 0 WC Maximum 7 0 WC Remove the LP Gas tank hose from th...

Page 14: ... this appliance is intended to use on all male threads EXCEPT compression threads Never apply thread tape of compound to compression threads Beneath the Burner tray locate the Gas Air Mixer in the plumbing Remove the LP Gas Air Mixer and replace with the Natural Gas Orifice LP Gas Air Natural Mixer Gas Orifice ...

Page 15: ...ev D 04JAN19 Once your Fire Pit has been converted to Natural Gas please locate the small silver label and remove the bottom strip Place this strip over the section indicated above on the large label located on the inside door ...

Page 16: ...e Pit has been tested and approved in accordance with ANSI Z21 97 by ICC ES Listing No PMG 1114 Tropitone Furniture Co Inc 5 Marconi Irvine Ca 92618 949 951 2010 www tropitone com 1401 Commerce Blvd Sarasota Fl 34243 Tropitone Furniture Co Inc 2019 ...

Reviews: