Tronair 14-6895-6000 Operation & Service Manual Download Page 5

Model:  14-6895-6000 

Aircraft Strut Pressure Gauge 

 

09/2000 | Rev. OR 

Page | 2 

 

3.0 

ASSEMBLY INSTRUCTIONS 

NOTE:  It is recommended Nitrogen servicing procedure should be accomplished in conjunction with Tronair Service 
Regulator/Model:  14-6804-6000. 

1.  Reference 

Figure 1

 during the following steps. 

2.  Ensure (D) Nitrogen Supply Valve is closed (OFF). 
3.  Connect (H) Pressure Regulator to Nitrogen supply (not included) if not already connected. 
4.  Decrease (H) Pressure Regulator to the minimum pressure setting; the regulator adjustment knob is a rotating type. 

Clockwise rotation of the knob increases pressure and counter-clockwise rotation decreases pressure. 

5.  Turn valve handle clockwise to close (A) Air Bleeder Valve. 
6.  Connect (F) Hose Coupling to (G) Pressure Valve. 
7.  Ensure (C) Nitrogen Charging Valve is in closed position. (Refer to Aircraft Maintenance Manual) 
8.  Connect (B) Hose Coupling to (C) Nitrogen Charging Valve. 
9.  Open (C) Nitrogen Charging Valve. (Refer to Aircraft Maintenance Manual) 

10. 

Turn handle clockwise on (B) Hose Coupling to depress valve core in (C) Nitrogen Charging Valve. 

11. 

Open (D) Nitrogen Supply Valve. 

12. 

Adjust (H) Pressure Regulator until (E) Pressure Gauge reads desired pressure. 

3.1 

DISASSEMBLY 

1.  Reference Figure 1. 
2.  Close (C) Nitrogen Charging Valve. (Refer to Aircraft Maintenance Manual) 
3.  Turn handle counter-clockwise on (B) Hose Coupling to release valve core in (C) Nitrogen Charging Valve. 
4.  Close (D) Nitrogen Supply Valve (OFF). 
5.  Bleed off any excess Nitrogen in gauges and lines by turning valve handle counter-clockwise to open (A) Air Breeder 

Valve. 

6.  Disconnect Pressure Gauge Assembly from strut and Regulator Assembly. 
 

4.0 

PARTS LIST 

Reference following page for ordering information of Replacement Parts and Kits. 
 
When ordering Replacement Parts/Kits, please specify Model & Serial Number of your product. 

FIGURE 1 

Summary of Contents for 14-6895-6000

Page 1: ...N SERVICE MANUAL Tronair Inc Phone 419 866 6301 800 426 6301 1 Air Cargo Pkwy East Web www tronair com Swanton OH 43558 Email sales tronair com Model 14 6895 6000 Aircraft Strut Pressure Gauge 09 2000...

Page 2: ...REVISION DATE TEXT AFFECTED OR 09 2000 Original release...

Page 3: ...AFETY INSTRUCTIONS 1 1 1 GENERAL 1 1 2 SAFETY 1 2 0 OPERATION OF NITROGEN STRUT SERVICE KIT 1 2 1 TRAINING 1 2 2 GENERAL SAFETY REQUIREMENTS 1 2 3 WARNINGS AND CAUTIONS 1 3 0 ASSEMBLY INSTRUCTIONS 2 3...

Page 4: ...ve that all inspection maintenance testing and servicing of nitrogen system components be done by trained and qualified personnel using approved procedures 2 0 OPERATION OF NITROGEN STRUT SERVICE KIT...

Page 5: ...efer to Aircraft Maintenance Manual 8 Connect B Hose Coupling to C Nitrogen Charging Valve 9 Open C Nitrogen Charging Valve Refer to Aircraft Maintenance Manual 10 Turn handle clockwise on B Hose Coup...

Page 6: ...ation RMA number will be issued for reference purposes on any shipping documents Failure to obtain a RMA in advance of returning an item will result in a service fee A decision on the extent of warran...

Page 7: ...ssure gauge is to be calibrated annually or as required Reference Appendix I Item Part Number Description Qty 1 HC 1862 Gauge 1 500 psi Pressure Calibrated 1 2 H 2153 Boot Gauge 1 3 PC 1074 Cap High P...

Page 8: ......

Page 9: ...APPENDIX I Instrument Certification Notice...

Page 10: ......

Page 11: ...perform the calibration check The due date for re calibration of the instrument should be based upon the date the instrument was placed in service in your facility Re calibration should be done on a p...