background image

Technical Specifications

Specifications are subject to change  without notice

Typical, for T=20degC, Zin=Zout =75ohms

User Manual – TLE35128 

MHz
MHz

Gain 

dB

Gain Response Flatness

dB

Gain Control 

dB

Cable Slope Control 

dB

Interstage Equalizer Control 

dB 

RF Test Points 

dB 

Distortions, EN50083-3

CTB

dBc

CSO

dBc

XMOD

dBc

Distortions, EN50083-3

CTB

dBc

CSO

dBc

XMOD

dBc

Distortions, 79 Channels 

CTB

dBc

CSO

dBc

XMOD

dBc

Distortions, 79 Channels 

CTB

dBc

CSO

dBc

XMOD

dBc

Noise Figure

dB

Group Delay (with 42/54 Diplex Filters)

48.25 - 52.83 MHz

nSec.

55.25 - 58.83 MHz

nSec.

61.25 - 64.83 MHz

nSec.

Other 

nSec.

85-86 MHz

nSec.

Return Loss (Input & Output)

dB

TLE35128

Technology 

GaAs - Hybrid Power Doubler 

Model 

Remote 30-90VAC, cascadable

Bandwidth-Forward

 (Plug-in Diplex Filters)

47-862 / 54-862 / 85-862

Powering 

Bandwidth-Reverse 

5-30 / 5-42 / 5-65

F

o

r

w

a

r

d

 

P

a

t

h

35

+/-

 0.75

 0..-20 , continious , input

 0..-20 , continious, input

Plug-in   /  0, 2, 4, 6, 10, 12, 14, 20

-20dB, input & output 

Cenelec 42 Ch. -60dBc, Flat output

112
115
108

Cenelec 42 Ch. -60dBc, 10dB interstage slope

114
117
110

-16

47dBmV Flat Output 

10dB Interstage Slope (54-862MHz), ref 47dBmV

-72
-68
-61

-78
-74
-65

6

max. 30
max. 30
max. 15

max. 4

max. 10

Gain 

dB

Gain Response Flatness
Gain Control - Input

dB

Gain Control - Output

dB

Cable Slope Control - Output

dB 

RF Test Point

dB 

Distortion 4 Channel 

CTB

dBc

CSO

dBc

XMOD

dBc

Return Loss (Input & Output)

dBuV

Group Delay (with 42/54 Diplex Filters)

5-6 MHz

nSec.

13-14 MHz

nSec.

29-30 MHz

nSec.

41-42 MHz

nSec.

64-65 MHz

nSec.

Noise Figure

dB

AC Input 

VAC

Power Consumption 

W

Hum Modulation 

dB

Surge Withstand 
Port Current 

A

AC Power Direction 
RFI Isolation (5-1000MHz)

dB

Temperature

degC

Water Immersion 
Dimensions

mm 

Weight 

kgs

R

e
v
e

r
s

e

20dB 

+/-

 0.50

max. 20
max. 30

40dBmV flat output 

-61
-86

Fixed Value Plug-in   / 0, 2, 4, 6

 0..-20 , continious

Fixed Value Plug-in   / 0, 2, 4, 6, 8, 10

7

max. 20

G
e
n

e

r

a

l
 

Input and Output Ports 

over coaxial network, 30-90VAC 

14.5W

(with reverse amplifier module- 1.3W)

15psi for 10 seconds @ 20degC

<-100

-100 @ 10A

@all ports , IEEE C62.41 Cat B3 (6kV,3kA)

IN, OUR or THRU 

-40 to +55

190*170*75

1.6

max. 50

max. 4

-78
-16

-20dB,  output

Standard 5/8''-24UNEF stainless steel bushing

Typ=10 , Max=15