The following codes relate to on-screen warnings (visual) that the XD One will display when a fault is
encountered during normal operations. Faults will be displayed using the on-device LEDs and are
described in the table below.
Any faults encountered during device operation are captured by the on-device log for offline analysis
as required.
No.
Sequence
Fault Name
Fault Description
Fault Check
1
Internal memory
corruption
A corruption in the XD
One’s internal memory
was detected. Loss of
data readings has
occurred, or readings
cannot be recovered.
The device will
automatically format
its memory and
continue its
operation.
2
Internal memory
full
The XD One’s internal
memory is full.
Download and clear
the devices data,
event and alarm logs.
3
Particulate
sensor data error
The data received from
the particulate sensor was
found to be corrupt. The
XD One will ignore this
reading, log the event and
continue its operation.
If this error occurs more
than 4 times, the XD One
will alert the user and
enter an error state.
Contact Trolex or
approved distributor.
4
Device settings
corruption
A corruption in the XD
One’s device settings was
detected.
The device will
automatically revert
to factory defaults
and continue its
operation.
5
Particulate
sensor electronic
failure
The XD One has detected
an electronic hardware
failure of the particulate
sensor.
The XD One will alert the
user and enter an error
state.
Contact Trolex or
approved distributor.
6
Internal memory
electronics
failure
The XD One has detected
an electronic hardware
failure of the internal
memory. The XD One will
alert the user and enter an
error state.
Contact Trolex or
approved distributor.