AWC7813 motion controller user manual
WWW.SZTROCEN.COM
73
【
Go Origin After reset
】
(for details, please refer to
Go Origin After reset
)
, it will stop at the origin position after
reset. If it is not reset, the zero position will not be found, and
the machine may exceed the format when working.
Z AutoReset
If the Z-axis automatic reset is required when power is on, it
needs to be turned on. After it is turned on, the Z-axis drives
the laser head to move down and stops when it hits the Z-limit
switch.
3.16.5 HardLimit Settings
Please refer to the description and wiring of the limit signal input port
Limit signal input port
.
Generally, setting the format size can control the operating range of the laser
head. If you need to turn on the hardware limit, the steps are as follows:
In
interface, click
【
Menu
】 → 【
Manufacturer
Parameters Settings
】→【
HardLimit Settings
】
to open.
Figure3-16-5 Hardlimit settings