background image

12

digital protocol (see previous table).

Note: 

Please note that not all functions are possible in all 

digital protocols. Several settings for functions, which are 

supposed to be active in analog operation, can be done 

under mfx and DCC. 

Notes on digital operation 

•   The operating instructions for your central unit will give 

you exact procedures for setting the different parame-

ters. 

•   The values set at the factory have been selected for mfx 

in order to guarantee the best possible running characte-

ristics.  

Adjustments may have to be made for other operating 

systems. 

•  The setting done at the factory does not permit operation 

with opposite polarity DC power in the braking block. 

If you want this characteristic, you must do without 

conventional DC power operation (CV 29/Bit 2 = 0). 

mfx Protocol
Addresses 

•   No address is required; each decoder is given a one-

time, unique identifier (UID).

•   The decoder automatically registers itself on a Central 

Station or a Mobile Station with its UID.

Programming 

•   The characteristics can be programmed using the 

graphic screen on the Central Station or also partially 

with the Mobile Station.

•   All of the Configuration Variables (CV) can be read and 

programmed repeatedly.

•   The programming can be done either on the main track or 

the programming track.

•   The default settings (factory settings) can be produced 

repeatedly.

•   Function mapping: Functions can be assigned to any of 

the function buttons with the help of the 60212 Central 

Station (with limitations) and with the 60213/60214/60215 

Central Station (See help section in the Central Station).

DCC Protocol
Addresses 

•   Short address – long address – multiple unit address

•   Address range: 

 

1 - 127 for short address and multiple unit address,  

1 - 10239 for long address 

•   Every address can be programmed manually.

•   A short or a long address is selected using the CVs.

•   A multiple unit address that is being used deactivates the 

standard address. 

Programming

•   The characteristics can be changed repeatedly using the 

Configuration Variables (CV).

•   The CV numbers and the CV values are entered directly.

•   The CVs can be read and programmed repeatedly. (Pro

-

gramming is done on the programming track.)

•   The CVs can be programmed in any order desired. (Pro

-

gramming can be done on the main track PoM). The PoM 

Summary of Contents for 22623

Page 1: ...Modell der Diesellokomotive BR 260 22623 D GB F USA NL...

Page 2: ...2...

Page 3: ...rameter Register 15 Service and maintenance 26 Spare Parts 30 Sommaire Page Informations concernant la locomotive r elle 5 Remarques importantes sur la s curit 16 Information importante 16 Mode multip...

Page 4: ...remote radio controls A signal light on both sides of the engineer s cab indicates unmanned operation Information zum Vorbild Die Baureihe 260 261 der Deutschen Bundesbahn DB ist eine dreiachsige die...

Page 5: ...ommande Des deux c t s du poste de conduite un feu de signal indique le service vide Informatie van het voorbeeld De serie 260 261 van de Deutsche Bundesbahn is een drieassige dieselhydraulische lokom...

Page 6: ...fang ist nur unter Trix Systems DCC und unter mfx verf gbar Eingebaute fahrtrichtungsabh ngige Stirnbeleuchtung Im Digitalbetrieb schaltbar Befahrbarer Mindestradius 360 mm Multiprotokollbetrieb Analo...

Page 7: ...einer Central Station oder Mobile Station mit seiner UID automatisch an Programmierung Die Eigenschaften k nnen ber die grafische Oberfl che der Central Station bzw teilweise auch mit der Mobile Stati...

Page 8: ...tellt werden 14 bzw 28 126 Fahrstufen einstellbar Automatisches Bremsen CV 27 Wert 16 Alle Funktionen k nnen entsprechend dem Funktions mapping geschaltet werden Weitere Information siehe CV Tabelle D...

Page 9: ...Ger usch Horn Funktion 3 Funktion f3 Funktion f3 Telex hinten Funktion 4 Funktion f4 Funktion f4 ABV aus Funktion 5 Funktion f5 Funktion f5 Spitzensignal F hrerstand 2 aus Funktion 6 Funktion f6 Funk...

Page 10: ...CV 29 Bit 5 1 128 19 Traktionsadresse 0 255 0 21 PoM Funktionen F1 F8 bei Traktion 0 255 0 22 PoM Funktionen F9 F15 und Licht bei Traktion 0 255 0 29 PoM Bit 0 Umpolung Fahrtrichtung Bit 1 Anzahl Fah...

Page 11: ...automatically takes on the highest order digital protocol example mfx DCC the decoder takes on the mfx Safety Notes This locomotive is only to be used with the operating system it is designed for Anal...

Page 12: ...ammed using the graphic screen on the Central Station or also partially with the Mobile Station All of the Configuration Variables CV can be read and programmed repeatedly The programming can be done...

Page 13: ...els can be set All of the functions can be controlled according to the function mapping see CV description See the CV description for the DCC protocol for additional information We recommend that in g...

Page 14: ...effect Horn Function 3 Function f3 Function f3 Rear Telex coupler Function 4 Function f4 Function f4 ABV off Function 5 Function f5 Function f5 Headlights at engineer s cab 2 off Function 6 Function...

Page 15: ...ufacturer Recognition 8 131 13 PoM Functions F1 F8 in analog operation 0 255 0 14 PoM Functions F9 F15 and lights in analog operation 0 255 1 17 Extended address upper part CV 29 Bit 5 1 192 18 Extend...

Page 16: ...e conform ment au certificat de garantie ci joint Elimination www maerklin com en imprint html L int gralit des fonctions est disponible uniquement en exploitation Trix Systems DCC et mfx Feux de sign...

Page 17: ...e roulement possible L exploitation avec courant continu de polarit inverse dans les sections de freinage n est pas possible avec le r glage d usine Si cette propri t est d sir e il faut alors renonce...

Page 18: ...ns le tableau des CVs La programmation sur la voie principale PoM doit tre support e par votre centrale voir mode d emploi de votre appareil Les param trages par d faut param trages usine peuvent tre...

Page 19: ...Fonction 3 Fonction f3 Fonction f3 Attelage Telex l arri re Fonction 4 Fonction f4 Fonction f4 ABV d sactiv Fonction 5 Fonction f5 Fonction f5 Fanal de la cabine de conduite 2 teint Fonction 6 Fonctio...

Page 20: ...t 5 1 128 19 Adresse traction 0 255 0 21 PoM Fonctions F1 F8 pour traction 0 255 0 22 PoM Fonctions F9 F15 et clairage traction 0 255 0 29 PoM Bit 0 Inv polarit Sens de marche Bit 1 Nombre de crans de...

Page 21: ...lleen mogelijk met Trix Systems DCC of met mfx bedrijf Ingebouwde rijrichtingsafhankelijke frontverlichting is in het digitaalsysteem schakelbaar Minimale te berijden radius 360 mm Rookgenerator nadie...

Page 22: ...2 0 Mfx protocol Adressering Een adres is niet nodig elke decoder heeft een nmalig en nduidig kenmerk UID De decoder meldt zich vanzelf aan bij het Central Station of Mobile Station met zijn UID Progr...

Page 23: ...e gebruiksaanwijzing van uw apparaat De default instellingen fabrieksinstelling kunnen weer hersteld worden 14 28 resp 126 rijstappen instelbaar Alle functies kunnen overeenkomstig de functiemapping g...

Page 24: ...f2 Geluid signaalhoorn Functie 3 Functie f3 Functie f3 Telex koppeling achter Functie 4 Functie f4 Functie f4 ABV uit Functie 5 Functie f5 Functie f5 Frontverlichting Cabine 2 uit Functie 6 Functie f...

Page 25: ...umsnelheid 0 255 240 8 Fabrieksinstelling fabriekherkenning 8 131 13 PoM functies F1 F8 in analoogbedrijf 0 255 0 14 PoM functies F9 F15 en licht in analoogbedrijf 0 255 1 17 Uitgebreld adres bovenste...

Page 26: ...26...

Page 27: ...27 40h...

Page 28: ...28 40h...

Page 29: ...29...

Page 30: ...30 2 3 11 3 3 3 7 5 5 20 15 16 12 21 14 4 4 9 10 8 9 19 18 17 20 13 11 15 16 6 2 1 3 5 5 3 13 Details der Darstel lung k nnen von dem Modell abweichen...

Page 31: ...r le service de r paration M rklin Opmerking enkele delen worden alleen kleurloos of in een andere kleur aangeboden Delen die niet in de in de lijst voorkomen kunnen alleen via een reparatie in het M...

Page 32: ...t legal requirements regarding electro magnetic compatibility this item may be used in the USA only after separate certification for FCC compliance and an adjustment if necessary Use in the USA withou...

Reviews: