FCC INFORMATION 

This equipment has been tested and found to comply with the limits for a class B digital 

device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a residential installation. This 

equipment generates uses and can radiate radio frequency energy and, if not installed and 

used in accordance with the instructions, may cause harmful interference to radio 

communications. 

However, there is no guarantee that interference will not occur in a particular installation. If 

this equipment does cause harmful interference to radio or television reception, which can 

be determined by turning the equipment off and on, the user is encouraged to try to correct 

the interference by one or more of the following measures: 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected. 

- Consult the dealer or an experienced radio/TV technician for help. 

Shielded interface cables and A.C. power cord, if any, must be used in order to comply 

with emission limits. 

Changes or modifications not expressly approved by the party responsible for compliance 

could void the user’s authority to operate the equipment. 

 

CE INFORMATION 

      The product must be installed according to the currently valid installation regulations for 

EMC to guarantee the designed use and to prevent EMC problems. 

      The device supplied with this manual is according to the EC, EMC Directive, 

89/336/EEC & LVD 73/23/EEC 

      Standard used for showing compliance with the essential requirements of the device: 

EN 55022 

EN 61000-3-2 

EN 61000-3-3 

EN 50130-4 

EN 55024 

LVD: EN60950-1 

 

SAFETY PRECAUTIONS 

1.  Do not modify the three-prong grounding type monitor power plug in any way. 

2.  Operate this unit only from the type of power source indicated on the label. 

3.  Do not block or cover ventilation openings on the back or bottom of the monitor 

cabinet. 

Summary of Contents for TLM-1506

Page 1: ...OPERATING INSTRUCTIONS TLM 1506 TLM 1706 TLM 1906...

Page 2: ...CE information 3 z Safety Precautions 3 1 Scope 5 2 Unpacking 5 3 Functional specification 5 4 Controls and indicators 8 5 OSD Menu 9 6 Regulatory Agency 11 7 Mechanical 11 8 Reliability 11 9 Appendix...

Page 3: ...ct the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Shielded interface cables and A C...

Page 4: ...NIT THIS ACTION MUST BE PERFORMED BY THE SERVICE TECHNICIAN AS REQUIRED DURING NORMAL MAINTENANCE 11 Refer all servicing to qualified service personnel REMOVAL OF BACK COVER BY UNAUTHORIZED PERSONNEL...

Page 5: ...Power cord US type 6 ft long black z Operating Instructions 3 Functional Specifications Power Supply The power supply spec is listed below AC INPUT AC power input range 100 240 VAC 60 50Hz 1 5Arms Ma...

Page 6: ...tion Y C S video 1 0 Vp p 0 5 1 5Vpp Automatic switching from 75 unbalanced termination to Hi Z with loop through operation VGA Input Analog RGB 0 707 Vrms VGA Timing Modes MODEL RESOLUTION TLM 1506 T...

Page 7: ...Video Two 2 BNC one in one loop thru out S Video Y C One 1 Mini DIN 4 pin one in VGA One 1 15 pin D sub Audio Two 2 RCA one in one out Environmental Temperature Operating 0o C to 40o C Storage 20o C...

Page 8: ...is button to confirm and exit the selected parameter 1 Press the buttons to adjust volume 2 Under the main OSD menu Press the buttons to move the cursor to desired selection in OSD menu 3 Press the bu...

Page 9: ...ess Press or key to adjust the value of Brightness 0 100 Contrast 0 100 Color 0 100 TINT 0 100 or Sharpness 0 3 After that hit MENU key to confirm the selected parameter and return to main menu MAIN M...

Page 10: ...irm the selected parameter and return to menu Note H Position allows user to adjust horizontal position of the image V Position allows user to adjust vertical position of the image H Size allows user...

Page 11: ...r Reset allows LCD monitor to return default setting Note User Preset allows user to adjust the color of the LCD panel 5 1 4 Language Language allows user to switch between English and Spanish COLOR T...

Page 12: ...ion V Position allows user to move OSD in vertical direction Time Out allows user to adjust the period of time that OSD shows on the screen Transparency allows user to see the image under the OSD 5 1...

Page 13: ...to recover the default setting of Mute and Volume 5 1 7 Input Select Input Select allows user to switch the VGA Video and S Video Channel 5 1 8 Reset Reset allows user to recover all default setting o...

Page 14: ...he value of Phase 0 100 Clock 0 100 H Position 0 100 or V Position 0 100 After that hit MENU key to confirm the selected parameter and return to menu MAIN MENU CONTRAST TINT SHARPNESS COLOR COLOR TEMP...

Page 15: ...o recover the default setting of Phase Clock V Position and H Position 5 3 3 Color Temperature The function is same as Video mode Please refer to 5 1 3 5 3 4 Language The function is same as Video mod...

Page 16: ...1 Weight Model TLM1 1506 TLM 1706 TLM 1906 Net weight 4 1 KG 9 0 lb 5 0 KG 11 0 lb 6 4 KG 14 5 lb Gross weight 5 8 KG 13 0 lb 6 8 KG 15 0 lb 8 6 KG 19 0 lb 7 2 Dimensions Model TLM 1506 TLM 1706 TLM 1...

Page 17: ...17 9 Appendix REAR PANEL COMPONENTS AND CONTROL VIDEO Video input Looping output S VHS S Video input AUDIO Audio input output VGA VGA input AC IN AC power input...

Page 18: ...40 V Power consumption 32W 40W Dimension Physical WxHxD mm 356x387x200mm with base 356x300x67mm without base 387x402x200mm with base 387x338x67mm without base 458x416x215mm with base 458x373x77mm with...

Page 19: ...19 TATUNG COMPANY OF AMERICA 2850 El Presidio Street Long Beach CA 90810 800 827 2850 www tatungusa com...