USER & SERVICE MANUAL

SERIES IXC- 850

W A T E R   P U R I F I C A T I O N   S Y S T E M

Summary of Contents for IXC-850 Series

Page 1: ...USER SERVICE MANUAL SERIES IXC 850 W A T E R P U R I F I C A T I O N S Y S T E M...

Page 2: ......

Page 3: ...mation displayed on screen Settings Parameter Cable connection identification Calibration of TDS sensor Control box features VII Start Up 12 Initial tests VIII Troubleshooting Guides 13 14 IX Reverse...

Page 4: ...silica and dissolved metals are equally important to determine the quality of incoming water to any water conditioning process Tritton IXC 850 RO systems have been designed and tested to provide high...

Page 5: ...lysis It is a chemical reaction of water that affects the membrane This happens when the water temperature is very high and the pH is below 2 5 or above 7 To avoid this keep the pH between 5 and 6 3 B...

Page 6: ...ded operating pressure is 180 200 PSI depending on the type of membrane The operating pressure of the system can be adjusted by regulating these combined valves Turning waste valve handle to the right...

Page 7: ...mosis system is designed to beautomaticallyoperatedbyanelectroniccontroller TheEC 100 controller monitors the operation parameters of the system and sends continuous information to the screen In addit...

Page 8: ...everse Osmosis system is switched off IV REVERSE OSMOSIS SYSTEM INSTALLATION INSTALL FOLLOWING THESE STEPS 1 Choose a place that is covered and has enough space for the system The location should also...

Page 9: ...below By default the controller provides a 10 second delay in start up of the system when you place the selector switch in AUTO for double electrical protection of the system TDS Registers the quality...

Page 10: ...frequency or time between each membrane fast flush when the system is operating P3onlyusedwhenpurchasing asystemwithfastflushintegrated IXC 850doesnothavethisoption P4 Select frequency or time betwee...

Page 11: ...s your tank Ifyouwanttoverifythecalibrationofthesensor werecommend calibration solutions in the range of 5 PPM to 10 PPM maximum Set the System selector switch to AUTO take out the sensor from its ori...

Page 12: ...S After 15 30 minutes both the feedwater and the product water must be monitored with the TDS meter You must obtain at least 95 rejection in the final product water quality If the rejection is less th...

Page 13: ...ure Waste Valve open Adjust the recommended pressure to the membrane type selected Recirculation valve completely open Check and Adjust Faulty pressure gauge Check and Replace Tubing or hose kinked or...

Page 14: ...s and waste water are reversed Change and correct reversed connections The amount of TDS in the feedwater changed An increase in its raw water TDS can alter product water quality verify the cause of t...

Page 15: ...ing it quickly Various filtering materials such as multimedia silica sand cartridge or bag filters may be used 2 Activated carbon filter The membranes central part of the Reverse Osmosis system cannot...

Page 16: ...m AQT EC 100 Controller Green Wires located on the top of the box controller ELECTRICAL INSTALLATION OPTIONS ENTRY EXIT Level Switch Green Cable Entry Level Switch Green Cable Exit Level Output Switch...

Page 17: ...aidbytheSeller orifthe Sellerisliableforthecollectionofsuchtax theamountthereofshallbeinadditiontotheamountsfortheitemsold TheBuyeragreestopayall suchtaxesortoreimbursetheSellerthereforeuponreceiptofi...

Page 18: ...Page 18 of 20 TRITTON IXC P O Box 2235 Chino Hills CA 91709 USA W A T E R P U R I F I C A T I O N S Y S T E M SERIES IXC 850 Notes...

Page 19: ......

Page 20: ...LIT IXC 850 MAN 01 07 20 2019 2020 Tritton IXC All Rights Reserved...