Forte
FaULT FINDING (continued)
problem/Symptom Cause
action/Cure
5
Shower varies
from normal
temperature to
cold during use.
6
Pressure relief
device has
operated (water
ejected from PRD
tube).
4.5
Safety cut-out
operated.
5.1
Water pressure has
dropped below
minimum required.
6.1
Blocked showerhead.
6.2
Twisted/blocked
flexible shower hose.
6.3
Showerhead not
removed while
commissioning.
4.5.1
The thermal safety cut-out device has
operated. Have the unit checked by a
suitably qualified service engineer or
contact Customer Service.
5.1.1
Wait until the water pressure returns to
normal.
6.1.1
Clean or replace blocked sprayplate in
showerhead and then fit new PRD.
6.2.1
Check for free passage through hose.
Replace the hose if necessary and fit new
PRD.
6.3.1
Fit new PRD. Commission unit with
showerhead removed.
Note:
Identify cause of operation before fitting new PRD unit.
When fitting a new PRD, follow the commissioning procedure.
It is advised all electrical maintenance/repairs to the shower
should be carried out by a suitably qualified person.
In the unlikely event of a fault occurring please contact Triton Customer Service.
Do not remove the shower from the installation.