FITTING THE SHOWER

IMPORTANT: 

Make sure that all supply 

pipework has been flushed through before 
fitting the mixer.

Screw the supplied cover trims onto the fittings 
until tight to the wall 

(fig.11).

Offer the mixer shower up to the fittings. 
Check that the sealing washers are in place.
Screw the unions onto the fittings.

Fig.11

Summary of Contents for CAROLI

Page 1: ...ISTER BY TEL 024 7637 8321 INSTALLATION AND OPERATING INSTRUCTIONS Please read this book thoroughly and familiarise yourself with all instructions before commencing installation and keep it for future...

Page 2: ...ATION 14 TEMPERATURE ADJUSTMENT RANGE 15 Recommended outlet temperatures 15 Adjusting the maximum temperature setting 15 OPERATING THE SHOWER 16 SPARE PARTS 17 18 TMV2 REQUIREMENTS 12 MONTHLY VERIFICA...

Page 3: ...Caroli Bar Mixer Shower 3 MAIN COMPONENTS Fig 1 A Thermostatic bar mixer valve B Dogleg connector X2 C Cover trim X2 B C C A...

Page 4: ...Caroli Bar Mixer Shower 4 283 50 1 2 BSP 180 00 150 00 56 25 4 0 5 0 3 4 BSP DIMENSIONS All dimensions listed in this fitting book regarding the product and installation are approximate Fig 2...

Page 5: ...at the mixer shower Water Minimum Flow Rate For best performance within the specified running pressure range a minimum flow of 8 litres per minute should be available to both inlets Water Temperature...

Page 6: ...lushed through before fitting Commercial Applications It is recommended that for all commercial applications easily accessible in line filters are used to aid maintenance Hard Water Areas a If it is i...

Page 7: ...t pressures as shown please refer to the pump installation guide to establish the minimum head requirements for automatic operation of the pump Hot water cylinder Cold supply Hot supply Alternative su...

Page 8: ...systems with no cold water take off after the appliance reducing valve it will be necessary to fit an additional drop tight pressure reducing valve when the mains pressure is over 5 bar The drop tigh...

Page 9: ...running An expansion vessel MUST be fitted and regularly maintained to ensure the unit is not damaged by excess pressures This may already be installed externally or internally within the thermal stor...

Page 10: ...ition of the shower and direction of pipe entry for example rising falling or rear entry complete the pipework to the shower area The hot and cold water pipes should be securely attached within the wa...

Page 11: ...ee of adjustment to allow for misalignment of pipe work The hot and cold supply pipes MUST be anchored rigidly to support the mixer shower and stop any movement after installation MAKING GOOD Make goo...

Page 12: ...supply pipework has been flushed through before fitting the mixer Screw the supplied cover trims onto the fittings until tight to the wall fig 11 Offer the mixer shower up to the fittings Check that...

Page 13: ...turned fully clockwise until it stops NOTE The flow control graphic styles of this may vary should be positioned so that the front edge of it is at the 12 o clock position The remainder of the graphic...

Page 14: ...ature and pressures and are within the requirements as stated on pages 2 15 Make sure the temperature control right hand side is at the maximum temperature setting WITHOUT operating the maximum temper...

Page 15: ...ratures must never exceed 46 C at terminal fitting The British Burns Association recommends 37 to 37 5 C as a comfortable bathing temperature for children In premises covered by the Care Standards Act...

Page 16: ...ntil the water stops flowing fig 17 To adjust the water temperature rotate the temperature control right hand side clockwise for a cooler water or anti clockwise for a hotter To overcome the maximum t...

Page 17: ...NBMXBKT B Bar bracket exposed UNBMXFIXEX C Bar bracket push fit UNBMXFIXBT D Straight connector 86001120 The bar mixer fittings can be purchased from Customer Spares Please check that they are suitabl...

Page 18: ...Description Part No 6 Flow regulators are available at the following ratings 12 0 L M supplied Flow regulator 3 0 L M 22010310 Flow regulator 4 0 L M 22011740 Flow regulator 5 0 L M 22011750 Flow regu...

Page 19: ...this is acceptable providing the temperature of the water seeping from the valve is no more than 2 C above the designated maximum mixed water outlet temperature setting of the valve NOTE Temperature...

Page 20: ...esults once every 12 months a Initially check the filters for debris once every three months and clean if necessary b Perform a thermal shut off test every three months and check the maximum temperatu...

Page 21: ...ter supply blocked or restricted 2 6 Flow regulator not fitted HP systems only 3 1 Flow regulators not fitted 1 1 1 Refer to commissioning section 1 2 1 Reposition temperature control knob 1 3 1 Repos...

Page 22: ...he inlet filters Clean if necessary 4 3 1 Turn off the shower and consult a suitably competent plumber 4 4 1 Clean shower head 4 5 1 Reduce the simultaneous demand 4 5 2 Make sure stop service valves...

Page 23: ...Caroli Bar Mixer Shower 23...

Page 24: ...ent of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information cont...