Triton Systems ©
15
TDN 07103-00283
Rev: B
78. Plug in the AC Power cord,
YELLOW
arrow. Place
it into the handle opening on top of the other
cables,
RED
arrow. Carefully move the dispenser
in and out of the cabinet a few times to ensure the
cables are not interfering with anything.
79. Ensure the NMD power switch (Arrow) is in the
On position.
U T
• Open the Upper cabinet and Turn the power
switch on the power supply to the ON (I) position.
• On the POST screen verify all components were
found and active.
• Log into the ATM and Navigate to
Management
Functions > Diagnostics (2) > Dispenser (4)
Test
Dispense (3)
.
• Select individual cassettes or All Cassettes for
testing. A er testing resolve any dispenser issues.
• Dispense test notes through the shutter.
• Troubleshoot as necessary or return ATM to
normal operations.
E P