![Triton Aquatronic manual power shower Installation And Operating Instructions Manual Download Page 18](http://html1.mh-extra.com/html/triton/aquatronic-manual-power-shower/aquatronic-manual-power-shower_installation-and-operating-instructions-manual_1169227018.webp)
Power shower
16
ADJUSTING THE MAXIMUM
TEMPERATURE STOP
As a safety feature the shower has a built-in
maximum temperature stop to prevent you
accidentally exceeding your highest desired
temperature. This is set in the factory to provide
a maximum temperature based on the hot
and cold water supplies being 65°C and 15°C
respectively.
IMPORTANT:
Only adjust the maximum
temperature stop when the hot water is at its
usual storage temperature.
Procedure
Rotate the temperature control to setting ‘9’ on
the temperature disc - fully hot position.
Remove the cover trim to reveal the retaining
screw
(fig.33)
.
Undo the screw and carefully pull off the
temperature control, making sure it is still
aligned to setting ‘9’. Now remove the
maximum temperature stop.
To increase the temperature stop setting,
reposition the mechanism anti-clockwise within
the arc of the grooves
(fig.34)
.
To decrease the temperature stop setting,
reposition the mechanism clockwise within the
arc of the grooves
(fig.34)
.
Replace the temperature control onto the valve
spindle. Make sure the pointer aligns with
setting ‘9’ on the temperature disc
(fig.28)
.
Secure with the retaining screw and refit the
cover trim.
Fig.33
Maximum
temperature
stop
Increase stop position
Decrease stop position
Fig.34