© Triton Electronics Ltd 2022
Doc. AMV35003_1.doc v1.04
PAGE 7 OF 52
1.2
Charging the AMV3500
The AMV3500 is charged using the 18V 3.3A DC Jack at the back of the unit. The bayonet is centre
positive. The charger will time out after approximately 4 hours, to ensure the battery is fully charged
from empty two 4 hours cycles are required.
A full charge should run the AMV3500 for 3-4 hours depending on the printer setting. When the low
battery alarm goes off there is about 15 minutes of charge left.
With regular charging cycles the battery will last for a few years.
1.3
Starting the AMV3500
To start the AMV press the ON/OFF button at the back of the unit. It takes 2 minutes to boot to the
2
Main Operating Screens and Menus
2.1
AMV3500 configuration menu
This is the main screen to setup and record a new procedure. The main sections are:
1.
Procedure information
–
this section displays the current procedure name and details. To
change the entries, press
2.
Channels to monitor, select the channels Voltage and Current these must be selected.
Temperature can be set to IP (InterPass). In this mode the temperature is taken at the start
of the weld.
2
1
3
4
5