background image

8

DEBUG Mode

DEBUG Example #1:

The cable fault is a short on Pair 3-6, the Debug 

mode LED series is as follows:
•  Pair 1-2 will flash green-green as a good pair.
•  Pair 3-6 will flash green on the PAIR LED followed 

by a red on the SHORT LED.

•  Pair 4-5 will flash green-green as a good pair.
•  Pair 7-8 will flash green-green as a good pair.

Note: 

SHIELD LED will not illuminate if the cable being 

tested is a UTP cable.

18-01-154-9337A8-EN.indd   8

1/25/2018   3:14:41 PM

Summary of Contents for T100-001-TST

Page 1: ...sur le site Web de Tripp Lite www tripplite com Tripp Lite www tripplite com PROTECT YOUR INVESTMENT Register your product for quicker service and ultimate peace of mind You could also win an ISOBAR6U...

Page 2: ...y and accurately identifies wiring faults in newly crimped or existing in wall LAN cables up to 600 ft 183 m with detachable remote unit Ergonomic design with non slip handles for secure grip Perfect...

Page 3: ...ether to score each side of the cable then pull off the jacket Stripping Round Cable Insert the cable into the slot labeled 12MM ROUN CABLE Squeeze the handles together and rotate the tool around the...

Page 4: ...s detach the remote unit from the main unit s base to allow for room to room testing Using a jumper cable not included connect the remote unit to the wall jack or patch panel to be tested Using a seco...

Page 5: ...tly Fail Indicators A flashing green LED indicates which wire pair s have a fault A solid red LED in the FAIL section will indicate which fault s are detected Multiple flashing green LEDs or solid red...

Page 6: ...opposite pin for the pair in the remote jack Split Pairs Split pairs occur when the tip positive conductor and ring negative conductor of two twisted pairs are interchanged Note The T100 001 TST will...

Page 7: ...est To DEBUG 1 Press and hold the TEST button unitl all cable pairs have been tested 2 The PAIR identification LEDs and the FAIL LEDs work together in series to identify which pair s are incorrectly w...

Page 8: ...lash green green as a good pair Pair 3 6 will flash green on the PAIR LED followed by a red on the SHORT LED Pair 4 5 will flash green green as a good pair Pair 7 8 will flash green green as a good pa...

Page 9: ...2 None No Red LED Open Condition 1 2 1 2 Reversal Pair Reversed 1 2 2 1 1 2 1 2 Short Pin 1 Shorted to Pin 2 1 2 7 8 Miswire Pin 1 Pin 7 Pin 2 Pin 8 1 2 7 8 Miswire Reversal Pin 1 Pin 8 Pin 2 Pin 7 1...