Output
Input
Output Volt Amp Capacity (VA)
Output kVA Capacity (kVA)
Output Watt Capacity (watt)
Output power factor
Nominal output voltage(s)
supported
Frequency compatibility
Output voltage regulation
(line mode)
Output voltage regulation
(battery mode)
Built-in UPS output receptacles
Built-in controllable switched
load banks
Output AC waveform (AC mode)
Output AC waveform (battery
mode)
1500
1.5
980
0.7
120V
60Hz
-18%, +8%
± 5%
6 5-15R outlet(s)
One switchable single-outlet
5-15R load bank
Sine Wave
PWM Sine Wave
Rated input current
(at maximum load)
Nominal input voltage(s)
supported
UPS input connection type
Input circuit breaker
UPS input cord length (ft)
UPS input cord length (m)
Recommended electrical
service
12A
120V AC
5-15P
15A
6
1.8
15A, 120V
Battery
Voltage Regulation
Full load runtime (minutes)
Half load runtime (minutes)
DC system voltage (VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery access
Battery replacement
description
7 minute (980W)
20 minute (490W)
36V DC
Less than 4 hours from
10% to 90%
RBC53
Battery access door
Hot-swappable, user
replaceable batteries
Voltage regulation
description
Overvoltage correction
Undervoltage correction
Severe undervoltage
correction
Automatic Voltage
Regulation (AVR) maintains
line power operation with
an input voltage range of
75 to 147
Input voltages between
128 and 147 are reduced
by 12%
Input voltages between 93
and 107 are boosted
by 14%
Input voltages between 75
and 92 are boosted by 30%
LEDs Alarms and Switches
Surge/Noise Suppression
LED indicators
Alarms
Alarm cancel operation
Switches
5 LEDs indicate line power,
battery power, overload,
voltage regulation and battery
low/replace status
Audible alarm indicates
power-failure, overload and
low-battery conditions
Power-fail alarm can be silenced
using alarm-cancel switch; once
silenced, alarm will re-sound to
indicate low-battery status
2 Switches control off/on power
status and alarm-cancel/
self-test operation
UPS AC suppression joule
rating
UPS AC suppression
response time
EMI/RFI AC noise
suppression
480J
Instantaneous
Yes
SPECIFICATIONS
• Includes 1 USB and 1 DB9 monitoring port for remote
monitoring of UPS status and site power conditions
• Communications ports enable safe unattended shutdown
without data loss during extended power failures
• Communications ports support messaging of UPS and
line power status, including on-battery, low-battery,
power-restored, AC line voltage, DC battery voltage and
battery capacity
• Communications ports support timed inverter shutoff
after unattended shutdown, activate self-test and 10
second reboot of connected equipment
• PowerAlert UPS monitoring and unattended shutdown
software with complete cabling included
• Supports Tripp Lite’s WatchDog software application to
restore unresponsive programs by automatically restarting
them and rebooting completely locked computers by
automatically switching UPS power off and back on again
• Notification of system status via 5 LEDs and multifunction
audible alarms
• Wall mountable with UPSWM wallmount bracket
• Attractive small footprint beige tower housing uses less
than 66 square inches
• Hot-swappable/user replaceable batteries allow on-site
battery replacement
• Cold start capability enables UPS turn-on in battery mode
during blackout conditions
• UL (U.S.), cUL (Canada), NOM (Mexico), Class A (Emissions)
•
$
250,000 Ultimate Lifetime Insurance (U.S. and Canada only)
• 2-year manufacturers product warranty with
$
250,000
connected equipment insurance (U.S. and Canada only)