(required for UPS operation/backup battery support; order separately)
Battery runtime can be extended with additional stand-alone hardwired external battery modules (Models BP480V26B and BP480V40C;
order separately)
Front panel combination LCD/LED display includes a real-time event log screen with up to 500 events listed
Dynamic battery management screen optimizes battery function to lengthen service life and allow cold restart of the UPS
Built-in RS-232 communication port works with included PowerAlert Software to provide shutdown commands and reporting on a single
server
Accessory slot accepts an optional internal SNMP card (Model SNMPWEBCARD) for remote shutdowns, reboots and more
Emergency Power Off button turns UPS output OFF and disables Bypass output
Built-in Emergency Power Off (EPO) dry-contact interface supports remote emergency shutdown in large facilities
Specifications
OUTPUT
Output Volt Amp
Capacity (VA)
80000
Output kVA capacity
(kVA)
80
Output Watt Capacity
(watts)
64000
Output kW capacity
64
Output power factor
0.8
Crest Factor
3:1
Nominal Output
Voltage(s) Supported
220/380V; 230/400V; 240/415V; 3-Phase Wye
Frequency
compatibility
50 / 60 Hz
Output voltage
regulation (line mode)
+/- 2%
Output voltage
regulation (Battery
mode)
+/- 2%
Built-in UPS output
receptacles
Hardwire
Output AC waveform
(AC mode)
Sine wave
Output AC waveform
(battery mode)
Pure Sine wave
INPUT
Rated input current
(at maximum load)
97A/101A/105A
Nominal Input
Voltage(s) Supported
220/380 - 230/400 - 240/415V AC 3 phase wye
UPS input connection
type
Hardwire
UPS input connection
description
220/380V, 230/400V or 240/415V , 3-phase, 4-wire + ground, wye
Phase
3-Phase
BATTERY