background image

Overvoltage
correction

Corrects overvoltages up to 300V

Undervoltage
correction

Corrects undervoltages as low as 100V

LEDS ALARMS & SWITCHES

LED Indicators

6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD
screen offers additional information and control options

Front panel LCD
display

Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options;
LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN,
ITALIAN, SPANISH and PORTUGUESE (see manual)

Alarms

Unique audible alarms for all major UPS, environmental and power conditions (see manual)

Alarm cancel
operation

Alarm cancel switch

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and
execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module
replacement

SURGE / NOISE SUPPRESSION

UPS AC
suppression
response time

Instantaneous

EMI / RFI AC noise
suppression

Yes

PHYSICAL

Installation form
factors supported
with included
accessories

Tower

Included mounting
accessory
description

2 sets of adjustable 4 post rack rails included; 2-9USTAND tower kit included (supports up to 9U in tower format)

Installation form
factors supported
with optional
accessories

2 post rackmount (2POSTRMKITHD)

Optional mounting
accessory notes

2 sets of 

2POSTRMKITHD

 required for 2 post rackmount installation of separate power module and battery pack

Primary form factor

Rackmount

UPS / Power Module
dimensions in
primary form factor
(height x width x
depth / inches)

5.14 x 17.5 x 25.82

UPS / Power Module
dimensions in
primary form factor
(height x width x
depth / cm)

13.1 x 44.4 x 65.6

Installed whole
system maximum
rack depth (inches)

32.5

Installed whole
system maximum
rack depth (cm)

82.6

Summary of Contents for SmartOnline SU8000RT3UN50

Page 1: ...Package Includes SU8000RT3UPM 3U UPS power module BP240V10RT3U external battery pack SUPDMB710 Detachable PDU with manual bypass switch Four post compatible rack rail kit 2 sets Tower stands for upri...

Page 2: ...luded rail kit supports 6U 19 inch rackmount installation in 4 post racks Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks Optional 2 9USTAND supports upright tower placement Front...

Page 3: ...ection description 3 wire single phase input L1 L2 G UPS Input cord length ft 10 UPS Input cord length m 3 Recommended Electrical Service 208 240V 50A BATTERY Full load runtime minutes 5 5 min 7200w H...

Page 4: ...s support set and execute scrolling LCD functions bundled PDU includes bypass switch to enable hot swap UPS power module replacement SURGE NOISE SUPPRESSION UPS AC suppression response time Instantane...

Page 5: ...width x depth inches 39 8 x 31 5 x 23 UPS Shipping dimensions height x width x depth cm 101 x 80 x 58 4 Shipping weight lbs 331 Shipping weight kg 150 3 UPS housing material Steel Cooling method Fan...

Page 6: ...FEATURES Cold Start startup in battery mode during a power failure Cold start operation supported Economy mode operation Optional economy mode enables high efficiency bypass operation with a maximum...

Page 7: ...Metered 0U Vertical Rack PDU Metered Power Distribution Unit for Network Applications 1 Power Distribution PDUMV20HVNET Switched Metered PDU with Remote Monitoring 0U Vertical Rackmount Power Distribu...