background image

Input Phase

Single-Phase

OUTPUT

Output Volt Amp Capacity (VA)

750

Output Capacity (kVA)

.75

Output Watt Capacity (Watts)

675

Output Capacity Details

ON LINE MODE: Maximum output capacity is reduced to 608 watts at 100V nominal; FREQUENCY CONVERSION
MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120/115/110V: 472
watts / 100V: 425 watts)

OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150%
load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and
frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE
bypass limits)

Power Factor

0.9

Crest Factor

3:1

Nominal Voltage Details

120V factory-default nominal voltage

Frequency Compatibility

50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion

Frequency Compatibility Details

ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output
matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz  when input frequency exceeds
+/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz.
FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency
input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz.  BATTERY
MODE: Output is regulated to +/-0.05Hz.

Output Voltage Regulation (Line
Mode)

+/- 2%

Output Voltage Regulation
(Economy Line Mode)

+/- 10%

Output Voltage Regulation (Battery
Mode)

+/- 3%

Load Management Receptacles

Two switchable single-outlet 5-15R load banks

Output AC Waveform (AC Mode)

Pure Sine wave

Output AC Waveform (Battery
Mode)

Pure Sine wave

Nominal Output Voltage(s)
Supported

100V; 110V; 115V; 120V; 127V

Output Receptacles

(6) 5-15R

Individually Controllable Load Banks

Yes

BATTERY

Battery Type

Valve Regulated Lead Acid (VRLA)

Full Load Runtime (min.)

4.3 min. (675w)

Half Load Runtime (min.)

13.9 min. (337.5w)

Expandable Battery Runtime

Extended runtime supported via optional external battery packs

Expandable Runtime

Yes

3 / 7

Summary of Contents for SmartOnline SU750RTXLCD2U

Page 1: ...port offers both enhanced RS 232 data and basic contact closure monitoring ability HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows...

Page 2: ...bles tower placement Single line TEL Network surge suppression Electronic bypass maintains utility output during a variety of UPS fault conditions Battery independent restart ensures automatic UPS pow...

Page 3: ...d to match nominal input frequency on startup Output matches input frequency when 5Hz of nominal Output is regulated to 0 05Hz when input frequency exceeds 5Hz of nominal UPS switches to battery mode...

Page 4: ...tage Regulation Description Online double conversion power conditioning maintains 2 output voltage regulation during brownouts and overvoltages Overvoltage Correction Corrects overvoltages to 150V 0 1...

Page 5: ...pplite com 2U 9U Tower Stand Kit select Rack Mount UPS Systems 2 9USTAND 2 9USTAND a nbsp enables upright tower UPS placement nbsp a class productLink href www tripplite com 2 Post Rack Mount Wall Mou...

Page 6: ...ling included WatchDog Compatibility Supports Watchdog application OS and hard reboot restart options for remote applications Network Management Card Description Network management card optional Commu...

Page 7: ...subject to change without notice Tripp Lite uses primary and third party agencies to test its products for compliance with standards See a list of Tripp Lite s testing agencies https www tripplite co...

Reviews: