background image

UPS input connection type

Hardwire

UPS input connection description

3 wire single phase input (L1, L2, G)

Recommended Electrical Service

100A @ 200V-240V (L, N, PE), or 100A @ 200V, 208V, or 240V (L1, L2, G)

Phase

Single-Phase

BATTERY

Full load runtime (minutes)

5.5 minutes (14,400 watts)

Half load runtime (minutes)

13.5 minutes (7200 watts)

Expandable battery runtime

Runtime is expandable with external battery packs

External battery pack compatibility

BP240V10RT3U

BP240V557C-1PH

BP240V787C-1PH

BP240V1037C-1PH

BP240V1407C-1PH

Expandable runtime description

For best results, add external batteries in multiples of two so that both included 8kVA power modules have an equal
number and type of connected battery packs

DC system voltage (VDC)

240

Battery recharge rate (included
batteries)

Less than 8 hours from 10% to 90%

Battery replacement description

Hot-swappable, user replaceable external battery packs

VOLTAGE REGULATION

Voltage regulation description

2% output voltage regulation in standard online, double-conversion mode

Overvoltage correction

Corrects overvoltages up to 300V

Undervoltage correction

Corrects undervoltages as low as 100V

LEDS ALARMS & SWITCHES

LED Indicators

6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD
screen offers additional information and control options

Front panel LCD display

Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options;
LED/LCD panel rotates for viewing in rack/tower formats (see manual)

Alarms

Unique audible alarms for all major UPS, environmental and power conditions (see manual)

Alarm cancel operation

Alarm cancel switch

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and
execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module
replacement

SURGE / NOISE SUPPRESSION

UPS AC suppression response time

Instantaneous

EMI / RFI AC noise suppression

Yes

PHYSICAL

Included mounting accessory
description

4 sets of adjustable 4 post rack rails included (one for each included 3U module)

3 / 6 

 

Summary of Contents for SmartOnline SU16KRTHW

Page 1: ...th manual bypass switch enables hot swap replacement power modules at any supported load level Hardwire input and output connections Maintains full time sine wave output within 2 of selectable 200 208 220 230 240V nominal Supports 50 60Hz operation for worldwide frequency compatibility Expandable runtime with optional external battery packs Some external battery configurations require the use of T...

Page 2: ...ously in double conversion mode 106 to 125 for 1 minute 126 to 150 for 30 seconds Loads over 150 trigger immediate bypass mode operation to support loads directly from mains power Double conversion mode is automatically restored as load levels are reduced to 95 or less Nominal Output Voltage s Supported 200V 208V 220V 230V 240V Nominal Voltage details Voltage selection via front panel LCD interfac...

Page 3: ...tandard online double conversion mode Overvoltage correction Corrects overvoltages up to 300V Undervoltage correction Corrects undervoltages as low as 100V LEDS ALARMS SWITCHES LED Indicators 6 LEDs indicate line power online mode economy bypass mode on battery charger and AC output status LCD screen offers additional information and control options Front panel LCD display Selectable LCD display w...

Page 4: ...UPM UPS Power modules and 2 BP240V10RT3U Battery packs Listed weights and dimensions for UPS Power module and Included battery pack each refer to a single unit Included battery pack dimensions height x width x depth inches 5 25 x 17 5 x 25 Included battery pack dimensions height x width x depth cm 13 3 x 44 5 x 63 5 Included battery pack weight lbs 158 7 Included battery pack weight kg 72 UPS Ship...

Page 5: ...e 0 ms in online double conversion mode Transfer time economy mode 8 milliseconds typical power failure response in optional economy mode Low voltage transfer to battery power setpoint 100V High voltage transfer to battery power setpoint 300V SPECIAL FEATURES Cold Start startup in battery mode during a power failure Cold start operation supported Economy mode operation Optional economy mode enable...

Page 6: ...External Battery Pack and Cable 3U Expandable Black 3 Point Connector 1 BP240V557C 1PH External battery pack for use with select Tripp Lite UPS Systems 1 BP240V787C 1PH External battery pack for use with select Tripp Lite UPS Systems 1 BP240V1037C 1PH External battery pack for use with select Tripp Lite UPS Systems 1 BP240V1407C 1PH External battery pack for use with select Tripp Lite UPS Systems ...