Tripp Lite PowerVerter RV1012UL Owner'S Manual Download Page 7

7R

Set Battery Charging Amps—OPTIONAL

(function included

on       switch on 612 models)

Check specifications for your unit’s high- and
low-charging amp options. By setting on
high charging, your batteries will charge at
maximum speed and your RV 12V DC
system loads will be well-supplied. When
setting on low charging, you lengthen the life of your batteries
(especially smaller ones).

Battery Charger

Switch Position

Low Charge Amps

Up 

High Charge Amps

Down (factory setting)

CAUTION: When switching to the High Charge Amp setting, the user must ensure that the amp
hour capacity of their battery system exceeds the amperage of the High Charge Amp setting or
the batteries may be damaged or degraded.

Select Equalize Battery Charge—OPTIONAL

(Not on 612 Models)

This DIP Switch is momentarily engaged
to begin the process of equalizing the
charge state of your battery’s cells by time-
limited overcharge of all cells. This can
extend the useful life of certain types of batteries; consult with your
battery’s manufacturer to determine if your batteries could benefit
from this process. The charge equalization process is automatic;
once started, it can only be stopped by removing the input power.

Setting Procedure

• Move to “Equalize” (DOWN) position for three seconds.
• Move to “Reset” (UP) position and leave it there. This is the 

factory default setting.

CAUTION: Do not leave DIP switch #B3 in the down position after beginning process. Battery
charge equalization should only be performed in strict accordance with the battery manufacturer’s
instructions and specifications.

Battery Charge

Switch Position

Reset

Up (factory setting)

Equalize

Down—momentarily

Select Battery Charger-Limiting Points—OPTIONAL

(Not on 612 Models)

Most Limiting (#B1 & #B2 Up, factory setting):
Charger-limiting takes effect the moment
any 120V AC load is applied; charger output
falls gradually from full output at no 120V
load passing through to no output at full load.

Less Limiting (#B1 Down & #B2 Up):
Charger-limiting begins when the
Inverter/Charger’s load reaches 33% of the
Inverter/Charger’s load rating. Charger
output falls gradually from full output at 33% of the
Inverter/Charger’s load rating to about 40% of full output at full load.

Least Limiting (#B1 Up & #B2 Down):
Charger-limiting begins when the
Inverter/Charger’s load reaches 66% of the
Inverter/Charger’s load rating. Charger
output falls gradually from full output at
66% of the Inverter/Charger’s load rating to about 40% of full output
at full load.

No Limiting (#B1 & #B2 Down): No
charger-limiting occurs at any load size.

Configuration 

(continued)

B1

B2

B3

B4

B1

B2

B3

B4

B1

B2

B3

B4

B1

B2

B3

B4

B1

B2

B3

B4

Set Battery Charge Conserver (Load Sense) Dial—OPTIONAL

(Not on 612 models)

In order to save battery power, the unit’s inverter automatically shuts off in the absence of any power demand from connected
equipment or appliances (the electrical load). When the unit detects a load, it automatically turns its inverter function on.
Users may choose the minimum load the Inverter/Charger will detect by adjusting the Battery Charge Conserver Dial (see
diagram). Using a small tool, turn the dial clockwise to lower the minimum load that will be detected, causing the inverter to
turn on for smaller loads. When the dial is turned fully clockwise, the inverter will operate even when there is no load. Turn the dial counter-
clockwise to increase the minimum load that will be detected, causing the inverter to stay off until the new minimum load is reached. 

Note: the factory setting for the dial is fully clockwise. However, based on the threshold load to which you’d like the inverter to respond, you should adjust the dial counterclockwise to reduce its sensi-
tivity until the inverter is active only when connected equipment or appliances are actually in use.

Connect Remote Control—OPTIONAL

(All models)

All models feature an 8-conductor telephone style receptacle on the front panel for use with an optional remote control module (Tripp Lite model
APSRM2, sold separately or included with select models). The remote module allows the Inverter/Charger to be mounted in a compartment or cabinet out
of sight, while operated conveniently from within the living area or control panel of your RV. See instructions packed with the remote control module.

Connect Battery Temperature Sensing Cable—OPTIONAL

(not on 612 models)

The battery temperature sensing function prolongs battery life by adjusting the charge float voltage level based on battery temperature. Connect
the sensor cable (the cable, included with select models, has an RJ style connector on one end and a black sensor on the other) to the RJ
style jack located on the side of the Inverter/Charger labeled “Remote Temp. Sense.” Affix the sensor to the side of your battery below the
electrolyte level. To guard against false readings due to ambient temperature, place the sensor between batteries, if possible, or away from
sources of extreme heat or cold. If the sensor cable is not used, the Inverter/Charger will charge according to its default 25º C values.

Utilize Automatic Generator Starter Capability—OPTIONAL

(not on 612 models))

All models except 612 models include an RJ type modular jack on the side panel labeled “Generator Start”. Attach to vehicle
generator ON/OFF switching mechanism with user-supplied cable (see Pin Configuration Diagram). Once
attached, the interface will allow the Inverter/Charger to automatically switch a vehicle generator on when connected bat-
tery voltage levels are low (11.6 VDC) and switch it off when battery voltage levels are high (14.1 VDC).

Reset

Equalize

B1

B2

B3

B4

B4

B3

A4

1

2

3

4

5

6

Pin Configuration

2 - Common

3 - N.C.  
 (Normally 

Closed)

4 - N.O.  
 (Normally 

Open) 

Summary of Contents for PowerVerter RV1012UL

Page 1: ...remium Protection Levels Built In ISOBAR Surge Protection Automatic Overload Protection Ideal Output for All Loads including computers Frequency Controlled Output Fast Load Switching Balanced Load Sharing Better for Your Batteries Faster Battery Recharge High Amp 3 Stage Battery Charger adjustable Critical Battery Protection Battery Charge Conserver Load Sense Battery Temperature Sensing High Effi...

Page 2: ...Hardwire Hardwire Hardwire Hardwire Hardwire Hardwire Hardwire INVERTER Common Specifications for All Models DC Input Volts Nominal 12 VDC DC Input Voltage Range 10 15 VDC Output Volts Nominal 120 VAC 5 Output Frequency Nominal 60 Hz 0 5 Efficiency 88 to 94 depending on load and temperature Select Tripp Lite Inverter Chargers include a Battery Charge Conserver Load Sense Control which saves batter...

Page 3: ... be installed whether for a mobile or stationary application in a dead air compartment Ideally any compartment would have some ventilation to outside air Sparks may result during final battery connection Always observe proper polarity as batteries are connected Do not allow objects to contact the two DC input terminals Do not short or bridge these terminals together Serious personal injury or prop...

Page 4: ...I receptacle output See page 11 for connection instructions Resettable Circuit Breaker protect your Inverter Charger against damage due to overload See page 5 for resetting instructions Remote Control Module Connector allows remote monitoring and control with an optional module Tripp Lite model APSRM2 sold separately or included with select models See remote module owner s manual for connection in...

Page 5: ...erator source If the operating mode switch is set to CHARGE ONLY this light will BLINK to alert you that the unit s inverter is OFF and will NOT supply AC power in the absence of a utility generator source or in over under voltage situations INV Inverting Yellow Indicator This light will ILLUMINATE CONTINUOUSLY whenever connected equipment is receiving battery supplied inverted AC power in the abs...

Page 6: ...o momentary high low line voltage swings that would have little effect on equipment operation you may wish to adjust these settings By increasing the High AC Voltage Point and or decreasing the Low AC Voltage Point you will reduce the number of times your unit switches to battery due to voltage swings Group B DIP Switches Not on 612 Models Select Load Sharing OPTIONAL Not on 612 Models Your Invert...

Page 7: ...t s inverter automatically shuts off in the absence of any power demand from connected equipment or appliances the electrical load When the unit detects a load it automatically turns its inverter function on Users may choose the minimum load the Inverter Charger will detect by adjusting the Battery Charge Conserver Dial see diagram Using a small tool turn the dial clockwise to lower the minimum lo...

Page 8: ...ve by the battery voltage 12 to determine the DC amps required STEP 3 Estimate Battery Amp Hours Required for operation unsupported by the alternator Multiply the DC amps required from step 2 above by the number of hours you estimate you will operate your equipment exclusively from battery power before you have to recharge your batteries with utility or generator supplied AC power Compensate for i...

Page 9: ...rter Charger cabinet Install and tighten two user supplied 6 mm fasteners into the mounting feet molded on the rear of the Inverter Charger cabinet The rear feet extend beyond the unit s cabinet to provide for adequate ventilation space behind the cooling fan s they should not be removed 6 4 727 32 6 11 4 cm 17 1 cm 20 cm 17 1 cm C B M A C B M A B A B C 10 26 4 cm 3 Note RV model cabinets may have...

Page 10: ...rical system In most vehicles the Inverter Charger will be connected to one or more dedicated auxiliary house batteries which are isolated from the drive system to prevent possible draining of the main battery 12 Volt Inverter Charger 12 Volts 12 Volts 3 5 12 Volt Main Battery Connection 12 Volt Alternator Vehicle Battery Ground 12 Volt Main Battery 12 Volt Auxiliary House Battery UL Listed Fuse F...

Page 11: ...e on each 120V leg or two different 120V sources The Inverter Charger will only supply 120V output power and WILL NOT provide 240V output even if it is connected to inputs from a split 240V service when in inverter mode When the Inverter Charger is receiving AC power it can supply connected loads with up to 20 amps of power on each circuit When the Inverter Charger is not receiving AC power and ha...

Page 12: ...oving Operating Mode Switch to OFF Wait 1 minute Switch to AUTO REMOTE or CHARGE ONLY Battery Not Recharging Connected batteries are dead Check and replace old batteries AC Input Present Battery fuse is blown Check and replace fuse Battery cabling is loose Check and tighten or replace cabling Unit has shut down due to battery overcharge preventing Disconnect any auxiliary chargers Reset by moving ...

Reviews: