Battery Selection

54 DC Amps × 5 Hrs. Runtime

270 Amp-Hours

Match Battery Amp-Hour Capacity to Your Application

Select a battery or system of batteries that will provide your Inverter with proper DC voltage and an adequate amp-hour capacity to power
your application. Even though Tripp Lite Inverters are highly efficient at DC-to-AC inversion, their rated output capacities are limited by the
total amp-hour capacity of connected batteries plus the output of an alternator when one is used.

• STEP 1) Determine Total Wattage Required

Add the wattage ratings of all equipment you will connect to your
Inverter. Wattage ratings are usually listed in equipment manuals or on
nameplates. If your equipment is rated in amps, multiply that number times
AC utility voltage to estimate watts. (Example: a drill requires 1.3 amps.
1.3 amps × 230 volts = 300 watts.) 

NOTE: Your Inverter will operate at higher efficiencies at about 75% - 80% of nameplate rating.

• STEP 2) Determine DC Battery Amps Required

Divide the total wattage required (from Step 1, above) by the battery voltage
to determine the DC amps required and multiply by 1.2 to account for
conversion losses.

• STEP 3) Estimate Battery Amp-Hours Required

Multiply the DC amps required (from Step 2, above) by the number of hours
you estimate you will operate your equipment exclusively from battery
power before you have to recharge your batteries. This will give you a
rough estimate of how many amp-hours of battery power (from one or
several batteries) you should connect to your Inverter.

NOTE: Battery amp-hour ratings are usually given for a 20-hour discharge rate. Actual amp-hour capacities
are less when batteries are discharged at faster rates. For example, batteries discharged in 55 minutes
provide only 50% of their listed amp-hour ratings, while batteries discharged in 9 minutes provide as little
as 30% of their amp-hour ratings.

Example

Tools

300W +  220W +  20W 

540W

Drill

Orbital Sander

Cordless Tool Charger

Appliances

300W +  140W +  100W 

540W

Blender

Color TV

Laptop Computer

Mounting

WARNING! Mount your Inverter BEFORE DC battery connection. Failure to follow
these instructions may lead to personal injury and/or damage to the Inverter and
connected systems.

1

2

3

Tripp Lite recommends that you permanently mount your Inverter
in the configuration illustrated below. The Inverter features integral
mounting brackets on the front and rear of the unit. The user must
supply mounting hardware and is responsible for determining if
hardware and mounting surface are adequate to support the weight
of the unit.
Using the measurements as shown in the diagram install two user-
supplied fasteners 

, leaving the heads slightly raised. Slide the

unit over the fasteners to engage the mounting bracket slots 

.

Tighten fasteners. Install two additional fasteners 

over the

remaining mounting bracket. 

3

2

1

1.2 x 540 watts ÷ 12V = 

54 DC Amps

Summary of Contents for PowerVerter PVX700

Page 1: ...always have battery power to start your vehicle PowerVerter DC to AC Inverter Model PVX700 Input Output 12V DC 230V 50Hz AC 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1212 www tr...

Page 2: ...atteries of identical voltage age amp hour capacity and type Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated your batteries should not be installed wh...

Page 3: ...nditions and shuts down the Inverter as a protective measure Turn the ON OFF switch to the OFF position if the alarm sounds See the Operation section for more information 1 2 3 4 5 4 3 5 1 2 Operation...

Page 4: ...power before you have to recharge your batteries This will give you a rough estimate of how many amp hours of battery power from one or several batteries you should connect to your Inverter NOTE Batt...

Page 5: ...able Sizing Connect Ground Using a 12 18 AWG 1 2 mm wire directly connect the Main Ground Screw to the vehicle s chassis or earth ground See the Feature Identification section to locate the Main Groun...

Page 6: ...e product has been assigned a unique series number The series number can be found on the product nameplate label along with all required approval markings and information When requesting compliance in...

Page 7: ...n de energ a CA Los inversores PowerVerter incluyen caracter sticas avanzadas que protegen su equipo alargando la vida de servicio de su bater a y que aseguran que siempre contar con suficiente energ...

Page 8: ...as hidr geno explosivo cerca de las bater as si no est n bien ventiladas no debe instalar bater as ya sea para una aplicaci n m vil o estacionaria en un compartimiento sin circulaci n de aire En forma...

Page 9: ...a y apaga el Inversor como una medida de protecci n Coloque el interruptor ON OFF Encendido Apagado en la posici n OFF Apagado si sonara la alarma Vea la secci n Operaci n para m s informaci n 1 2 3 4...

Page 10: ...er a antes de tener que recargar sus bater as Esto le dar un estimado grueso de cuantos amperios hora de energ a de bater a de una o varias bater as debe conectar a su inversor NOTA La capacidad de am...

Page 11: ...e 45 cm 18 de la bater a La capacidad del fusible debe ser igual o mayor que la M nima capacidad de fusible de CC indicada en las especificaciones de su inversor Vea la secci n Especificaciones para r...

Page 12: ...Completa 1 2 horas 2 4 horas continuos Motor Encendido En Marcha 1 2 Carga Motor Apagado no recomendado 1 hora 2 horas Carga Completa no recomendado no recomendado 1 hora Motor Apagado NOTA Puede max...

Page 13: ...NEIDAD PARA UN PROP SITO PARTICULAR Algunos estados no permiten limitaciones o exclusiones de las garant as impl citas por lo tanto las limitaciones o exclusiones mencionadas anteriormente pueden no a...

Page 14: ...manquent de courant CA Les convertisseurs PowerVerter comprennent des caract ristiques perfectionn es qui prot gent votre quipement prolongent la dur e de service de votre batterie et garantissent que...

Page 15: ...nstaller vos batteries que ce soit pour une application mobile ou stationaire dans un compartiment sans circulation d air Id alement tout compartiment devrait disposer d une ventilation d air ext rieu...

Page 16: ...tiquement des conditions de surcharge et arr te le convertisseur par mesure de protection Mettre l interrupteur ON OFF en position OFF si l alarme retentit Voir la section Fonctionnement pour plus de...

Page 17: ...nt que vous ne deviez recharger vos batteries Cela vous donnera une estimation grossi re de la puissance de batterie enA h d une ou de plusieurs batteries que vous devrez brancher votre onduleur REMAR...

Page 18: ...la batterie Le calibre nominal du fusible doit tre gal ou sup rieur au calibre minimal de fusible CC inscrit dans les sp cifications Voir les sp cifications pour les recommandations de fusible et de b...

Page 19: ...eure moteur l arr t NOTE Vous pouvez maximiser la puissance de sortie en suivant une ou plus de ces tapes 1 connecter plusieurs batteries au convertisseur 2 garder les batteries pleine charge en faisa...

Page 20: ...ADAPTATION UNE APPLICATION PARTICULI RE Certaines provinces ou tats ne reconnaissent ni l exclusion ni la limite des garanties implicites les limites ou les exclusions susmentionn es peuvent ne pas co...

Page 21: ...treet Chicago IL 60609 USA 773 869 1212 www tripplite com 2007 PowerVerter Tripp Lite PowerVerter P PV VX X7 70 00 0 12 230 50 Espa ol Fran ais English 22 27 23 23 24 24 25 26 7 14 1 26 PowerVerter 12...

Page 22: ...Tripp Lite he 5 Tripp Lite Tripp Lite UPS Uninterruptible Power Supply 22...

Page 23: ...23 20 ON OFF ON OFF OFF ON OFF OFF ON OFF OFF 1 2 3 4 5 4 3 5 1 2 ON OFF ON ON OFF OFF OFF 1 ON OFF OFF 2 3 4 5 ON OFF ON 1 ON OFF OFF 2 3 4 5 ON OFF ON...

Page 24: ...24 Tripp Lite 1 1 3 1 3 230 300 75 80 2 1 1 2 3 2 20 55 50 9 30 300 220 20 540 300 140 100 540 1 2 x 540 12 54 54 5 270 Tripp Lite 3 2 1 1 2 3...

Page 25: ...25 5 mm 4 AWG American Wire Gauge 200 3 5 1 2 mm 12 18 AWG American Wire Gauge Tripp Lite 45 18 12 12 12 1 2 3 5 7 8 8 7 4 5 3 2 2 6 1 12 12 12 CE 45 4 5 12 18 1 2 8 7 6 5 4 3 2 1...

Page 26: ...26 Tripp Lite Tripp Lite Tripp Lite RMA Returned Material Authorization 10 5 ON 10 PVX700 700 1400 12 10 15 230 50 PWM 10 5 10 1 125 6 4 4 5 12 18 1 2...

Page 27: ...27 4 4 6 6 8 8 PVX700 1 2 1 2 2 4 1 2 1 2 1 1 2 3 4 5 6 6 4 4 5 Tripp Lite 1 Tripp Lite RMA Tripp Lite Tripp Lite Tripp Lite Tripp Lite 10 TRIPP LITE TRIPP LITE Tripp Lite Tripp Lite Tripp Lite...

Page 28: ...28 200701124 93 2655 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1212 www tripplite com...