20 millisecond automatic transfer between line and battery power supports UPS protection during blackouts and voltage fluctuations for
equipment compatible with a one cycle transfer time
Double Boost inverter output supports momentary startup loads up to 200% of the continuous rating for up to 10 seconds (see specification
chart)
OverPower inverter output supports longer duration overloads to 150% for 1-60 minutes under ideal battery and temperature conditions.
3 stage, 30 amp battery charger with adjustable settings for wet/gel battery types offers fast, reliable battery recharging
3 position operating mode switch supports "AUTO" mode to enable automatic transfer between DC and AC modes, CHARGE-ONLY to
maintain a full battery charge when AC is present without auto transfer and SYSTEM OFF settings
Set of six front panel LEDs display AC/DC operational modes, overload status, DC voltage level, shutdown status and system fault status
Set of 4 configuration dipswitches support wet/gel battery charging profiles, adjustable 259/264V high voltage auto transfer during
overvoltages and selectable 144/163/182/201V AC low voltage auto transfer during brownouts
Set of 4 additional configuration dip switches support 4 levels of charger limiting relative to output load size
Resettable 10A charger AC input breaker and resettable 15A AC output breaker and automatic 2 speed cooling fan protect the inverter from
load and temperature related failures
Automatic overload and thermal shutoff safely turns off inverter as excessive loads or overheating conditions develop
Front panel remote control connector enables remote off/on switching (requires APSRM4 switch accessory)
Specifications
OVERVIEW
Intended
Application
Emergency Home Power
OUTPUT
Frequency
compatibility
50 Hz
Output watts
3600
Continuous output
capacity (watts)
3600
Peak output
capacity (watts)
7200
Output nominal
voltage
230V
Output voltage
regulation
LINE POWER (AC): Maintains 230V nominal sine wave output from line power source. INVERTER POWER (AC):
Maintains PWM sine wave output voltage of 230 VAC (+/-5%).
Output frequency
regulation
50 Hz (+/- 0.3 Hz)
Overload
protection
Includes 12A input breaker dedicated to the charging system and 20A output breaker for AC output loads.
Outlet quantity /
type
Hardwire
INPUT
Recommended
Electrical Service
DC INPUT: Requires 36VDC input source capable of delivering 114A for the required duration (when used at full
continuous capacity - DC requirements increase during OverPower and DoubleBoost operation). For automotive
applications, professional hardwire installation with 300A minimum battery system fusing is recommended.
Maximum input
amps / watts
DC INPUT: Full continuous load - 114A at 36VDC. AC INPUT: 26 amps at 230VAC with full inverter and charger load
(10.4A max charger-only / combined input load to support charger and AC output is automatically controllable to
66%-33%-0% based on AC output loading using the charger limiting set points - see manual for setting instructions)
Input connection
type
DC INPUT: Set of DC bolt-down terminals. AC INPUT: Hardwire via built in junction box with cover plate
Voltage
compatibility (VAC)
230