background image

750 watts continuous AC output in inverter mode, 1500 watts continuous AC output in AC mode

Double Boost™ inverter output supports momentary start-up loads up to 200% of the continuous rating for up to 10 seconds

OverPower™ inverter output supports longer duration overloads to 150% for 1-60 minutes under ideal battery and temperature conditions.

(For best results, utilize OverPower usage for as short of a duration as possible, ensure battery bank and cabling is able to provide full

nominal DC voltage under load and allow inverter/charger to fully cool before and after OverPower usage.)

3 stage, 20 amp battery charger with adjustable settings for wet/gel battery types offers fast, reliable battery recharging

Protected hardwire bolt-down input lugs safely accept heavy gauge input wiring from attached battery bank

Two built-in NEMA 5-15R output receptacles pass 120V line power or inverter output through to connected equipment

Reliability enhanced large-transformer design with secure mounting flanges and protected DC wiring terminals

Moisture-resistant construction enables vehicular or marine operation in high humidity environments

3 position operating mode switch supports "AUTO" mode to enable automatic transfer between DC and AC modes, CHARGE-ONLY to

maintain a full battery charge when AC is present without auto transfer and SYSTEM OFF settings.

Set of six front panel LEDs display AC/DC operational modes, overload status, DC voltage level, shutdown status and system fault status

Set of 4 configuration dip-switches support wet/gel battery charging profiles, adjustable 135/145V high voltage auto transfer during

overvoltages and selectable 75/85/95/105V AC low voltage auto transfer during brownouts

Resettable 6A charger AC input breaker and resettable 8A AC output breaker and automatic 2 speed cooling fan protect the inverter from

load and temperature related failures

Grounding lug properly connects the inverter/charger system to earth ground or vehicle grounding system

Automatic overload and thermal shutoff safely turns off inverter as excessive loads or overheating conditions develop

Front panel remote control connector enables remote off/on switching (requires APSRM4 switch accessory). Optional APSRM4 accessory

also includes user configurable jacks to support inverter shutoff or start-up as a vehicle ignition is engaged.

Specifications

OVERVIEW

Intended Application

Emergency Home Power

OUTPUT

Frequency
compatibility

60 Hz

Output watts

750

Continuous output
capacity (watts)

750

Peak output capacity
(watts)

1500

Output nominal
voltage

120V

Output voltage
regulation

LINE POWER (AC): Maintains 120V nominal sine wave output from line power source. INVERTER POWER (AC):
Maintains PWM sine wave output voltage of 120 V AC (+/-5%).

Output frequency
regulation

60 Hz (+/- 0.3 Hz)

Overload protection

Includes 6A AC input breaker dedicated to the charging system and 8A output breaker for AC output loads

Outlet quantity / type

2 NEMA 5-15R

INPUT

Nominal Input
Voltage(s) Supported

120V AC

Recommended
Electrical Service

DC INPUT: Requires 12V DC input source capable of delivering 72A for the required duration (when used at full
continuous capacity - DC requirements increase during Over-Power and Double-Boost operation). AC INPUT: 15A
120V AC recommended

Maximum input
amps / watts

DC INPUT: Full continuous load - 72A at 12V DC. AC INPUT: 8 amps at 120VAC with full inverter and charger load
(4.2A max charger-only)

Input connection type

DC INPUT: Set of 2 DC bolt-down terminals. AC INPUT: NEMA 5-15P input plug