Your UPS may be rackmounted in 4- or 2-post racks or on a DIN rail using these suggested mounting
procedures. The procedures are for common rack/rail types and may not be appropriate for all con-
figurations. User must determine the fitness of hardware and procedures before mounting.

1

1

2

Attach mounting ears (A) to the front mounting
holes of the UPS (B) using the screws pro-
vided (C). 

Have an assistant lift the UPS and hold it in
position with the mounting ears flush against
the rack’s side supports. Mount the UPS by
screwing user-supplied rack hardware (D)
through its mounting ears, and into the rack’s
side supports. 

2

Suggested Rackmount Installation

Mounting

Suggested DIN Rail Installation

1

1

2

Attach the DIN mounting brackets (A) to the
mounting ears by lining the brackets’ captive
nuts up with the mounting ears’ holes, then
attaching them with the bolts provided (B).
Attach mounting ears (C) to the rear mounting
holes of the UPS using the screws provided
(D). Note that there is a left mounting bracket
and a right mounting bracket; the deeper slot
of each should be on top.

Hang the UPS on the DIN rail by inserting
the DIN rail’s top into the top (deeper) slots
of the DIN mounting brackets, then ease the
UPS into a horizontal position so that the
DIN rail’s bottom fits into the mounting
brackets’ bottoms. Fasten the UPS into 
postion with the screws provided (E).

2

A

B

D

A

D

C

B

E

C

200307055 93-2171 OM500RMX Owner’s Manual Revision.qxd  7/11/2003  10:14 AM  Page 3

Summary of Contents for OmniSmart RMX 500 VA OM500RMX

Page 1: ...com Important Safety Instructions 2 Mounting 3 Connection 4 Basic Operation 5 Storage and Service 8 Copyright 2003 Tripp Lite All rights reserved OmniSmart is a trademark of Tripp Lite OmniSmart RMX 5...

Page 2: ...are no user serviceable parts inside Because the batteries present a risk of electrical shock and burn from high short circuit current observe proper precautions Unplug and turn off the UPS before per...

Page 3: ...o the rack s side supports 2 Suggested Rackmount Installation Mounting Suggested DIN Rail Installation 1 1 2 Attach the DIN mounting brackets A to the mounting ears by lining the brackets captive nuts...

Page 4: ...reen yellow terminal Connect the incoming hot wire to the HOT IN brown terminal Connect the incoming neutral wire to the NEUTRAL IN blue terminal Connect the outgoing hot wire to the HOT OUT black ter...

Page 5: ...ode will put the UPS in the ON mode Cutting AC power to the UPS while it is in STANDBY mode will put the UPS in the OFF mode ON The light is on The UPS is receiving AC power charging its batteries and...

Page 6: ...batteries may need replacing or the batteries may simply be less than fully charged Let the UPS charge for twelve hours then perform a second self test If the LOW BATTERY alarm sounds again contact Tr...

Page 7: ...Lite offers a complete line of UPS System Replacement Battery Cartridges R B C Visit Tripp Lite on the Web at www tripplite com support battery index cfm to locate the specific replacement battery for...

Page 8: ...ge 120V Input Frequency 60 Hz Online Input Voltage Range 79 147 volts Voltage Regulated Output Voltage Range 120 9 On Battery Output Voltage Range 115 5 Output Waveform Line Mode filtered sinewave Out...

Reviews: