Tripp Lite N785-H01-SFP-D Quick Start Manual Download Page 4

4

DIP Switch Setting
Switch Number Label

Description

1

LLB

ON: LLB is enabled

OFF: LLB is disabled

2

LFS

ON: LFS is enabled

OFF: LFS is disabled

3

FX100

ON: Port 2 (SFP) speed at 100 Mbps

OFF: Port 2 (SFP) speed at 1000 Mbps

Switch Category: ALM (Alarm)

4

PWR

ON: Master power alarm reporting is 

enabled

OFF: Master power alarm reporting is 

disabled

5

RPS

ON: Redundant power alarm reporting is 

enabled

OFF: Redundant power alarm reporting 

is disabled

6

LFS

ON: Alarm for LFS issue is enabled

OFF: Alarm for LFS is disabled

LED Indicators

PWR (Green)

ON

Primary power is on

PWR (Green)

OFF

Primary power off or experiencing failure

RPS (Green)

ON

Redundant (Secondary) power is on

RPS (Green)

OFF

Redundant (Secondary) power is off or 

experiencing failure

ALM (Red)

ON

Alarm for following conditions: LFS (Link 

Fault Signaling) alarm; power loss

ALM (Red)

OFF

Normal operation, no LFS alarm or 

power loss

DIP Switch Function and LED Status Table

Summary of Contents for N785-H01-SFP-D

Page 1: ...p Lite All rights reserved Este manual est disponible en espa ol en la p gina de Tripp Lite tripplite com Ce manuel est disponible en fran ais sur le site Web de Tripp Lite tripplite com Quick Start G...

Page 2: ...Signaling LFS and Reserve and FX100 functions Link Fault Signaling LFS LED will immediately illuminate to indicate when a cable has been severed or another cause for disruption has occurred Line Loop...

Page 3: ...Cat5e 6 cable connect the RJ45 port on the media converter to your network 2 Connect a transceiver such as Tripp Lite s N286 Series to the open SFP port on the media converter Then connect fiber cabl...

Page 4: ...power alarm reporting is enabled OFF Redundant power alarm reporting is disabled 6 LFS ON Alarm for LFS issue is enabled OFF Alarm for LFS is disabled LED Indicators PWR Green ON Primary power is on...

Page 5: ...F Copper connection speed at 10 100 Mbps LNK ACT Green ON Blinking Copper port correctly linked LNK ACT Green OFF Copper port link failure SFP SFP Green Amber ON Ethernet link up Green Speed 1000 Mbps...

Page 6: ...rt the terminal block connector accessory which includes PWR and RPS into the terminal block receptor Link Fault Signaling LFS When the LFS DIP Switch is enabled 6 an alarm indicator will illuminate t...

Page 7: ...00Base TX FX 802 3ab 1000Base TX 802 3z 1000Base SX LX 802 3x Flow Control 802 3 Auto Negotiation Power Consumption 5 5W Power Supply Input 20 57V DC Terminal Block Operating Temperature 14 to 140 F 1...

Page 8: ...A PARTICULAR PURPOSE Some states do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOV...

Reviews: