5

Dip Switch Setting 

(continued)

DIP Switch

Dip Function

FX

FDX

FX at full duplex (default)

HDX

FX at half duplex

LFP

Enable Link Fault Pass-Through (default)

LFP DIS 

Disable Link Fault Pass-Through

TP

FDX

TP at full duplex (default)

HDX

TP at half duplex when TP at Force

100

TP at 100M (default)

10

TP at 10M when TP at Force

AUTO

TP at auto-negotiation (default)

FORCE Force TP at 10M or at half duplex

Note: •

You must set DIP Switch 1 to “FORCE” when DIP Switches 2 and 3 are set to “10” and “HDX”, respectively

For N784-001-SC, DIP Switch 5 must be set to “HDX”

After resetting the DIP Switches, you must reboot the Converter to activate the new settings.

Link Fault Pass-Through

Note: The Link Fault Pass-Through (LFP) function is enabled using the DIP switch. Disable the LFP function by
setting the DIP switch to the LFP DIS position.

This media converter supports Link Fault Pass-Through (LFP) for TX/FX converter
applications.

Link status on one port is propagated to the other port to notify remote nodes. If the TP port
is unplugged, the converter stops transmitting over the fiber port, causing the remote fiber
link node to fail. The LED will show link failure on both the TP and fiber ports. If the fiber
link fails, the converter restarts auto-negotiation on the TP port, but stays in the link failure
state. This causes the remote TP node link to fail. The LED also shows the link failure on
both the TP and fiber ports. The figures below show normal status when the link succeeds,
and the error status when TP Cable A, Fiber Cable B, or Fiber Cable C fails to connect.

• Normal status via a pair of LFPs

• Status if TP Cable A is broken

• Status if Fiber Cable B or C is broken

Note: 

indicates LNK/ACT LED Lit    

indicates LNK/ACT LED Off

200605219 93-2565 N784 SMC OM.qxd  6/7/2006  3:54 PM  Page 5

Summary of Contents for N784-001-SC

Page 1: ...Street Chicago IL 60609 USA 773 869 1234 www tripplite com Note Follow these instructions and operating procedures to ensure correct performance and to prevent damage to this unit or to its connected...

Page 2: ...conformity of twisted pair TP Fiber linking to make the network easier to maintain The converter is powered by an external power adapter or USB port on the hosting device e g PC Package Checklist Medi...

Page 3: ...rd against damage due to electrostatic charge Using the Converter with power Over USB 1 Use DIP switch settings to enable power from the USB port refer to DIP switch settings section Note Please ensur...

Page 4: ...e ports and MDI X HUB Switch type ports Also shown are the cable wiring diagrams for straight through and cross over Ethernet cables RJ45 8 pin to RJ45 8 pin Straight Through Cable Wiring Tripp Lite N...

Page 5: ...LFP function by setting the DIP switch to the LFP DIS position This media converter supports Link Fault Pass Through LFP for TX FX converter applications Link status on one port is propagated to the o...

Page 6: ...rs TP LNK ACT Green Lit when TP port is linking Blinks when FX port is transmitting data TP 100 Green Lit when TP port is transmitting data at 100 Mbps Off when TP port is transmitting data at 10 Mbps...

Page 7: ...TRIPP LITE or an authorized TRIPP LITE service center Products must be returned to TRIPP LITE or an authorized TRIPP LITE service center with transportation charges prepaid and must be accompanied by...

Page 8: ...SA 773 869 1234 www tripplite com Copyright 2006 Tripp Lite All rights reserved All trademarks are the property of their respective owners The policy of Tripp Lite is one of continuous improvement Spe...

Reviews: