Isolation Transformer - Medical Grade line noise reduction and spike suppression

 

Highlights

Complete line isolation, noise filtering and surge suppression; ideal for

sensitive equipment

250 watts, 2 outlets, 6-ft. power cord

Hospital-grade plug and receptacles

Leakage current less than 100 microamps

Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule

purchases

Description

 Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode
surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1
medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive
electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels
less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground
reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility
switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression
components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all
modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the
worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V
common mode. Model IS250HG includes 2 NEMA5-15R hospital-grade output receptacles, a 6-ft. power cord, hospital-grade input plug, circuit
breaker overload protection, and lighted power switch. Rugged all-metal unit housing; ships ready for placement in any industrial, medical, office or
network environment. PLUG/OUTLETS: Input - NEMA 5-15P Hospital Grade; Output - 2 NEMA 5-15R Hospital Grade ELECTRICAL: 120V AC,
60Hz, 2.1A (Requires NEMA 5-15R wall receptacle) 

Package Includes

IS250HG Isolation Transformer

Instruction manual with warranty information

Features

The IS250HG Medical Grade Isolation Transformer offers line isolation, continuous noise filtering and enhanced common mode surge

suppression.

Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line

Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles; ideal for the protection of sensitive electronic

equipment in patient-care areas.

Reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps

Secondary neutral-to-ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment

Serves as an inexpensive alternative to dedicated circuits and site electrical upgrades

Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops

Additional surge suppression components placed at the line input and output combined with full line isolation provide continuous filtering of

a full range of power line noise in all modes

Active transformer filtering offers continuous common-mode noise rejection with no wearable parts; unique ability to reduce surges in the

worst of power environments to harmless levels

Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode

Includes 2 widely spaced NEMA 5-15R hospital-grade output receptacles, a 6-ft. power cord, hospital-grade input plug, circuit breaker

overload protection and lighted power switch.