Tripp Lite HCRK-1 Owner'S Manual Download Page 3

3

Battery Module Warnings

• Do not allow objects to contact the Battery Module’s two DC input terminals. Do not short or bridge 

these terminals together. Serious personal injury or property damage could result.

• It is normal for sparks to occur when connecting the Battery Module to the Power Supply Module.

• Due to the possibility of dangerous arcing, do not unplug the Battery Module from the Power Supply 

Module while the Power Supply Module is operating from battery power (whenever the cart is mobile 
and the Power Supply Module is not plugged into a live utility wall outlet).

• Your Battery Module does not require routine maintenance. Do not open your Battery Module for any 

reason. There are no user-serviceable parts inside. The batteries in the Battery Module will eventually 
wear out and be unable to provide adequate backup times. Internal battery replacement must be 
performed by factory authorized service personnel. Because batteries present a risk of electrical shock 
and burn from high short-circuit current, service personnel should observe proper precautions. Unplug 
the Battery Module before performing battery replacement. Do not short or bridge battery terminals with 
any object. Use tools with insulated handles. Remove metal objects such as watches and rings before 
working with batteries. Do not open batteries. Replace batteries only with sealed lead-acid batteries of 
the same number, type, voltage and amp-hour capacity. Contact Tripp Lite for details.

• Tripp Lite offers additional replacement Battery Modules (model #: BP12V82). Contact Tripp Lite 

for details.

• The Battery Module’s internal batteries are recyclable. Refer to local codes for disposal requirements, or 

in the USA only call 1-800-SAV-LEAD or 1-800-8-BATTERY (1-800-8-228-8379) or visit www.rbrc.com 
for recycling information. Do not dispose of the batteries in a fire.

• If connecting a replacement Battery Module to the Power Supply Module, the Battery Module must have 

the same voltage as the Power Supply Module. Use only Tripp Lite Battery Modules 
(model #: BP12V82) with the Power Supply Module.

Labeling Symbols

AC Voltage: V~

DC Voltage: V

Neutral Fusing:

Electric Shock Hazard:

Important Safety Instructions 

continued

Mounting

WARNING!

Mount the Power Supply Module and Battery Module BEFORE connection.

The mounting brackets are only designed to support a Tripp Lite Power Supply Module and a
single Battery Module. Do not mount or place any other devices on the mounting brackets.
The mounting brackets will not support the additional weight and may fail.

Failure to follow these warnings may lead to product damage and/or risk of personal bodily harm.

The mounting bracket is only designed to fit specific mobile medical cart configurations (see diagrams).
Tripp Lite offers additional mounting brackets for additional medical cart configurations. Contact Tripp Lite
for details. The user must determine the fitness of the mounting hardware and procedures before mounting.
If the hardware or procedures are not suitable for your application, contact Tripp Lite for assistance.

200612036 93-2613 Retrofit Kit 1 OM.qxd  12/7/2006  11:06 AM  Page 3

Summary of Contents for HCRK-1

Page 1: ...CSA C22 2 No 601 1 M90 UL 1778 by 1111 W 35th Street Chicago IL 60609 USA 773 869 1234 www tripplite com Copyright 2006 Tripp Lite All rights reserved Important Safety Instructions 2 Mounting 3 Connec...

Page 2: ...all sides of the Power Supply Module and Battery Module for proper ventilation Power Supply Module Connection Warnings Do not operate the Power Supply Module without connecting it to a Battery Module...

Page 3: ...p hour capacity Contact Tripp Lite for details Tripp Lite offers additional replacement Battery Modules model BP12V82 Contact Tripp Lite for details The Battery Module s internal batteries are recycla...

Page 4: ...of the mounting bracket is perpendicular 90 in relation to one of the cart s legs as shown in the Top View diagram Lift and readjust if needed The mounting bracket is designed to accommodate a wide va...

Page 5: ...al adhesive cord management devices are included Use them if desired to keep cords and cables securely stowed after connection 1 2 CAUTION The Power Supply Module features a hospital grade plug If the...

Page 6: ...ule if the total VA ratings for all the equipment you connect exceeds 200VA the Power Supply Module s continuous output capacity To find your equipment s VA ratings look on their nameplates If the equ...

Page 7: ...Power button after reconnection Battery Modules continuously left in a discharged state will suffer a permanent loss of capacity Full recharge time is roughly equal to full discharge time Mobile Oper...

Page 8: ...charge level falls below 30 and shutdown is imminent the alarm will resume again after one minute Once the charge level falls below 30 the user should save open files and safely shut down connected eq...

Page 9: ...ntermittently depending on temperature and load Communications Jacks Connects the Power Supply Module to the Remote User Interface RUI Isolation Transformer Internal Not Shown Ensures full UL 60601 1...

Page 10: ...he Power Supply Module and Battery Module are properly connected Also make sure the Power Supply Module s power cord is plugged into a live AC wall outlet See Connection Start Up section for details R...

Page 11: ...ust have transportation charges prepaid Mark the RMA number on the outside of the package If the unit is within the warranty period enclose a copy of your sales receipt Return the unit for service usi...

Page 12: ...iginal purchaser who must have properly registered the product within 10 days of purchase EXCEPT AS PROVIDED HEREIN TRIPP LITE MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTAB...

Reviews: