![Tripp Lite : B140-002 Owner'S Manual Download Page 7](http://html1.mh-extra.com/html/tripp-lite/b140-002/b140-002_owners-manual_1165400007.webp)
7
Daisy-Chain Installation
(B140-004 only)
Notes:
1) Test to make sure the entire installation works properly before pulling cables through
ceilings/walls.
2) To achieve maximum distance and performance, 24 AWG solid wire Cat5e/6 cable
must be used. The use of stranded wire Cat5e/6 cable, or cable with a gauge (AWG) size
higher than 24 AWG, will result in shorter extension distance. Higher gauge cabling, such
as 26 AWG, has a more limited transmission capability than lower gauge cabling. All
Tripp Lite N202-Series Cat6 cables are made with 24 AWG solid wire. Tripp Lite
N022-01K-GY (Cat5e) and N222-01K-GY (Cat6) are 24 AWG solid wire bulk cables used
in applications that require a 110 punchdown termination.
3) The included 110 Punchdown Tool is provided for your convenience. For best results,
it is recommended that you use a professional 110 Punchdown Installation Tool, such as
Tripp Lite’s N046-000.
Level 1
Level 2
Level 3
OPTIONAL LOCAL
MONITOR
201007212 93-2986.indb 7
9/1/2010 3:48:13 PM