Battery Access
Battery access door
Battery replacement description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 159 to 282VAC
Overvoltage correction
Input voltages between 245 and 282 are reduced by 12%
Undervoltage correction
Input voltages between 159 and 205 are boosted by 14%
LEDS ALARMS & SWITCHES
LED Indicators
2 LEDs indicate power status and overload/check battery status
Alarms
Audible alarm indicates power-failure and overload status
Switches
Combination switch controls on/off power status and self-test operation
SURGE / NOISE SUPPRESSION
UPS AC suppression joule rating
320
UPS AC suppression response time
Instantaneous
UPS Dataline suppression
1 line TEL/DSL (1 in / 1 out)
EMI / RFI AC noise suppression
Yes
PHYSICAL
Installation form factors supported
with included accessories
Tower; Ultra-compact desktop; Wallmount (using keyhole mounting tabs)
Primary form factor
Desktop
UPS / Power Module dimensions in
primary form factor (height x width x
depth / inches)
4 x 12 x 7
UPS / Power Module dimensions in
primary form factor (height x width x
depth / cm)
10.2 x 30.5 x 17.8
UPS / Power Module weight (lbs)
14.8
UPS / Power Module weight (kg)
6.7
UPS Shipping dimensions (height x
width x depth / inches)
5.3 x 14.8 x 9.8
UPS Shipping dimensions (height x
width x depth / cm)
13.5 x 37.6 x 24.9
Shipping weight (lbs)
15.4
Shipping weight (kg)
7
UPS housing material
ABS
ENVIRONMENTAL
3 / 5