Tripp Lite 200803016 95-2924 Technical Application Bulletin Download Page 2

2

Tripp Lite World Headquarters

1111 W. 35th Street, Chicago, IL 60609 USA • (773) 869-1234 • www.tripplite.com

PDU Selector Guide (Input/Output)

Choose by matching power source input to PDU output.

Using a Tripp Lite UPS System 
as Power Source Input

The most common application for a PDU is to distribute UPS System power to connected
computer equipment. The table below shows common outlet types and a partial list of 
Tripp Lite UPS Systems that include each outlet type.

OUTLET SMARTPRO 

SMARTONLINE 

TYPE

UPS SYSTEMS

UPS SYSTEMS

5-15R

All 500-3000VA (120V)

All 750-3000VA (120V)

5-15/20R

All 2200-5000VA (120V)

All 2200VA-16kVA (120V) 

L5-20R

Select 2200-2600VA (120V)

All 2200VA (120V) 

L5-30R

All 3000VA (120V)

All 3000VA (120V)

L6-20R

Select 5000VA

All 5000VA and Select 6-16kVA

L6-30R

All 5000VA

All 5000VA and Select 6-16kVA

C13

All International Versions

All International Versions

C19

All 2200-5000VA International Versions

All 2200-3000VA International Versions

* 5-20R wall outlets and 5-15/20R PDU outlets accept 5-15P or 5-20P plugs. ** Model includes ATS. 

User provides input cable for this application.

PDU Part Number Decoder

PDU = Power Distribution Unit
M = Metered
H = Horizontal
V = Vertical
AT = ATS with Redundant Input Cords
NET = Network Card for Remote 

Monitoring and Control

HV = High Voltage (200-250V)

Tripp Lite Power Cords and Adapters

Model

Description

P002-002

C14 to 5-15R Power Cable (2 ft.)

P004-006

C13 to C14 Power Cable (6 ft.)

P005-010

Heavy-Duty C13 to C14 Power Cable (10 ft.)

P006-006

C13 to 5-15P Power Cable (6 ft.)

P007-010

Heavy-Duty C13 to 5-15P Power Cable (10 ft.)

P010-012

C13 to 5-15P Power Cable (12 ft.)

P022-001

5-15R to 5-15P Power Cable (1 ft.)

P032-007

C13 to C20 Power Cable (7 ft.)

P034-010

Heavy-Duty C19 to 5-15P Power Cable (10 ft.)

P040-010

C19 to L6-20P Power Cable (10 ft.)

P044-06I

L5-20R to 5-20P Adapter (6 in.)

P045-010

Heavy-Duty C19 to L5-20P Power Cable (10 ft.)

P047-010

Heavy-Duty C14 to C19 Power Cable (10 ft.)

P049-010

Heavy-Duty C19 to 5-20P Power Cable (10 ft.)

UNIPLUGINT

C13 to Wonpro Universal Outlet Adapter (Wonpro outlet is compatible with
more than 20 North American and international plug types.)

Step 1

Step 2

Choose Power Source Input

Choose PDU Output

Receptacle Type

Voltage

Current

Basic PDUs

Metered PDUs

Switched PDUs

Model

Outlet

Outlet

Model

Outlet

Outlet

Model

Outlet

Outlet

Number

Qty.

Type*

Number

Qty.

Type*

Number

Qty.

Type*

5-15R

100-125V

15A

PDU1215

13

5-15R

PDUMH15

13

5-15R

PDUMH15ATNET**

8

5-15R

PDU1415

14

5-15R

PDUMV15

16

5-15R

PDUMV15NET

16

5-15/20R

PDUNV

14

2 C19 / 12 C13

PDUMH15AT**

8

5-15R

PDUV15

12

5-15R

5-20R*

100-125V

20A

PDU1220

13

5-15/20R

PDUMV20

20

5-15/20R

PDUMH20ATNET**

16

5-15/20R

PDUNV

14

2 C19 / 12 C13

PDUMV40

32

5-15/20R

PDUMV20NET

24

5-15/20R

PDU40TDUAL 40

5-15/20R

PDUMH20AT** 16

5-15/20R

PDUV20

12

5-15/20R

PDUMH20

13

5-15/20R

L5-20R

100-125V

20A

PDU1220T

13

5-15/20R

PDUMV20

20

5-15/20R

PDUMH20ATNET**

16

5-15/20R

PDU1420T

14

5-15/20R

PDUMV40

32

5-15/20R

PDUMV20NET

24

5-15/20R

PDU40TDUAL 40

5-15/20R

PDUMH20AT** 16

5-15/20R

PDUNV

14

2 C19 / 12 C13

PDUMH20

13

5-15/20R

L5-30R

100-125V

30A

PDU2430

24

5-15R

PDUMV30

28

5-15/20R

PDUMV30NET

24

5-15/20R

PDUMH30NET

16

5-15/20R

L6-20R

200-250V

20A

PDUNV

14

2 C19 / 12 C13

PDUMV20HV

38

6 C19 / 32 C13

PDUMV20HVNET

24

4 C19 / 20 C13

L6-30R

200-250V

30A

PDU1230

18

2 C19 / 16 C13

PDUMV30HV

30

6 C19 / 24 C13

PDUMV30HVNET

24

4 C19 / 20 C13

PDUV30HV

38

6 C19 / 32 C13

PDUMH30HVNET

16

C13

C13

Varies

Varies

PDUNV

14

2 C19 / 12 C13 

PDUMH15HVNET

8

C13

C19

Varies

Varies

PDUNV 

14

2 C19 / 12 C13

PDUMH20HVNET

8

C13

PDUMV20HVNET

24

4 C19 / 20 C13

VARIES

Varies

Varies

PDU12IEC

14

2 C19 / 12 C13

PDUMV20HV

38

6 C19 / 32 C13

PDUMV20HVNET

24

4 C19 / 20 C13

(User provides 

PDUMH15ATNET**

8

5-15R

C19 or C13, 

PDUMH20ATNET**

16

5-15/20R

depending on 

model, to the input 

plug of their choice.)

Summary of Contents for 200803016 95-2924

Page 1: ...put Cords and Dual Independent Power Circuits PDU Selector Guide Features Benefits Choose a PDU by identifying the ideal features and benefits for your application Tripp Lite PDUs Basic PDUs Metered P...

Page 2: ...10 ft P044 06I L5 20R to 5 20P Adapter 6 in P045 010 Heavy Duty C19 to L5 20P Power Cable 10 ft P047 010 Heavy Duty C14 to C19 Power Cable 10 ft P049 010 Heavy Duty C19 to 5 20P Power Cable 10 ft UNI...

Page 3: ...UPS system from 8 to 32 in this example additional 12 front panel outlets not shown 2 1 Application 3 Remotely Controlling Individual Outlets via SNMP Web or Telnet Applicable Tripp Lite PDUs All Swit...

Page 4: ...15A 1 x 15A 5 15P 14 5 15R n a 14 15 ft 1 75 x 25 75 x 2 25 n a PDU1420T 120V 20A 1 x 20A L5 20P 14 5 15 20R n a 14 15 ft 1 75 x 25 75 x 2 25 n a PDU40TDUAL 120V 2 x 20A 2 x 20A L5 20P 5 20P 2 B 40 5...

Page 5: ...120V 20A 1 x 20A L5 20P 5 20P C 13 5 15 20R 1 12 15 ft 1 75 x 17 5 x 4 5 PDUMV15 120V 15A 1 x 15A 5 15P 16 5 15R 16 n a 15 ft 1 5 x 48 x 1 5 n a PDUMV20 120V 20A 1 x 20A L5 20P 5 20P C 20 5 15 20R 20...

Page 6: ...put Current Meters Type Qty Type E Length H x W x D in Rackmount Mount Mount Horizontal Models PDUMH15ATNET 120V A 15A 1 x 15A 5 15P 8 5 15R 2 x 12 ft 1 75 x 17 5 x 14 5 1U PDUMH20ATNET 120V A 20A 1 x...

Page 7: ...Twist Lock L5 20P to Straight Blade 5 20P Plug Adapter C14 or C20 Power Inlet Cord Retention Bracket J I H G F E D C B A F B E D G C A F B E D G C A D FEATURES PDUMH15ATNET PDUMH20ATNET H Switched PDU...

Page 8: ...ng range 99 138V and 45 65 Hz 3 2 1 PDUs with Dual Independent Power Circuits Dual Independent Power Circuit PDUs provide an efficient and manageable power distribution solution for multiple servers w...

Reviews: