Response 
Time 

 

IR Temperature: 0.5 seconds; Probe Temperature 
and Relative 

 

 

Humidity: 3 minutes 

 

 

Accuracy note 

 

Accuracy is specified for the following ambient 
temperature range: 18 to 

 

 

28°C (64 to 82°F) 

 

 

Sampling 
Rate 

 

2.5 samples per second 

 

 

InfraRed 
Emissivity 

 

0.95 (fixed) 

 

 

IR Field of 
View 

 

D/S = Approx. 8:1 ratio (D = distance, S = spot) 

Laser power 

 

Less than 1mW 

 

 

IR Spectral 
Response 

6 to 14  m (wavelength) 

 

 

Operating 
Conditions 

0 to 50

o

C (32 to 122

o

F); < 80% RH non-condensing 

Storage 
Conditions 

 

-10 to 60

o

C (14 to 140

o

F); <80% RH non-condensing 

Power Supply 

 

9V Battery with auto power off (after 10 minutes) 

Battery Life 

 

Approx. 24 hours (if Backlight and Laser are used 
continuously the 

 

 

battery life is reduced to 2 to 3 hours approx.) 

Dimensions / 
Weight 

150 x 72 x 35mm (5.9 x 2.8 x 1.4”); 235g (8.3 oz) 

 
Emissivity 

 

Most organic materials and painted or oxidized surfaces have an 
emissivity of 0.95 (fixed setting in the model RHT70). Inaccurate 
readings will result when measuring shiny or polished surfaces. To 
compensate, cover the surface under test with masking tape or flat black 
paint. Allow time for the tape to reach the same temperature as the 
material underneath then measure the temperature of the tape or the 
painted surface. 

 
 
 
 
 
 

Summary of Contents for RHT70

Page 1: ...User Manual RHT70 Hygro Thermometer IR Thermometer...

Page 2: ...r for convenient targeting Safety Use extreme caution when the laser pointer beam is on Do not point the beam toward anyone s eye or allow the beam to strike the eye from a reflective surface Do not u...

Page 3: ...s represent Air Probe Temperature Indicates that the laser pointer is on IR TEMP Indicates that the larger LCD digits represent IR temperature measurement MAX bottom of LCD Max Hold for the IR Tempera...

Page 4: ...ed 3 Press and hold the large red IR button to begin measuring the surface temperature of a desired target IR TEMP and will appear on the display The laser pointer will switch on to help aim the meter...

Page 5: ...ote that in IR temperature mode Data Hold is automatically engaged when the red IR button is released MAX Buttons Press the MAX button bottom of meter for Air Temperature center of meter for IR temper...

Page 6: ...ments To find a hot spot aim the meter outside the area of interest then scan across in an up and down motion until the hot spot is located IR Theory IR thermometers measure the surface temperature of...

Page 7: ...of the meter 4 Remove the small Phillips head screw on the rear of the meter 5 Open the battery compartment and replace the 9V battery 6 Re assemble the meter before operating Never dispose of used ba...

Page 8: ...chamber or humidity calibration bottle and wait 20 minutes 3 Turn the meter on and turn the adjustment until the humidity reading on the display agrees with the calibration source Specifications Funct...

Page 9: ...80 RH non condensing Power Supply 9V Battery with auto power off after 10 minutes Battery Life Approx 24 hours if Backlight and Laser are used continuously the battery life is reduced to 2 to 3 hours...

Page 10: ...f purchase This warranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as in our sole judg...

Reviews: