16
Triple Solar assembly instruction PVT heat pump panels March 2020
Figure 7.2-e middle clamp prepared
Let op:
The cut-outs on both sides of the middle clamp must fall over the upright ridges of the panels!
This is to ensure the locking of the connecting hoses, see figure 7.3d + 7.3e.
Figure 7.2-f cross-section of attached connecting hose and middle clamp.
Mounting the TS clamping profile
Now that the whole row of panels is in place and it has been checked that the alignment of the panels is
correct, it is time to connect TS clamping profiles to the panels.
1) Slide the TS clamping profile (#311000) sideways (in the longitudinal direction of the mounting
rails) over the middle support of the panel until it clicks into the panel profile, see figure 7.4-a.
2) Secure the TS clamping profile by bending the ridge upwards, indicated by a C. in figure 7.4-b.
Figure 7.2-d middle clamp fixed