8.

  Release the red button approximately 6 inches

 

be-

fore completing each pass

.  The spray jets are located 

behind the vacuum head making it  necessary to pull the 

machine a few inches further to pick up the last amount 

of solution dispensed onto the carpet.

9.

  Tilt the machine back on the rear wheels and

 

walk 

forward

 to position the machine along side the previous 

pass (slightly overlapping).

10.  As

 

dirty solution is recovered, some foaming may be 

noted.  Excessive foaming can be counteracted with 

liquid  defoamer  applied  according  to  the  chemical 

manufacturing directions.  

Do not allow foam to rise 

into or near the dome; this will harm the vacuum 

motor.   

Use defoamer or empty and flush the recovery 

tank.

11.  To 

empty the recovery tank

, remove the dome as-

sembly and lift the tank out.  Dispose of the recovered 

water properly. 

12.

  If streaking occurs

 after a period of operating time, 

this means the solution (fresh water) tank is near empty.  

Streaking  is  eliminated  by  adding    more  water  and 

chemical solution to the tank.  

Empty the recovery 

tank every time you fill the solution tank.

13.  To

 empty the solution tank

 connect the Power Fill 

adaptor to the vacuum inlet on the front of the dome.  

Turn the vacuum switch on. 

5.    Make sure the brush assembly lift lever is locked in the 

raised position.

6.   Store your machine in a dry, protected area.  

Do not 

expose this machine to rain, standing water or freez-

ing temperatures.

Periodically:

After continuous or repeated use the 

jets and check valves 

will need cleaning:  Unplug the cord and empty the recovery 

and solution tanks.  Tilt the machine backward.  Remove 

the jet caps, jets and check valves shown in the brush as-

sembly illustration and soak in white vinegar until visible 

deposits are dissolved, then scrub with a soft bristle brush.  

Note:  jets and check valves should be replaced once a 

year,

 because they tend to erode under extended use.  This 

may cause overuse of solution and streaking.

  

After Each Use:

1.  Clean the dome top, intake filter screen, gasket and 

recovery tank with fresh, clean water.  Do not reinstall 

the dome until the next use, this will allow the recovery 

tank to dry out.

2.  Flush the solution tank and inlet screen with clean water.  

Vacuum all water out using the Power Fill adaptor.

3.  Remove any debris on the scrub brush, vacuum head 

and around the spray jets.

5

The ACHIEVER 40 self-contained extractor is designed 

and manufactured to provided years of trouble free service 

with a minimum of maintenance and service.  The follow-

ing recommendations are intended to assist the operator and 

Service Technician in performing routine maintenance.

WARNING:  Always unplug your machine before per-

forming any service.  Severe personal injury could result 

if the electrical power is not disconnected.

OPERATING WITH ACCESSORY TOOLS

1.  To use an accessory tool disconnect the supply hose at 

the rear of the machine and connect the accessory tool 

hose . 

2.  Next, disconnect the machine’s vacuum hose from the 

front of the dome assembly and connect the accessory 

tool vacuum hose to the dome.

3.  Turn  the  vacuum  and  accessory  pump  switches  on.  

Solution will be dispensed while the accessory tool 

trigger is depressed.

Watch the dome to make sure the recovery tank does 

not overflow.

Note:   The  pump  motor  is  equipped  with  an  automatic 

thermal protection device.  If the motor overheats for any 

reason, the thermal protector will activate and automati-

cally turn the motor off.  If this occurs the operator should 

turn the manual pump switch to the off position and allow 

approximately fifteen minutes for the motor to cool.  When 

the motor has cooled to a safe operating temperature, the 

thermal protector will automatically close and allow power 

to be supplied to the motor via the manual pump switch.  

The operator will be able to resume normal operation.  If 

the pump motor shuts down repeatedly, it should be checked 

at an Authorized Service Center.

SERVICING

OPERATING PROCEDURES

Summary of Contents for ACHIEVER 40

Page 1: ...ite www triple s com or write to Triple S 2 Executive Park Drive Billerica MA 01862 Carefully inspect all components to ensure that there is no concealed freight damage If such damage is discovered le...

Page 2: ...s and ordinances WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a quali ed electrician or service person if you are in doubt as to w...

Page 3: ...hat is protected by a ground fault circuit interrupter Consult your electrical contractor 10 To prevent damage to the power cord do not move this machine over the power cord Always lift the power cord...

Page 4: ...ons of water Then ll the tank with warm water using the faucet power ll adaptor Do not use water hotter than 60 C 140 F Or you may mix the concentrate with 3 to 3 1 2 gal lons of clean water in a CLEA...

Page 5: ...ode under extended use This may cause overuse of solution and streaking After Each Use 1 Clean the dome top intake lter screen gasket and recovery tank with fresh clean water Do not reinstall the dome...

Page 6: ...unting bolts with a 7 16 wrench DO NOT REMOVE THE BOLTS UNLESS YOU ARE REPLACING THE MOTOR Slide the motor away from the brush to tighten the belt or toward the brush to remove If you are replacing th...

Page 7: ...7 Achiever 40 Wiring Diagram...

Page 8: ...Achiever 40 Drawing 1 8 03 01...

Page 9: ...witch CSA 1 17 203970 Handle Lift Bracket 1 49 911089 Switch Rocker 2 18 W136D Screw 8 x 1 2 8 50 206670 Plate Switch 1 19 202470 Catch Brush Lift 1 51 911147 Terminal Block 1 20 201374 Body Machine 1...

Page 10: ...Achiever 40 Drawing 2 03 01...

Page 11: ...46 S982P Jet 11004 Brass 2 13 W169D Screw 1 4 20 x 1 2 HH CS SS 6 47 S973P Cap Jet 2 14 204181 Hose 1 48 Brush Assembly Complete 1 15 240202 Adaptor Hose to Dome 1 49 962062 Screw 6 4 16 244107 Hose...

Page 12: ...o provide you and all users of the SSSAchiever 40 with information concerning the duration extent availability and applicability of this Limited Warranty the procedure to be taken to obtain its perfor...

Reviews: