Trion MA1200 Installation, Operation And Service Download Page 10

TRION AIR BOSS Mist Arrestor 3-Stage Mist Collector

Specifications Data Table

MA 600

MA 1200

Dimensions:

74.2” L x 27.6 ” W x 333.1” H

70.3” L x 27.6 ” W x 35.8” H

1885mm x 700mm x 840mm

1785mm x 700mm 910mm

Weight:

331 lbs/ 150 kg

437 lbs/ 198 kg

Motor:

3 Hp / 2.2kw

4 Hp / 3.0kw

Amp Draw:

208V – 8.8 amps

208V – 11.9 amps

230V – 7.9 amps

230V – 10.7 amps

460V – 4.0 amps

460V -   5.4 amps

Air Inlet

Single 6” Diameter 

Single 8” Diameter

Air Volume:

600 CFM @ 6.0” SP

1200 CFM @ 6.0” SP

Sound Rating:

72 dBa

72 dBa

Filters:

Prefilter

Washable 12 Layer Coalescing Filter-99% @ 2 micron size +
Initial Resistance: 2.75” w.g.  

Final Resistance: 4.0” w.g.

12” x 12” x 4.0”

12” x 24” x 4.0”

295 x 295 x 80mm

295 x 595 x 80mm

Secondary

Washable 7 Layer Coalescing Filter-99% @ 10 micron size +
Initial Resistance: 0.4” w.g.  

Final Resistance: 1.25” w.g.

12” x 24” x 5.5”

24” x 24” x 5.5”

295 x 595 x 150mm

595 x 595 x 150mm

Primary

Mini-Pleat Extended Surface Filter, 98% Ashrae, 194 sq.ft. media
Initial Resistance: 0..56” w.g.  

Final Resistance: 2.0” w.g., Class 2

12” x 24” x 12”

24” x 24” x 12”

292 x 592 x 292mm

592 x 592 x 292mm

Common Specifications:

Cabinet:

16 gauge Galvanized Steel

Doors:

Gasket sealed, Hinged Access doors on primary, secondary
and final filters and blower access compartment.

Drain:

3 / 4” NPT x 2” centered behind secondary filter

Finish:

Textured Reverse Blue, Baked on Oil Resistant Paint

Installation:

Ducted to Platform or Frame Mounted

Manometer Gage: Installed with 2 each Manometer Pressure Gage Kit, 0-6.4” wg
Electrical:

208-230/460V/60Hz/3 PH, junction box provided

Blower:

Direct Drive centrifugal

Blower Access: 

Removable Rear Panel and side access door

Options:

Controls:

Motor Starter provided by Customer

FIG. 3

Summary of Contents for MA1200

Page 1: ...le free operation and to get the most of your purchase For further information concerning this product contact your local Trion representative Media Air Cleaning Systems for Commercial and Industrial...

Page 2: ...CTION 3 PREPARATION INSTALLATION 3 SUSPENSION MOUNTING 4 WIRING 4 UNIT OPERATION 4 MAINTENANCE 4 FILTERS 5 CLEANING INSPECTION OF CABINET 5 TROUBLESHOOTING 7 ORDERING REPLACEMENT PARTS 5 TROUBLESHOOTI...

Page 3: ...on of the contaminants will vary depending on the environment The contaminants may be in the form of smoke airborne dirt from outside small particles of grease mist or moisture The size of the particl...

Page 4: ...tage can be changed to 208 0r 230 60 3 at the motor junction box The unit data label supplied in literature package is to be marked for application voltage and affixed adjacent to the unit junction bo...

Page 5: ...cleaned and must be replaced when dirty Contact your local Trion representative for replacement filters CLEANING INSPECTION OF CABINET CAUTION TO CHECK INTERNAL COMPONENTS TURN UNIT POWER OFF After th...

Page 6: ...t Arrestor Filter 12x24x5 5 Secondary Filter 346618 025 Mini Pleated Extended Final Filter 12x24x12 MA1200 Unit 356329 001 Mist Arrestor Filter 12x12x4 Pre Filter 2 required 356329 003 Mist Arrestor F...

Page 7: ...R TURNS FREELY 3 FAULTY MOTOR 4 INCORRECT SUPPLY VOLTAGE CHECK FOR 1 AIR BYPASSING FILTERS 2 HOLES IN FILTERS 3 DIRT ON MOTOR CAUS ING OVERHEATING 4 FILTERS MISSING 5 ACCESS DOORS NOT FULLY CLOSED 6 I...

Page 8: ......

Page 9: ......

Page 10: ...on size Initial Resistance 0 4 w g Final Resistance 1 25 w g 12 x 24 x 5 5 24 x 24 x 5 5 295 x 595 x 150mm 595 x 595 x 150mm Primary Mini Pleat Extended Surface Filter 98 Ashrae 194 sq ft media Initia...

Page 11: ......

Page 12: ...s of such defective air cleaners 6 This limited warranty does not apply to any part or component that is damaged in transit when handling has been subject to misuse neglect or accident has not been in...