T1001/T2002 Problems and Possible Causes
1. Indicating Light Out
a. Unit not plugged in
b. Control switch “Off”
c. Cell access panel not fully closed
d. Broken cell insulator
e. Extremely dirty cells
f. Service panel not secured in place
2. Excessive arcing noise after washing
a. Collector elements still wet – Allow more drying time
b. See “Continuous arcing noise” below
3.
Continuous arcing noise and flickering indicating light
a. Extremely dirty collector plates
b. Bent collector plates
c. Large piece of material lodged between cell plates
4. Contaminant Bypass
a. Velocity of airflow is too high through unit
b. Collector plates not grounded
c. Collector cell not making solid connection to
access door and high voltage contact
IF PROBLEM CANNOT BE DETERMINED OR
CORRECTED - CONTACT YOUR LOCAL TRION
REPRESENTATIVE OR CALL TRION CUSTOMER
SERVICE AT 1-800-884-0002 FOR ASSISTANCE.
T1300/T2600 Problems and Possible Causes
The troubleshooting chart, shown on the next page, will
enable the user to pinpoint the cause of most problems.
Refer to the Ordering Information for replacement
parts. Before performing any troubleshooting, ensure
the correct input line voltage is present.
T-Series
7
I n s t a l l a t i o n , O p e r a t i o n , & S e r v i c e M a n u a l
Warranty
Troubleshooting Guide
WARNING
Factory designed access to all electrically
charged high voltage components contain
electrical interlocks for the safety of operating
personnel. Always unplug the unit while
performing service within the cabinet.