background image

11

Quick Start Guides 

200.35mm

146.35mm

138mm

192mm

42.55mm

R2mm

CUTOUT DIMENSIONS

A

C

B

D

E

G

F

H

I

K

J

UNIPLAY 7

DIMENSIONS AND PORTS

A

DIP switch & reset button 

G

Com1 RS485, Com3 RS485, Com3 RS232

B

Fuse

H

Com1 RS232, Com2 RS232

C

Power connector

I

Ethernet port

D

VESA 75mm screw holes

J

USB Host port

E

Line out

K

USB Client port

F

SD card slot

Summary of Contents for UNIPLAY 10

Page 1: ...1 Quick Start Guides UNIPLAY HMI QUICK CONNECTION GUIDE...

Page 2: ...n Perfect v3 version greater than 3 1 0 5544 2 UNIPLAY 7 or UNIPLAY 10 HMI panel 3 MC4XX Motion Coordinator with system software 2 0199 or higher USING UNIPLAY UNIPLAY HMI s work with the Trio 4xx Mot...

Page 3: ...3 The HMI panel must be aware of the Motion Coordinator IP address If this is not at default use MPv3 Tools Setup UNIPLAY HMI device screen to store the Motion Coordinator IP address into the panel 4...

Page 4: ...under Add New Program and give the page a name The new blank page will open in the editor The components on the left hand column can be dragged and dropped on the page The top border tools are used t...

Page 5: ...omponent property to controller data click on the small chain bitmap alongside each property The menu then lets you choose what type of controller data to link to This can be a program variable for ex...

Page 6: ...ograms Note how one HMI screen is set to be the Start up page This is the first page that will be displayed and is highlighted in bold in the program tree You can select a different page to be the Sta...

Page 7: ...nal software installation is required to use the UNIPLAY HMI system Installation of any additional software on the device by users will invalidate the warranty INSTALLATION ENVIRONMENT The UNIPLAY is...

Page 8: ...Allow a clearance of 25mm around the sides of the unit for mounting hardware Allow clearance for cable connections to the back of the unit Unit depth may vary according to cable type used Typically pl...

Page 9: ...es should be run in pairs with a neutral or common paired with a signal line If wiring is to be exposed to lightning or surges use appropriate surge suppression devices Keep a c high energy and rapidl...

Page 10: ...l and thereby create an unsafe condition Furthermore electrical interference in an operator interface such as a UNIPLAY can lead to equipment start up which could result in property damage and or phys...

Page 11: ...IMENSIONS A C B D E G F H I K J UNIPLAY 7 DIMENSIONS AND PORTS A DIP switch reset button G Com1 RS485 Com3 RS485 Com3 RS232 B Fuse H Com1 RS232 Com2 RS232 C Power connector I Ethernet port D VESA 75mm...

Page 12: ...97mm 212 97mm 201mm 259mm 50mm R2mm CUTOUT DIMENSIONS A C B D E G F H I K J UNIPLAY 10 quick start v3 November 2012 UK USA CHINA INDIA WWW TRIOMOTION COM B R E A T H I N G L I F E I N T O M A C H I N...