background image

This machine must be grounded.

 If it should malfunction or break down,

grounding provides a path of least resistance for electric current to reduce the
risk of electric shock. This appliance is equipped with a cord having equipment
grounding conductor and grounding plug. The plug must be inserted into an
appropriate outlet that is properly installed and grounded in accordance with
all local codes and ordinances.

WARNING:

Improper connection of the equipment grounding conductor can

result in a risk of electric shock. Check with a qualified electrician or service
person if you are in doubt as to whether the outlet is properly grounded. Do not
modify the plug provided with the appliance – if it will not fit the outlet, have a
proper outlet installed by a qualified electrician.

***Warranty is voided by removal of grounding pin***

Extension Cord Usage Chart

 Total Extension Cord Length (Feet)

Rating-Amps

25   50   75   100   125   150   175   200

  0-10.0                18   18    16    16     14     14     12     12
10.1-13.0             16   16    14    14     14     12     12     12

 13.1-15.0             12   12    12    12     12     12     12     –

GROUNDING INSTRUCTIONS

This appliance is for use on a nominal 120- Volt circuit, and has a grounded plug  that
looks  like  the  plug  illustrated  in

sketch  A

  above.  A  temporary adapter that looks like

the adapter illustrated in

sketch B

 may be used to connect this plug to a 2-pole

receptacle as shown in

sketch B

 if a properly grounded receptacle is not available.

The temporary adapter should be used only until a properly grounded outlet

 sketch A

can be installed by a qualified electrician. The green colored ear, lug, or the like
extending from the adapter must be connected to a permanent ground such as a
properly grounded outlet box cover. Whenever the adapter is used, it must be held in
place by a metal screw.

NOTE:

 In Canada, the use of a temporary adapter is not

permitted by the Canadian Electrical Code.

7

8

START UP:

Before starting your Trinity machine for the first time,  you will need to be sure
the inverter box is set low (around 50) before you even turn your machine on.

1) Turn on the Trinity machine FIRST
2) Turn on the inverter
3) Slowly increase inverter speed until at desired level (50 - 80 is average
starting range but increase as needed depending on job).

TURN OFF INVERTER:

1) Turn speed down low (approx 50)
2) Turn off Trinity machine

WARNING!!

NEVER OPEN THE INVERTER BOX FOR ANY REASON!

DOING SO WILL VOID YOUR WARRANT

Y

Genesis KBAC Series Inverter

Power Status Button:

Green

 - running fine

Red

- problem

**If your button is

red

, turn down speed.

It may be running too aggressive too
Quickly so back the machine down
until button turns green again.

Speed Control:

Controls the speed at which the motor
turns.

Momentary On/Off:

Machine will not start unless
this is on

INVERTER

A

B

Summary of Contents for Champ

Page 1: ...stems com General Info Questions 859 744 5332 info trinityrenewalsystems com Machine Sales Info ask for Charles 859 771 5716 or 859 744 5369 Charles trinityrenewalsystems com Trinity Renewal Systems 7890 Mt Sterling Road Winchester KY 40391 Office 859 744 5332 info trinityrenewalsystems com www trinityrenewalsystems com ...

Page 2: ...1 Counter balance 12 Bell 13 Spray Pump 14 Motor plate pillow block bearings after 2 sets must determine cause 15 Inverter as long as inverter box has not been opened or tampered with ONE YEAR LIMITED WARRANTY If you encounter a problem with your machine contact Trinity Renewal Systems International Inc 7980 Mt Sterling Road Winchester KY 40391 859 744 5332 trscustomerservices gmail com Basic safe...

Page 3: ...Y WAY THE WARRANTY IS IMMEDIATELY VOID SAFETY PRECAUTIONS IMPORTANT As soon as your new machine arrives look it over to be sure it arrived in the same condition it was shipped in pristine Make sure the shipping box is in good condition and free of gouges and big dents Once you have determined there were no freight issues you will need to do a few simple set up measures BEFORE USING YOUR MACHINE to...

Page 4: ... be ready to clean as soon as you put chemical in the jug The Trinity machine is a walk and go machine You simply walk and push the spray button at the same time The Trinity will easily clean in one pass unless it is a very high traffic area or an extremely greasy or heavily soiled carpet If for some reason liquid is not coming out or barely coming out when you push the spray button you will need ...

Page 5: ...tch B may be used to connect this plug to a 2 pole receptacle as shown in sketch B if a properly grounded receptacle is not available The temporary adapter should be used only until a properly grounded outlet sketch A can be installed by a qualified electrician The green colored ear lug or the like extending from the adapter must be connected to a permanent ground such as a properly grounded outle...

Page 6: ...dirt debris and any left over chemical If you notice your machine rattling or making any unusual noise with the machine on run your hand down the handle and hold the machine where the problem seems to be coming from In the area you have pinpointed check all screws bolts bearings ect To be sure everything is tight and that nothing is broken or missing Also check the pad driver bearing to be sure th...

Page 7: ... close to over 2 years old If yes you probably need a new one If not check the pad driver to be sure there is no black grease and the bearing is tight in the Oring See pg 14 If you are still unable to pinpoint problem get as close to the area as possible and take a video of the area with the sound on and email to us PAD DRIVER SEEMS LOOSE Q Pad driver with red bristles seems to be loose and or wob...

Reviews: