Triner Scale TS60-1010 Assembly Manual Download Page 19

 

 

 

TRINER SCALE & MFG. CO. 

    LIMITED WARRANTY 

What is Covered

:

 Triner Scale & Mfg. Co. Inc. warrants to the first end user customer of the Triner Scale product 

enclosed with this limited warranty statement that the product, if purchased and used in the United States, 
conforms to the manufacturer’s specifications and will be free from defects in workmanship and materials for a 
period of two (2) years from the date of original purchase.  
 

What Triner Scale Will Do to Correct Problems:

 

Should your Triner Scale product prove defective during the 

warranty period, please call Triner Scale at (800) 238-0152 for warranty repair instructions and return 
authorization. Triner Scale will, at its option, repair or replace on an exchange basis the defective unit as follows: 
 
PARTS 
New or comparable rebuilt parts in exchange for defective parts for one (1) year after the date of original 
purchase. 
 
LABOR 
Carry-In or mail in service for six (6) months from the date of original purchase. Labor and shipping cost after the 
six-month period will be charged to you. 
 
If you are authorized by Triner Scale to ship the product to Triner Scale for repair, it is your responsibility to 
securely package the product in its original container or an equivalent and provide proof of the date of original 
purchase. You will be responsible for shipping costs to Triner Scale repair facility. When warranty service involves 
the exchange of the product or a part, the exchanged product may be new or previously repaired to the Triner 
Scale standard of quality. Exchange or replacement products or parts assume the remaining warranty period of 
the product covered by this limited warranty. 
 

What this Warranty Does Not Cover

:

 This warranty covers only consumer use in the United States. Triner Scale 

is not responsible for warranty service should the Triner Scale label or logo or the serial number be removed or 
the product fail to be properly maintained or fail to function properly as a result of misuse, abuse, improper 
installation, neglect, improper shipping, damage caused by disasters such as fire, flood, and lightning, improper 
electrical current, interaction with non-Triner Scale products, or service other than a Triner Scale Authorized 
Service. Packaging and shipping costs incurred in presenting your Triner Scale product  for warranty service are 
your responsibility. If a claimed defect cannot be identified or reproduced in service, you will be held responsible 
for costs incurred. 
 

ANY MODIFICATION OF ANY COMPONENT OTHER THAN FACTORY PERFORMED OR FACTORY 
APPROVED WILL RENDER THIS WARRANTY NULL AND VOID. 

 
THE WARRANTY AND REMEDY PROVIDED ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER 
EXPRESS OR IMPLIED WARRANTIES INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SOME LAWS DO NOT ALLOW THE 
EXCLUSION OF IMPLIED WARRANTIES. IF THESE LAWS APPLY, THEN ALL EXPRESS AND IMPLIED 
WARRANTIES ARE LIMITED TO THE WARRANTY PERIOD IDENTIFIED ABOVE. UNLESS STATED HEREIN, 
ANY STATEMENTS OR REPRESENTATIONS MADE BY ANY OTHER PERSON OR FIRM ARE VOID. 
EXPECT AS PROVIDED IN THIS WRITTEN WARRANTY, NEITHER TRINER SCALE & MFG. CO. INC. NOR 
ITS AFFILIATES SHALL BE LIABLE FOR ANY LOSS, INCONVENIENCE, OR DAMAGE, INCLUDING DIRECT, 
SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES, RESULTING FROM THE USE OR INABILITY TO 
USE THE TRINER SCALE PRODUCT, WHETHER RESULTING FROM BREACH OF WARRANTY OR ANY 
OTHER LEGAL THEORY. 
 
No terms, condition, understanding, or agreements, purporting to modify the terms of this warranty shall have any 
legal effect unless made in writing and signed by a corporate officer of the seller. This warranty gives you specific 
legal rights, and you my have other rights which vary from jurisdiction to jurisdiction. 

 

                                  TRINER SCALE & MANUFACTURING COMPANY INC. 
                                                          

8411 Hacks Cross Road 

                                                          Olive Branch, MS 38654-4010 
                                                    Tel (662) 890-2385 

 Fax (662) 890-2386

 

Summary of Contents for TS60-1010

Page 1: ...ASSEMBLY GUIDE TS60 1010 Platform Scale Series 2 V 2 0...

Page 2: ...Securely Bolt Down the Entire Weighing Deck Side Rails Assembly 4 7 Attach and Securely Fasten the Two Guard Rails 5 8 Connect All Load Cell Cables Into the Junction Box Terminals 5 9 Connect the Dig...

Page 3: ...lift is required during scale assembly It is the user s responsibility to observe and practice forklift safety rules Electrical Safety Wiring connections are required during assembly It is the user s...

Page 4: ...y Forklift Impact Wrench 19mm Socket Wrench 30mm Socket Wrench 5 lb Rubber Mallet Long pry bar 5 16 Allen wrench Standard Size Flat Head Screw Driver Small Flat Head Screw Driver Hammer Drill bit bit...

Page 5: ...osition where each side rail will be placed Forklift the side rails into position resting it on top of the blocks Position the side rails parallel to each other Space the rails 10 4 apart allowing roo...

Page 6: ...the Left Side Rail Cable Exit Hole Unbundle the three load cell cables in the rail Route the cables under the rail s top plates and out the cable exit hole then across the rear beam of the first weigh...

Page 7: ...s to the terminal block Securely tighten the strain relief collar to lock the cable into position b Feed Load Cell Cables 2 6 Into the Junction Box and Connect All Wires to the Terminal Blocks Followi...

Page 8: ...y lowered into the ramp tab foot holes c LOWER THE OTHER CORNER OF THE WEIGHING DECK INTO THE REMAINING LOAD CELL FOOT HOLE OF THE SAME RAMP Follow the instructions in Step b above to complete the att...

Page 9: ...Deck Top Access Panels Securely bolt down the access panels lightly tightening the four corner bolts on the panel then working from side to side tightening the other bolts Secrely tighten all bolts 16...

Page 10: ...Assembly Guide TS60 1010 Platform Scale Appendix i Figure 1a COMPLETE ASSEMBLY...

Page 11: ...Assembly Guide TS60 1010 Platform Scale Appendix ii Figure 1b WEIGHING DECK ASSEMBLY...

Page 12: ...Assembly Guide TS60 1010 Platform Scale Appendix iii Figure 1c RAMP MOUNTING TABS AND HANDLING PRECAUTIONS...

Page 13: ...Assembly Guide TS60 1010 Platform Scale Appendix iv Figure 2 PLACE SIDE RAILS ONTO WOOD BLOCKS Figure 3 PLACE THE FIRST DECK INTO POSITION AND LOOSELY BOLT TO SIDE RAILS...

Page 14: ...Assembly Guide TS60 1010 Platform Scale Appendix v Figure 4 ONLY USE SHORT BOLTS NEXT TO LOAD CELLS Figure 5 ROUTING THE LOAD CELL CABLES...

Page 15: ...Assembly Guide TS60 1010 Platform Scale Appendix vi Figure 6 PLACE THE SECOND DECK INTO POSITION AND LOOSELY BOLT TO SIDE RAILS...

Page 16: ...Assembly Guide TS60 1010 Platform Scale Appendix vii Figure 7 JUNCTION BOX Wiring Diagram...

Page 17: ...Assembly Guide TS60 1010 Platform Scale Appendix viii Figure 8 JUNCTION BOX Attached at Side Rail 1 Figure 9 ALIGN RAMP TAB TO WEIGHING DECK LOAD CELL FOOT...

Page 18: ...Assembly Guide TS60 1010 Platform Scale Appendix ix Figure 10 MOVE RAMP INTO POSITION UNDER WEIGHING DECK LOAD CELL FOOT Figure 11 FULLY ASSEMBLED SCALE...

Page 19: ...or logo or the serial number be removed or the product fail to be properly maintained or fail to function properly as a result of misuse abuse improper installation neglect improper shipping damage c...

Page 20: ......

Reviews: