T.A.C. 500

Design- Handsfree telephone with programmable

internal auto dial capability and remote control
of relays.

Capacity  -  24, 50, 125, 300, or 400 residents.

Capacity includes 1 to 4 digit directory code, 4
digit direct entry code, and up to 12 digit tele-
phone number for each resident.

System Security-  Program access code and

tamper code.

Dial Mode -  Allows active DTMF keypad after

dial out.

Site ID -  Programmable 4 digit code.
Call Length -  Unrestricted, or limited from 1 to

4 minutes.

Programming -  Directly on keypad or remotely

by DTMF tones.

Power -  120VAC/12VAC, 40VA, Class 2, trans-

former included.

Relay Ratings -

Primary Relay: 5 AMPS @ 30 VDC/250VAC;
1/8 HP 120VAC
Alarm Shunt Relay: 250ma @ 12VAC

Relay Activation -  Keypad direct entry, postal

lock box, push-to-exit button, or tenant.

Relay Output Duration -  Programmable;

momentary to 45 seconds, or latched.

Telephone Line -  Standard touch-tone or rotary.

Dedicated or extension line.

Mounting -  Surface, with flush or pedestal mount

options.

Construction  -PCB mounted in a high impact

plastic module.

Operating Temperature -   +32

°

 F  to  +120

°

 F

SPECIFICATIONS / FEATURES

SPECIFICATIONS / FEATURES

SPECIFICATIONS / FEATURES

SPECIFICATIONS / FEATURES

SPECIFICATIONS / FEATURES

Summary of Contents for T.A.C. 500

Page 1: ...255 Glider Circle Corona CA 92880 800 842 7444 Info trigonelectronics com www TrigonElectronics com March 1 2004 INSTALLATION and OPERATION INSTRUCTIONS Multi Number Telephone Entry System T A C 500...

Page 2: ...Deleting Telephone Numbers 7 Programming Entry Codes 7 Changing the Program Code 7 Deleting Entry Codes 7 Entering Access Cards 8 Deleting Cards 8 Programming Site ID Code 8 Programming Tamper Code 8...

Page 3: ...ident then grants or denies access The T A C 500 has a capacity of up to 400 telephone numbers and up to 400 personal entry codes and is PBX compatible It is constructed for rugged outdoor use The T A...

Page 4: ...e ground location on the terminal block This ground wire should go to a grounding rod or grounded metal conduit 5 Trigon recommends that an EMI filter Cornell Dubilier Model APF 1021 or equivalent be...

Page 5: ...Page 5 T A C 500 Figure 3 WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM 1 2 3 4 5 6 7 8 9 10 Input Power Main Relay Gnd Alarm Shunt Relay Telco...

Page 6: ...to answers This count is adjustable from 1 to 9 4 Enter the number that indicates the number of rings desired 3 For example Enter 1 for one 5 second interval Enter 2 for two 5 second intervals 10 seco...

Page 7: ...ns for Programming Telephone Numbers and enter the new number in place of the old one The old number will be overwritten D Programming Entry Codes Entry Codes make it possible for the resident to ente...

Page 8: ...ing the desired function code 5 Enter to exit Program Mode otherwise continue programming by entering the desired function code I Programming Site Identification Code In the case of multi unit install...

Page 9: ...part of the week i e Tuesday through Friday Note Military time format 24 hour clock is used in clock programming To program Secondary Relay do the following 1 Unit must be in Program Mode see section...

Page 10: ...keypad Otherwise the visitor may walk away leaving the unit active Shortly the loud off hook indicator tone from the telephone company will be heard for the remaining duration of the call length Latc...

Page 11: ...nit When it answers choose from the following 1 Enter 0 for touch tone echo test Unit will echo any touch tone you send with your phone 2 Press to escape from this test 3 Enter 1 for memory test One t...

Page 12: ...ice i e door strike RESIDENT CANNOT ACTIVATE STRIKE GATE 1 Tenant not pressing correct number on phone 2 Strike gate operator not wired correctly 3 Missing or incorrect power to strike or gate operato...

Page 13: ...nit capacity cccc 2 rrrr Verify phone number for Resident Code rrrr none listed 3 Verify Clock MM DD YY hh mm d none installed 4 Verify Relay One Schedule hhmm hhmm d d not set 5 Verify Secondary rela...

Page 14: ...ming Directly on keypad or remotely by DTMF tones Power 120VAC 12VAC 40VA Class 2 trans former included Relay Ratings Primary Relay 5 AMPS 30 VDC 250VAC 1 8 HP 120VAC Alarm Shunt Relay 250ma 12VAC Rel...

Page 15: ...Page 15 T A C 500...

Page 16: ...Page 16 T A C 500...

Reviews: