TROUBLE SHOOTING GUIDE

TROUBLE SHOOTING GUIDE

TROUBLE SHOOTING GUIDE

TROUBLE SHOOTING GUIDE

TROUBLE SHOOTING GUIDE

General:

Data between [ ] is a mandatory program key stroke
sequence.  Data between { } is to be supplied by the
programmer.  Unit responses are shown between ( ).

Legend:

d

Day of the week (1, 2,…7; Monday= 1)

DD

Date (01, 02,…31)

eeee

Entry Code (always use four digits)

hh

Hour (01, 02,…23)

iiii

Site ID Code (always use four digits)

mm

Minute (01, 02,…59)

MM

Month (01, 02,…12)

nnn nnnn Resident Phone Number (up to 14 digits)
pppp

Program Code

rrrr

Resident Code (may be 1, 2, 3, or 4 digits)

YY

Year (01, 02,…99)

The “star” key of the telephone

#

The “pound sign” key of the telephone

Tones returned by the unrogramming at
the Unit:

CONDENSED GUIDE TO USE and PROGRAMMING

CONDENSED GUIDE TO USE and PROGRAMMING

CONDENSED GUIDE TO USE and PROGRAMMING

CONDENSED GUIDE TO USE and PROGRAMMING

CONDENSED GUIDE TO USE and PROGRAMMING

NO DIAL TONE

1. Check (check fuse) input power at unit.  Should be

12 VAC.

2. Check that unit is properly grounded to a good

Earth ground.

3. Current starved.  Increase AC input wire size.

4. Remove power, wait 5 seconds, restore power.

Check for dial tone.

5. Check for phone line.  Voltages across terminals

should be 48-52 VDC (on hook), 6-12 VDC(off
hook).

6. Check VOLUME adjustment on PC board.

7. Check handset connections to PCB.

8. Verify that contacts and wires are clean and

tight.

CANNOT PROGRAM

1. Incorrect/lost program code.

2. Not entering “*” before program code.

3. Try ‘NO DIAL TONE’ troubleshooting

procedures.

4. Keypad damaged.  Check for vandalism.

5. Check that the Program Prom/Microprocessor is

fully seated.

LOSES MEMORY

1. Electrical noise on power line.  Install EMI/RFI

filter.

2. Excessive electrical noise from strike. Use low

current strike.

3. Unit transformer shared with another device (i.e.

door strike).

RESIDENT CANNOT ACTIVATE STRIKE/GATE

1. Tenant not pressing correct number on phone.

2. Strike/gate operator not wired correctly.

3. Missing or incorrect power to strike or gate

operator.

4. Current starved.  Increase wire size.

5. Tone may be too brief in duration (cordless

phones, etc.).

AC HUM IN SPEAKER

1. Phone wires running in same conduit as AC

power.

2. Unit not properly grounded.

3. Defective microphone.

RESIDENT CANNOT HEAR VISITOR

1. Defective handset/microphone.

2. Too much background or street noise.  Relocate

unit.

Feel free to contact our Tech Support Dept. (800)

842-7444 or (951) 371-1730

[email protected]

www.TrigonElectronics.com

Programming at the Unit:

Enter the Program Mode:  Acquire dial tone.

Press " *, Program Access Code".

You will hear two beeps.

Set Unit Parameters:

Press "#, 0", then;

{3} Set Resident Code Length (1 - 4 digits)

{3} Set Ring Count (1 - 9, 0= unlimited)

{3} Set Gate Interval (1 - 9 five second intervals,

0=1 second pulse)

{3} Set Call Length (1 - 4 minutes, 0= no time-

out)

{0} Set Dial Mode (1= Rotary, 0= Tone) (+{2}=

active DTMF keypad after dial out)

{0} Set Latch Enable Mode (0= none, 1= Relay

(

☎☎

)

Summary of Contents for MiniGuard IID Series

Page 1: ...ona CA 92880 951 371 1730 Facsimile 951 371 2592 www TrigonElectronics com November 15 2007 Multi Number PC Programmable Telephone Entry System INSTALLATION and PROGRAMMING INSTRUCTIONS 04A00103 SMT B...

Page 2: ...Telephone Numbers 7 Programming Entry Codes 7 Changing the Factory Program Code 7 Deleting Entry Codes 7 Entering Data Codes 8 Deleting Data Codes 8 Programming Site ID Code 8 Programming Tamper Code...

Page 3: ...PBX Analog Port compatible It is constructed for rugged outdoor use Its long lasting brushed finish stainless steel housing complements its thin design lines The Miniguard IID is available in surface...

Page 4: ...elays 1 and 2 are dry contact Form C type rated for 5 AMPS 30 VDC 250VAC 9 RS232 direct connect cable from computer Computer 9 pin RS232 pin 3 connects to terminal IN pin 2 connects to terminal OUT an...

Page 5: ...IID KEYPAD CONNECTION Microprocessor Mem ory 12VAC DC NO NC C 0 250 18AWG Shielded 250 t o 500 16AWG Shielded 500 14AWG Shielded Input Cable Size Door Strike Connections Voice Grade 24 to 48V 22AWG Sh...

Page 6: ...tory default settings may be changed to better suit your particular application If you decide to alter these settings follow the instructions below It is important that each programming step be taken...

Page 7: ...ng Entry Codes D Programming Entry Codes D Programming Entry Codes D Programming Entry Codes D Programming Entry Codes Entry Codes make it possible for the resident to enter a Code P I N number at the...

Page 8: ...h Mode is aborted 4 Press 2 to re enter Batch Mode or If the card has been successfully removed 5 Enter to exit Program Mode otherwise continue programming by entering the desired function code I Prog...

Page 9: ...ily on off action to happen within a certain part of the week i e Tuesday through Friday Note Note Note Note Note A military time format 24 hour clock is used in clock programming To program Output Re...

Page 10: ...rminate call press 7 Note During a call an inserted double beep tone will announce that the call will be auto terminated in 10 seconds Pressing an 8 will reset the timeout if additional time is requir...

Page 11: ...ST position for letter M Enter 4 3 key 4 THIRD position for letter I Enter 8 1 key 8 FIRST position for letter T Enter 4 2 key 4 SECOND position for letter H Enter 1 1 key 1 FIRST position for space E...

Page 12: ...next to the tenant s name on the LCD directory You will hear tenant answer Granting Visitor Entry Answer telephone and identify visitor You may choose from the following options fig 4 1 Enter 0 to ac...

Page 13: ...owing 1 Enter 0 for touch tone echo test Unit will echo any touch tone you send with your phone 2 Press to escape from this test 3 Enter 1 for memory test One tone good two tones bad 4 Enter 2 for tou...

Page 14: ...ts and wires are clean and tight CANNOT PROGRAM 1 Incorrect lost program code 2 Not entering before program code 3 Try NO DIAL TONE troubleshooting procedures 4 Keypad damaged Check for vandalism 5 Ch...

Page 15: ...Entry Code Press 1 eeee memory full Delete Entry Code Press 2 eeee already in memory Add Data Code Press 1 eeeee memory full Delete Data Code Press 2 eeeee already in memory Set Clock Optional Press...

Page 16: ...1 to 4 minutes Programming Directly on keypad or remotely by DTMF tones Power 120VAC 12VAC 40VA Class 2 trans former included Output Ratings Power Relays 5 AMPS 30 VDC 250VAC 1 8 HP 120VAC Alarm Shun...

Page 17: ...Page 17...

Reviews: