Tricor 530 Quick Start Manual Download Page 2

Figure 5 ... Changing fixed value settings

Figure 7 ... Statistical Analysis Graph

- two value settings

to display a Statistical

press Enter to toggle

Analysis graph ...

- multi-value settings

- from the SYSTEM STATUS

press Status to increment

  screen navigate to the

press Enter to decrement

  Statistics group and
  press Enter

- see lines at bottom of display for description of

which key(s) to use based on the

- select the View Stats by

currently selected parameter

  Prod ID menu item and
  press Enter

- select the desired Prod ID
  and press Enter

Figure 6 ... Changing numeric settings

- press numeric keys to change value

- press Enter to accept new value
- press Backspace to clear last key entered

- press Cancel to exit without changing value

- press Print to send statistical data results to the internal printer (the graph is not printed)

- up to 120 run results are displayed, if more are stored the latest 120 are displayed

- all stored runs for the selected Product ID are included in the calculations, even if not displayed
- oldest data is to the left, newest to the right. each dot represents one test run result

- Product ID's are selected through a menu that includes up to 9 ID's, if more are stored then an

additional menu item is displayed to allow user entry of an ID via the keypad

Figure 8 ... Stored Run - Graph

Figure 9 ... Stored Run - List

to display stored run data ...

- from the SYSTEM STATUS screen navigate to the Stored

Runs group and press Enter

- select the View Stored Runs menu item and press Enter

- first run displayed is last run stored (newest)

- display format graph (Fig 8) or list (Fig 9) per "Run Data

Display Format" setting

- press Print

- internal printout format per "Int Printout Format"
- if the external printer option is present then a menu

pops up to select where to print: "1 = Int  2 = Ext"

- scrolling through stored results

- press Enter to scroll to previous run (older) *
- press Status to scroll to next run (newer) *
- press "+/-" to scroll to 10th prev run (older) *

(Result string format = CTU / Slope 2)

- press "3" to scroll to 10th next run (newer) *

(Result string format = S2 / T1 / T2 and run has a Sample Description)

("-----" signifies ID enable = Off)

- scrolling will automatically rollover at memory boundaries

- scrolling through list format sample data

- if currently viewing newest and scroll "Next" past

- press Scroll Up/Down keys for single step scroll *

* holding down any scroll key switches to fast scroll mode:

memory boundary then oldest will be displayed

- press "6" key to page up through list *

- stored run scrolling - only the header data is displayed

- if currently viewing oldest and scroll "Prev" past

- press "9" key to page down through list *

- list scrolling - only one line of time, temp, slope is displayed

memory boundary then newest will be displayed

Figure 10 ... Printer Buttons (as viewed on unit)

Figure 11 ... Open paper access door

Figure 12 ... Insert new paper roll

Figure 13 ... Close and lock access door

- carefully pull access door lever (Fig 10, 11)

until door is released from its locked
position

mode button

- remove empty roll
- insert new roll, leave approx 2 cm (3/4 in)

paper feed

outside door (Fig 12)

button

- close door by carefully pressing the center

of door until door locks closed (Fig 13)

- a pink stripe at edge of paper signifies

Status LED

end of paper roll

- single flashes signify out of paper
- double flashes signify thermal printhead too

hot, allow printer to cool down

Figure 15 ... Keypad Buttons

Figure 16 ... Serial Comm Connectors (rear panel)

Figure 14 ... Power Entry Module (rear panel)

10th Next Run

Page Up (List)

USB (Type B) (used with UserApp530 and TMDAS PC programs)

Next Run

Scroll Up

Scroll Down

Previous Run

10th Prev Run

Page Down (List)

fuse access door (remove power

(hold any scroll key down for fast scroll mode)

RS-232 (RJ-11) (used with External Print / Plot option)

cord before opening)

Dimensions ......................................................... 27h x 47w x 38d cm

Temper Curve Graph Scales

Programmable Cooler Temperature ...................................... 321-420

10.5h x 16.5w x 15.0d inches

Temperature axis scale ............................. 14°C (28°F) (display, printouts)
Temperature axis baseline ... 14° to 32°C (56° to 92°F) (display, printouts)

External Print / Plot (includes dot matrix printer) ................... 321-421

Weight .......................................................................... 8.7kg (19 lbs)

Time axis scale .................................................. 5 min or 10 min (display)

per test run (printouts)

Data Acquisition Application (TMDAS) .................................. 150-124

Power Requirements ............................................ Universal AC Input

range 90 to 250 vac, 50 or 60 Hz

Self-Test ...................................................................... automatic on power up

1.7A @ 115vac (0.85A @ 230vac)

can also be run from menu

Internal Memory Storage ..................................... 165 five minute runs

Color TFT LCD Display ............................................. 16 user selectable colors

LED backlight

Sample Test Time .......................... 3 to 10 minutes (programmable)

320w x 234h pixels

40 characters (w) x 29 lines (h)

Sample Volume ....................................................... 11.0 mL (0.38oz)

PC Configuration Application ........................................... PC program used for

Sample Stabilization Time ....................................................... 30 sec

(UserApp530)

configuration setup

CTU Repeatability ................................................................. ± 0.5 ctu

RoHS Compliant ....................... EU Directives 2002/95/EC and 2005/618/EC

Cooler Stability ........................................................ ±0.06°C (±0.1°F)

Sample cup storage tube capacity ...................................................... 80 cups

Probe Heater Temperature Accuracy ....................... ±0.6°C (±1.0°F)

Temperature Measurement Sensitivity ............. ±0.003°C (±0.005°F)

Sample cups (box of 5000) .................................................................. 130-226

Temperature Measurement Range ........... -8° to 55°C (18° to 131°F)

Printer Paper roll (box of 24) ............................................................... 321-161

Ambient Operating Temperature Range ... 10° to 41°C (50° to 105°F)

Well cleaning tool ................................................................................ 130-245

Doc Num 321-403  Rev -

8

Statistical Data Viewing

6

5

Stored Run Viewing

Changing Parameter Values

TRICOR Systems, Inc.
1650 Todd Farm Drive

Elgin, IL 60123

1-847-742-5542

www.tricor-systems.com

---------------------------------------------- Supplies ----------------------------------------------

-------------------------------------------------------------------------------------------- Specifications --------------------------------------------------------------------------------------------

---------------------------------------- Options ----------------------------------------

------------------------------------------------------------------------------------------------- Changing Printer Paper Roll -------------------------------------------------------------------------------------------------

7

Reviews: