Figure 5 ... Changing fixed value settings
Figure 7 ... Statistical Analysis Graph
- two value settings
to display a Statistical
press Enter to toggle
Analysis graph ...
- multi-value settings
- from the SYSTEM STATUS
press Status to increment
screen navigate to the
press Enter to decrement
Statistics group and
press Enter
- see lines at bottom of display for description of
which key(s) to use based on the
- select the View Stats by
currently selected parameter
Prod ID menu item and
press Enter
- select the desired Prod ID
and press Enter
Figure 6 ... Changing numeric settings
- press numeric keys to change value
- press Enter to accept new value
- press Backspace to clear last key entered
- press Cancel to exit without changing value
- press Print to send statistical data results to the internal printer (the graph is not printed)
- up to 120 run results are displayed, if more are stored the latest 120 are displayed
- all stored runs for the selected Product ID are included in the calculations, even if not displayed
- oldest data is to the left, newest to the right. each dot represents one test run result
- Product ID's are selected through a menu that includes up to 9 ID's, if more are stored then an
additional menu item is displayed to allow user entry of an ID via the keypad
Figure 8 ... Stored Run - Graph
Figure 9 ... Stored Run - List
to display stored run data ...
- from the SYSTEM STATUS screen navigate to the Stored
Runs group and press Enter
- select the View Stored Runs menu item and press Enter
- first run displayed is last run stored (newest)
- display format graph (Fig 8) or list (Fig 9) per "Run Data
Display Format" setting
- press Print
- internal printout format per "Int Printout Format"
- if the external printer option is present then a menu
pops up to select where to print: "1 = Int 2 = Ext"
- scrolling through stored results
- press Enter to scroll to previous run (older) *
- press Status to scroll to next run (newer) *
- press "+/-" to scroll to 10th prev run (older) *
(Result string format = CTU / Slope 2)
- press "3" to scroll to 10th next run (newer) *
(Result string format = S2 / T1 / T2 and run has a Sample Description)
("-----" signifies ID enable = Off)
- scrolling will automatically rollover at memory boundaries
- scrolling through list format sample data
- if currently viewing newest and scroll "Next" past
- press Scroll Up/Down keys for single step scroll *
* holding down any scroll key switches to fast scroll mode:
memory boundary then oldest will be displayed
- press "6" key to page up through list *
- stored run scrolling - only the header data is displayed
- if currently viewing oldest and scroll "Prev" past
- press "9" key to page down through list *
- list scrolling - only one line of time, temp, slope is displayed
memory boundary then newest will be displayed
Figure 10 ... Printer Buttons (as viewed on unit)
Figure 11 ... Open paper access door
Figure 12 ... Insert new paper roll
Figure 13 ... Close and lock access door
- carefully pull access door lever (Fig 10, 11)
until door is released from its locked
position
mode button
- remove empty roll
- insert new roll, leave approx 2 cm (3/4 in)
paper feed
outside door (Fig 12)
button
- close door by carefully pressing the center
of door until door locks closed (Fig 13)
- a pink stripe at edge of paper signifies
Status LED
end of paper roll
- single flashes signify out of paper
- double flashes signify thermal printhead too
hot, allow printer to cool down
Figure 15 ... Keypad Buttons
Figure 16 ... Serial Comm Connectors (rear panel)
Figure 14 ... Power Entry Module (rear panel)
10th Next Run
Page Up (List)
USB (Type B) (used with UserApp530 and TMDAS PC programs)
Next Run
Scroll Up
Scroll Down
Previous Run
10th Prev Run
Page Down (List)
fuse access door (remove power
(hold any scroll key down for fast scroll mode)
RS-232 (RJ-11) (used with External Print / Plot option)
cord before opening)
Dimensions ......................................................... 27h x 47w x 38d cm
Temper Curve Graph Scales
Programmable Cooler Temperature ...................................... 321-420
10.5h x 16.5w x 15.0d inches
Temperature axis scale ............................. 14°C (28°F) (display, printouts)
Temperature axis baseline ... 14° to 32°C (56° to 92°F) (display, printouts)
External Print / Plot (includes dot matrix printer) ................... 321-421
Weight .......................................................................... 8.7kg (19 lbs)
Time axis scale .................................................. 5 min or 10 min (display)
per test run (printouts)
Data Acquisition Application (TMDAS) .................................. 150-124
Power Requirements ............................................ Universal AC Input
range 90 to 250 vac, 50 or 60 Hz
Self-Test ...................................................................... automatic on power up
1.7A @ 115vac (0.85A @ 230vac)
can also be run from menu
Internal Memory Storage ..................................... 165 five minute runs
Color TFT LCD Display ............................................. 16 user selectable colors
LED backlight
Sample Test Time .......................... 3 to 10 minutes (programmable)
320w x 234h pixels
40 characters (w) x 29 lines (h)
Sample Volume ....................................................... 11.0 mL (0.38oz)
PC Configuration Application ........................................... PC program used for
Sample Stabilization Time ....................................................... 30 sec
(UserApp530)
configuration setup
CTU Repeatability ................................................................. ± 0.5 ctu
RoHS Compliant ....................... EU Directives 2002/95/EC and 2005/618/EC
Cooler Stability ........................................................ ±0.06°C (±0.1°F)
Sample cup storage tube capacity ...................................................... 80 cups
Probe Heater Temperature Accuracy ....................... ±0.6°C (±1.0°F)
Temperature Measurement Sensitivity ............. ±0.003°C (±0.005°F)
Sample cups (box of 5000) .................................................................. 130-226
Temperature Measurement Range ........... -8° to 55°C (18° to 131°F)
Printer Paper roll (box of 24) ............................................................... 321-161
Ambient Operating Temperature Range ... 10° to 41°C (50° to 105°F)
Well cleaning tool ................................................................................ 130-245
Doc Num 321-403 Rev -
8
Statistical Data Viewing
6
5
Stored Run Viewing
Changing Parameter Values
TRICOR Systems, Inc.
1650 Todd Farm Drive
Elgin, IL 60123
1-847-742-5542
www.tricor-systems.com
---------------------------------------------- Supplies ----------------------------------------------
-------------------------------------------------------------------------------------------- Specifications --------------------------------------------------------------------------------------------
---------------------------------------- Options ----------------------------------------
------------------------------------------------------------------------------------------------- Changing Printer Paper Roll -------------------------------------------------------------------------------------------------
7