Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008
P a g e
8 | 20
Mounting the On/Off Motor Switch
The On/Off Switch that controls the motor has been shipped loose, and not attached onto the system.
The power cord connected to the pump has approximately 6 feet before the On/Off Switch. Once the
best place for the On/Off switch is determined, remove the double-sided tape strip on the backside of
the electrical box and mount the On/Off Switch. The On/Off switch is shown below mounted to the
Dispensing Nozzle Bar; however, the switch can be mounted in any location.
NOTE: The electrical cord connecting the On/Off switch to the
motor is not shown in the image above
Powering the Motor/Pump
The electric motor on the Pump Stack has a full load amperage of 17.2A and a separate 20 Amp circuit is
recommended for each Pump Stack. Once the correct outlet has been installed by a certified electrician,
making sure the On/Off switch is in the OFF position, place the NEMA 5-20P plug into the receptacle.
The power cord from the electric motor has approximately 14 feet of cord until the plug.
ON/OFF Switch