background image

MA RKER

6

No.

Dis.

Loss

Ref.

dB/km C.Loss

A-B: 000.000km

0.000dB

0.000dB/km

A   0.000km

B   0.940km

4.00dB/div

X

Y

0.200km/div

201001.sor

Measure Info:     1310nm      2.0km       10ns

1/6

3/6

4/6

5/6

0.000

4.301

5.589

18.712

0.00

0.12

-0.05

-.--

-.--

-.--

-.--

-.--

-51.74

-54.67

-41.03

0.28

0.22

0.00

1.18

4.07

2/6

0.940

0.08

-51.74

0.24

0.26

2020-10-01    THU    21:25

After testing or open the saved waveform, then event list shows, Max. 5 

events listed, if more, press “        ”“        ” to view, and the cursor will be 

located in selected event, short press “           ” to choose the cursor, and 

scale current waveform by pressing combined buttons.

Mini OTDR--Waveform Analysis

X-axis zoom in

A

2

3

   0.000km

  10.057km

Y-axis zoom in

A

   0.000km

1

  10.057km

2

3

Summary of Contents for TB-700

Page 1: ...OTDR Testing Platform TB 700 User s Manual 2020 10 01 THU 10 08 Mini OTDR OPM Loss Test OLA SE Distance Test Sequence Test OLS System Settings...

Page 2: ...Avoiding condensation Sudden changes in temperature should be avoided Do not use the device immediately after moving the device from the cold area to the hot area or when the room suddenly heats up b...

Page 3: ......

Page 4: ...1 HOST OPM RJ 45 cable test module VFL LED light 3 5 inch LCD RJ 45 test Type C Power Bank OTDR OLS...

Page 5: ...nterface 4 Control VFL ON GLINT OFF and press 2s to turn on off LED light 5 Zoom in out the OTDR testing waveform combining with Navigation and ESC buttons 6 Long press to turn on off the device If OF...

Page 6: ...gs ENTE R 3 Battery charging status VFL LED light USB After booting main menu shows in default Press Navigation buttons to select the function module then press button to enter into the corresponding...

Page 7: ...0 000 4 301 5 589 18 712 0 00 0 12 0 05 51 74 54 67 41 03 0 28 0 22 0 00 1 18 4 07 2 6 0 940 0 08 51 74 0 24 0 26 2020 10 01 THU 21 25 File name Waveform region Scale Event List Measurement info Dist...

Page 8: ...ss button to enter into measurement setting interface Under OTDR or measurement setting interface press button to start measurement Press again to stop the testing during the measurement If Real time...

Page 9: ...03 0 28 0 22 0 00 1 18 4 07 2 6 0 940 0 08 51 74 0 24 0 26 2020 10 01 THU 21 25 After testing or open the saved waveform then event list shows Max 5 events listed if more press to view and the cursor...

Page 10: ...PD_074 0002 Rev 210202...

Page 11: ...v h b j n k m l 1 q Space Enter 025404 20km After testing press to save the result and will pop up soft keyboard to edit the name If Auto name is ON in system setting then file will be auto named whe...

Page 12: ...4dB 9 464dB 10 0003km OLA SE 120 20431km 120 20431km 120 20431km 120 20431km EventList 2020 10 01 THU 21 25 8 1 2 5 3 6 4 1 Measurement overview 2 Details of selected event 3 Location of each event 4...

Page 13: ...5 000dB Press key ENTER to edit settings 2020 10 01 THU 21 25 S ET TING ENTE R SCA N 9 In OLA SE interface press button to enter into Settings and press and Navigation buttons to set the parameters In...

Page 14: ...2 6 No Type Dis Len Loss Press button to check the event list and press button to save the data If no testing press button to enter the file list then press button to open the folder or file Press but...

Page 15: ...reference value Press to the OPM setting interface Auto If ON then OPM can identify the current wavelength in fiber automatically Freq ID Set ON OFF to identify the frequency or not Offset settings I...

Page 16: ...310 1550nm and modulation among continuous signal 270Hz 1kHz 2kHz 1kHz Blink 2kHz Blink OLS Operate according to the prompts Change modulation WAVELENGTH 800 1700nm MAXIMUM OUTPUT 1mW CLASS II LASER P...

Page 17: ...OLS and set the reference value then connecting the under test fiber and check its loss value Laser radiation Do not look directly to the laser Operate according to the prompts dB mW 82 790 55 540 131...

Page 18: ...the measurement as prompts in the bottom Distance test Support to test the length of common CAT5 6 cable Sequence test To check the connection quality of RJ45 terminations whether in right sequence o...

Page 19: ...all files in the device If with TF card delete all files in the SD card USB Connection Connect the device to PC via USB cable to view internal or TF card saved data OTG Set whether to view the data i...

Page 20: ......

Reviews: