Battery energy detect

        Battery energy has five indicators:

                  Remain 80%---100%

   Remain 60%---80%

                  Remain 40%---60%
                  
                  Remain 20%---40%

                  Remain less than 20%

        If the energy is too low, the beep will be on and the device will 

auto power off.  When you plug in the AC adapter and rechargeable 

batteries inside, the screen will show  the charging icon on upper 

right corner.

Select Function

PON

OPM

VFL

Summary of Contents for EPN90

Page 1: ...USER S GUIDE PON OPTICAL POWER METER English English...

Page 2: ......

Page 3: ...ASER PRODUCT Precautions for Use Use batteries At the same time can not use differentstyle or different capacitancebatteries And only chargethe rechargeable batteries Avoiding condensation problems As...

Page 4: ...ndard Host Manual Calibration Certificate Optional AC DC Adaptor If any accessory is short pleaserelate with the dealer ASAP Threshold REF dBm dB F P mode ReCall Save Enter 2S PERM USER S GUIDE PON OP...

Page 5: ...14 15 16 1 ONT 1310nm input connector 2 OLT Video 1490 1550nm input connector 3 LCD 4 Power Key 5 F P mode Key PASS WRNG FAIL 6 VFL key 7 Unit Key dBm dB 8 Up Key 9 Threshold Key 10 Save Key 11 Down K...

Page 6: ...4 1 Press and pushdown 2 Open the lid 3 Place the batteries 4 Close the lid and push up Set batteries Warning At the same time can not use differentstyle and different capacitancebatteries...

Page 7: ...itter ONT OLT Threshold REF dBm dB F P mode ReCall Save Enter 2S PERM Threshold REF dBm dB F P mode ReCall Save Enter 2S PERM Data Networks Analyser IXIA Smartbits Optical Splitter Lamda Demultiplexer...

Page 8: ...key to turn on the device with auto power off After 10 minutes nokey pressed it will auto power off Press the key for 2 seconds when turn on the device the auto power off will be cancelled and the LC...

Page 9: ...hreshold REF dBm dB F P mode ReCall Save Enter 2S PERM It can test the signal of 1310 1490 1550nm and show its power at the same time HI and LOW mean the result is out of the testing range Select Func...

Page 10: ...B F P mode ReCall Save Enter 2S PERM PASS WRNG FAIL Alarm depends on the threshold the user set key Open or close the alarm function PASS WRNG FAIL On LCD there are warning words beside theresults Tx...

Page 11: ...r 2S PERM key It will show you the reference value you stored before then turn the unit to dB Keep pressing it for 2 seconds you can save current value as a new reference key Change the unit dBm dB No...

Page 12: ...shold REF dBm dB F P mode ReCall Save Enter 2S PERM Press the key user can shift theinterface The upper right picture shows the threshold set interface User can set these 10 thresholds Please see page...

Page 13: ...of any data see figure 3 How to understand the threshold 1 Each wavelength has its threshold 2 If the current value Max Value the alarm of corresponding wavelength will be FAIL 3 If the current value...

Page 14: ...ng interface ReCall Save ReCall Save ReCall Save 0001 0002 0003 0004 0005 0006 0007 0008 0009 0010 1310nm 0 00 0 00 0 00 0 00 0 00 0 00 0 00 0 00 0 00 0 00 1490nm 0 00 0 00 0 00 0 00 0 00 0 00 0 00 0...

Page 15: ...B Threshold change the wavelength 850 1300 1310 1490 1550 1625nm REF Enter press to check the REF value press for 2 seconds to save the current value as a new REF value Threshold REF dBm dB F P mode R...

Page 16: ...5nm 1625nm 1625nm 1625nm 1625nm 1625nm 1625nm 1625nm 1625nm 0 00 0 00 0 00 0 00 0 00 0 00 0 00 0 00 0 00 0 00 11 12 13 14 15 16 17 18 19 20 1625nm 1625nm 1625nm 1625nm 1625nm 1625nm 1625nm 1625nm 1625...

Page 17: ...Enter Enter 2S PERM VFL Mode OPTIONAL When turn on the device press key to select VFL mode and press key to enter the visual fault locator mode In VFL mode press key can change the light status to be...

Page 18: ...tors Remain 80 100 Remain 60 80 Remain 40 60 Remain 20 40 Remain less than 20 If the energyis too low the beep will be on and the device will auto power off When you plug in the AC adapter andrecharge...

Page 19: ...ng the battery indication on LCD will flash After charging fully the indication will stop flashing and show full Don t chargefor more than 24 hours If charging whileusing the device the time will be l...

Page 20: ...eries Common malfunction Described Described Malfunction cause Malfunction cause Handle way Handle way Display the messy code Reset is incorrect Reset Operation do not have reaction Program is disorde...

Page 21: ...n of 1550nm bands Isolation of 1490nm bands Auto off Power supply Storage Temp Operating Temp Battery life Optic type Measurement of 1550nm Measurement of 1550nm Pass band Pass band Max permitted inpu...

Page 22: ...alibration Wavelength Model Option Model Option Standard V01 V10 V15 V20 V25 T M C 650 20nm 25mW 2 5mmUPP 0 01dB 1mW 0 2dB 10mW 2 70dBm 8dBm 60dBm 18dBm 50dBm 26dBm InGaAs FC PC 2 5mm UPP 700 1700nm 8...