MOD

Laser

ON

VFL

ID

Optical Laser Source

>2s PERM

9

    Press  "   

ID

     "  to open the function of wavelength 

identification, on the LCD, it will displays  "ID " , then the 

optical power meter which also has this function can 

identify the current wavelength in fiber, and the power 

meter will shift to the same wavelength automatically.

    Press again this key to close the function.

WAVE ID

ID

1Hz

PERM

GLINT

VLS

nm

MOD

Laser

ON

VFL

ID

Optical Laser Source

>2s PERM

10

Laser Source On/Off

    Press the key to turn on/off the laser source 

output. "                "  

.

on the LCD means laser 

output off

Laser

ON

1Hz

PERM

GLINT

VLS

Summary of Contents for AOP100

Page 1: ...USER S GUIDE English Handheld measuring instrument Optical power meter Optical laser source Optical multi meter English English R R TriBrer...

Page 2: ......

Page 3: ...USER S GUIDE English Handheld measuring instrument Optical power meter Optical laser source Optical multi meter English English...

Page 4: ......

Page 5: ...Optical Power Meter USER S GUIDE English...

Page 6: ...can use a disposable alkaline battery or recharg eable battery and can not be mixed with different types ordifferent capacity batteries Only rechargeable batteries can be charged Avoiding condensatio...

Page 7: ...Host Bag 2 FC SC Adapter Manual Optional Charging Standard REF Unit Save VFL Optical Power Meter 2s PERM...

Page 8: ...connector 1 VFL connector optional 4 OPM wavelength shift WAVE ID key 5 VFL on off key 6 Reference check set key 7 Unit shift key 8 USB 9 Power backlight key 10 Data save recall key Description REF Un...

Page 9: ...4 1 Press and push up 2 Open the lid 3 Install the batteries 4 Push down and press Install the Batteries...

Page 10: ...Auto Power Off Press the power key to turn on the device with auto power off After 10 minutes no key pressed it will auto power off Press power key for 2 seconds when turn on the device the auto powe...

Page 11: ...REF Unit Save VFL Optical Power Meter 2s PERM 6 2s PERM Backlight When the device power on press the power key to turn on or turn off the backlight dBm PERM nm GLINT VLS...

Page 12: ...VFL Optical Power Meter 2s PERM 7 Wavelength Select When testing you must select the right wavelength Press the key for shifting the wavelength from 850nm 1300nm 1310nm 1490nm 1550nm 1625nm dBm PERM...

Page 13: ...REF Unit Save VFL Optical Power Meter 2s PERM WAVE ID optional dBm PERM nm GLINT VLS Long press to turn on the WAVE ID and display at the same time Long press again to exit the WAVE ID 8...

Page 14: ...RM 9 Unit Select Unit Press the key for shifting the unit from dBm mW uW after pressing dB After power off it shift to the current unit will be saved mW uW 1mW 1000uW 1uW 1000nW dBm dBm 10 log mW dB d...

Page 15: ...ess key to check the reference value you set last time And if keep pressing for 2 seconds you can store the current dBm as a new reference value Then itautomatically shift to dB dB REF dBm You can sto...

Page 16: ...ve VFL Optical Power Meter 2s PERM 11 Data Storage S P hort press key to check the data storage ress and to change previous next record Long press key to save current value Save dBm PERM Save Save SAV...

Page 17: ...Save VFL Optical Power Meter 2s PERM 12 GLINT VLS press the VFLkey to shift the conditions on glint off The device can be built in an optional VFLmodule Visual Fault Locator optional VFL dBm PERM nm G...

Page 18: ...REF Unit Save VFL Optical Power Meter 2s PERM 13 Battery Energy Detect Sufficient power More power Less power Insufficient battery power dBm PERM nm GLINT VLS...

Page 19: ...n LCD will flash After charging fully the indication will stop flashing and show full Don t charge for more than 48 hours If charging while using the device the time will be longer The rechargeable ba...

Page 20: ...1dB 40 50dBm 0 1dB 0 2dB 2 InGaAs FC or SC 2 5mm UPP Yes Yes 650nm 1mW or 10mW 2 5mm UPP AAX3 160H 10 50 90 RH 20 60 90 RH 168mm 95mm 38mm 330g Measuring range Calibrated wavelengths Resolution Connec...

Page 21: ...Optical Laser Source USER S GUIDE English...

Page 22: ...can use a disposable alkaline battery or recharg eable battery and can not be mixed with different types ordifferent capacity batteries Only rechargeable batteries can be charged Avoiding condensatio...

Page 23: ...2 Host Bag Manual Optional Charging Standard MOD Laser ON VFL ID Optical Laser Source 2s PERM...

Page 24: ...tor 1 VFL connector optional 4 Laser source wavelength shift key 5 VFL on off key 6 Laser source modulation key 7 Laser source WAVE ID key 8 USB 9 Power backlight key 10 Laser source on off key Descri...

Page 25: ...4 1 Press and push up 2 Open the lid 3 Install the batteries 4 Push down and press Install the Batteries...

Page 26: ...Power key to turn on the device with auto power off After 10 minutes no key pressed it will auto power off Press power key for 2 seconds when turn on the device the auto power off will be cancelled an...

Page 27: ...MOD Laser ON VFL ID Optical Laser Source 2s PERM 6 2s PERM Backlight When the device power on press the power key to turn on or turn off the backlight 1Hz PERM GLINT VLS nm...

Page 28: ...MOD Laser ON VFL ID Optical Laser Source 2s PERM 7 Wave Select 1Hz PERM GLINT VLS nm Press key to change the wavelength...

Page 29: ...MOD Laser ON VFL ID Optical Laser Source 2s PERM 8 1KHz 2KHz 270Hz Modulation Select Press the key to shift from CW 270Hz 1KHz 2KHz MOD MOD 1Hz PERM GLINT VLS nm...

Page 30: ...identification on the LCD it will displays ID then the optical power meter which also has this function can identify the current wavelength in fiber and the power meter will shift to the same wavelen...

Page 31: ...MOD Laser ON VFL ID Optical Laser Source 2s PERM 10 Laser Source On Off Press the key to turn on off the laser source output on the LCD means laser output off Laser ON 1Hz PERM GLINT VLS...

Page 32: ...ON VFL ID Optical Laser Source 2s PERM 11 GLINT VLS press the VFLkey to shift the conditions on glint off The device can be built in an optional VFLmodule Visual Fault Locator optional VFL 1Hz PERM GL...

Page 33: ...MOD Laser ON VFL ID Optical Laser Source 2s PERM 12 Battery Energy Detect 1Hz PERM GLINT VLS nm Sufficient power More power Less power Insufficient battery power...

Page 34: ...battery to be shortened When charging the battery indication on LCD will flash After charging fully the indication will stop flashing and show full Don t charge for more than 48 hours If charging whil...

Page 35: ...1490nm 1625nm DFB 50H 650nm 168mm 95mm 38mm 330g OP Adapter Power supply Auto power off Size Weight Battery life VFL part Wavelength Output power Connector Wavelength Output power Laser type Frequenc...

Page 36: ...15...

Page 37: ...Optical Multi Meter USER S GUIDE English...

Page 38: ...can use a disposable alkaline battery or recharg eable battery and can not be mixed with different types ordifferent capacity batteries Only rechargeable batteries can be charged Avoiding condensatio...

Page 39: ...2 Host Bag FC SC Adapter Manual Optional Charging Standard MOD REF Unit Save Laser ON VFL Optical Multi Meter 2s PERM...

Page 40: ...ey 6 OPM unit shift key 7 OPM reference check set key 9 Laser source wavelength shift key 10 Laser source connector 11 USB 12 Power backlight key 13 OPM data save recall key 14 Laser source on off key...

Page 41: ...4 1 Press and push up 2 Open the lid 3 Install the batteries 4 Push down and press Install the Batteries...

Page 42: ...ower key to turn on the device with auto power off After 10 minutes no key pressed it will auto power off Press Power key for 2 seconds when turn on the device the auto power off will be cancelled and...

Page 43: ...MOD REF Unit Save Laser ON VFL Optical Multi Meter 2s PERM 6 2s PERM Backlight When the device power on press the power key to turn on or turn off the backlight dBm PERM nm 1310nm 1KHz GLINT VLS...

Page 44: ...VFL Optical Multi Meter 2s PERM 7 OPM Wavelength Select When testing you must select the right wavelength Press the key for shifting the wavelength from 850nm 1300nm 1310nm 1490nm 1550nm 1625nm dBm PE...

Page 45: ...F Unit Save Laser ON VFL Optical Multi Meter 2s PERM dBm PERM nm 1310nm 1KHz GLINT VLS OPM WAVE ID optional Long press to turn on the WAVE ID and display at the same time Long press again to exit the...

Page 46: ...OPM Unit Select mW uW 1mW 1000uW 1uW 1000nW dBm dBm 10 log mW dB dB dBm REF Unit dBm PERM nm 1310nm 1KHz GLINT VLS dBm mW nW REF Unit Press the key for shifting the unit from dBm mW uW after pressing...

Page 47: ...or 2 seconds you can store the current dBm as a new reference value Then itautomatically shift to dB dB dBm REF You can store the REF value for each wave REF MOD REF Unit Save Laser ON VFL Optical Mul...

Page 48: ...Laser ON VFL Optical Multi Meter 2s PERM OPM Data Storage Save dBm PERM Save Save S P hort press key to check the data storage ress and to change previous next record Long press key to save current v...

Page 49: ...MOD REF Unit Save Laser ON VFL Optical Multi Meter 2s PERM Laser Source On Off Press the key to turn on off the laser source output Laser ON dBm PERM nm 1310nm 1KHz GLINT VLS 12...

Page 50: ...00nm 1310nm 1490nm 1550nm 1625nm Laser Source Wavelength Select WAVE ID Short press the key to shift the wavelength Long press 2s the key to turn on WAVE ID function the wavelength glints on LCD Long...

Page 51: ...MOD REF Unit Save Laser ON VFL Optical Multi Meter 2s PERM 14 1KHz 2KHz 270Hz Laser Source Modulation Select Press the key to shift from CW 270Hz 1KHz 2KHz MOD MOD dBm PERM nm 1310nm 1KHz GLINT VLS...

Page 52: ...e Laser ON VFL Optical Multi Meter 2s PERM 15 GLINT VLS press the VFLkey to shift the conditions on glint off The device can be built in an optional VFLmodule Visual Fault Locator optional VFL dBm PER...

Page 53: ...MOD REF Unit Save Laser ON VFL Optical Multi Meter 2s PERM 16 Battery Energy Detect dBm PERM nm 1310nm GLINT VLS Sufficient power More power Less power Insufficient battery power...

Page 54: ...the battery to be shortened When charging the battery indication on LCD will flash After charging fully the indication will stop flashing and show full Don t charge for more than 48 hours If charging...

Page 55: ...s 270Hz 1KHz 2KHz FC PC or customize 850nm 10dBm 1300nm 1310nm 1550nm 1490nm 1625nm 6dBm 850nm 1300nm 1310nm 1550nm FP 1490nm 1625nm DFB 650nm FC or SC 2 5mm UPP Yes 1mW or 10mW Connector Wavelength O...

Page 56: ...19 Detailed 50H 168mm 95mm 38mm 330g Size Weight Power supply Battery life AAX3 10 50 90 RH 20 60 90 RH Operating temp Storage temp...

Page 57: ...20...

Page 58: ......

Page 59: ......

Page 60: ...P N40331 Rev 1005...